On the Effect of Tube Attenuation on Measuring Water Vapor Flux Using a Closed-path Hygrometer (폐회로 습도계를 이용한 수증기 플럭스 관측시관의 감쇠 효과에 관하여)

  • Hong Jinkyu;Kim Joon;Choi Taejin;Yun Jin-il;Tanner Bert
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.3
    • /
    • pp.80-86
    • /
    • 2000
  • Eddy covariance method is widely used in measuring vertical fluxes of mass and energy between the atmosphere and the biosphere. In this method, scalar concentration is measured with either open-path or closed-path sensors. For the latter, fluctuations of scalar concentration are attenuated as the sample travels through a long tube, resulting in flux loss. To quantify this tube attenuation, water vapor concentrations measured with both closed-path and open-path sensors were analyzed. Our statistical analysis showed that the power spectral density obtained from the closed-path sensor was different from that from the open-path sensor in the frequency range of > 0.5 Hz. The loss of water vapor flux due to tube attenuation was < 5% during midday. At nighttime, however, the flux loss increased significantly because of the low wind speeds and the weak turbulence sources. Theoretical calculation for the tube attenuation showed a small bias in high frequency range probably because of the interaction of sticky water vapor with a tube wall.

  • PDF

A Study of MTTF improvement of Thermal Device cryogenic-cooler (열상장비 냉각기의 MTTF 개선연구)

  • Jung, Yunsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.252-257
    • /
    • 2018
  • In this paper, we propose a mean time to failure (MTTF) to improve the solution for a cryogenic cooler, which is an important part of a cooled thermal device. Common electronic devices have a high possibility of failure due to various environmental factors, such as temperature and humidity. But some special devices (such as thermal devices) are designed to overcome environmental factors. The most affected part of a cooled thermal device's MTTF is the cryogenic cooler. The MTTF of a cryogenic cooler is affected by the device's internal heat. Therefore, if the device's internal heat is reduced, the cryogenic cooler's MTTF increases. From the present device's internal heat simulation, we analyze the improvement method of the device. The proposed improvement method's effectiveness is verified by simulation and MTTF calculation.

Enhancement of Faded Images Using Integrated Compensation Coefficients Based on Multi-Scale Gray World Algorithm (다중크기 회색계 알고리즘 기반의 통합된 보정 계수를 이용한 바랜 영상 개선)

  • Kyung, Wang-Jun;Kim, Dae-Chul;Ha, Yeong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.8
    • /
    • pp.459-466
    • /
    • 2014
  • Fading effect of old pictures and printings is shown up differently according to the ink property, temperature, humidity, illuminants, and so on. Faded image enhancement techniques based on illuminant estimation are proposed such as the gray world algorithm and white patch retinex methods. However, conventional simple operators are not suitable for enhancing faded images because partial fading effect is appeared differently. Thus, this paper presents a color enhancement algorithm based on integrating correction coefficients for faded images. First, the proposed method adopts local process by using multi-scale average mask. The coefficients for each multi-scale average mask are obtained to apply the gray world algorithm. Then, integrating the coefficients with weights is performed to calculate correction ratio for red and blue channels in the gray world assumption. Finally, the enhanced image is obtained by applying the integrated coefficients to the gray world algorithm. In the experimental results, the proposed method reproduces better colors for both wholly and partially faded images compared with the previous methods.

Development of Predication Model of Early-Age Concrete Strength by Maturity Concept (성숙도 개념을 이용한 콘크리트 초기강도 예측 모델 개발 연구)

  • 오병환;이명규;홍경옥;김광수
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.3
    • /
    • pp.197-207
    • /
    • 1996
  • Maturity is expressed as the integral of time and temperature of concrete above a datum temperature. The maturity concept proposes that concrete of the same mix at the same maturity has the same strength, whatever combination of temperature and time makes up that maturity. In this study, the Nurse-Saul function which was proposed to account for the effects of temperature and time on strength developrnent is used in computing maturity. After existing various functions are considered to relate concrete strength to the maturity value, new strength-maturity function is proposed. Tests ;ire conducted in order to determine d datum temperature and compare prechction value with measured concrete strength. The constants in proposed prediction equation are determined from test results, and the equation is adopted to predict the strength of slab. The slab was cast in the laboratory from the same batch of mold, and cores are cut from slab in order to estimate the actual strength. These values are used to compare with predicted value. The present study allows more realistic determination of early-age strength of concrete and can be efficiently used to control the quality in actual construction.

Decontamination of Chemical Warfare Agent Simulants using Vapor-phase Hydrogen Peroxide (과산화수소 증기를 이용한 유사화학작용제의 제독)

  • Kim, Yun-Ki;Yoo, Hyun-Sang;Kim, Min-Cheol;Hwang, Hyun-Chul;Ryu, Sam-Gon;Lee, Hae-Wan
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.360-365
    • /
    • 2014
  • Vapor-phase hydrogen peroxide(VPHP) has been used as a sterilant in the field of medical and pharmaceutical application due to low corrosive than chlorine contained sterilant. In addition, it is well known that VPHP is effective for decontamination of chemical warfare agents by adding ammonia gas. In this study, the decontamination efficiency was confirmed about CEPS, DFP and dimethoate as simulants of HD, GD and VX using VPHP respectively. For this purpose, VPHP generated from self configured device was injected into decontamination chamber and maintained for reaction time. After the decontamination, the residues are analyzed by GC/MS and decontamination efficiency was calculated. Through by-product for each simulants, the similarities in reaction mechanism of chemical warfare agents were confirmed. CEPS was completely decontaminated at 30% relative humidity within 60 min. By adding ammonia gas, DFP and dimethoate were completely decontaminated within 30 and 150 min respectively.

Performance Analysis of a Desiccant Rotor for Rotational Period in a Desiccant Cooling System (제습냉방시스템의 제습로터 회전주기변화에 따른 제습성능해석)

  • Pi, Chang-Hun;Kang, Byung-Ha;Chang, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.523-531
    • /
    • 2012
  • The performance simulation of a desiccant rotor, which is a core component of a desiccant cooling system, was conducted on the basis of a theoretical solution of the heat and mass transfer process in the rotor. The simulation model was validated by comparing simulation results with experimental data; reasonable agreement was observed. The effect of the rotation speed on the performance of the desiccant rotor was investigated for various operation conditions: temperature (50 to $70^{\circ}C$), humidity ratio (0.01 to 0.02 kg/kg DA), and flow rate of regeneration air. The optimum rotation speed was determined from the maximum moisture removal capacity (MRC) of the desiccant rotor, and it was found to vary with the operation conditions. Further, the correlation for the optimum rotation speed was determined by regression analysis.

Design and Implementation of Low Power Touch Screen Controller for Mobile Devices (모바일용 저전력 터치 스크린 제어 회로 설계 및 구현)

  • Park, Sang-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.279-283
    • /
    • 2012
  • In is paper, we design and implement the low power, high speed touch screen controller that calculates and outputs the coordinate of touch point on the touch screen of mobile devices. The system clock is 10HMz, the number of input channels is 21, standby current is $20{\mu}A$, dynamic range of input is 140pF~400pF and the response time is 0.1ms/frame. It contains the power management unit for low power, automatic impedance calibration unit in order to adapt to humidity, temperature and evaluation board, adjacent key and pattern interference suppression unit, serial interface unit of I2C and SPI. The function and performance is verified by using FPGA and $0.18{\mu}m$ CMOS standard process. The implemented touch screen is designed for using in the double layer ITO(Indium Thin Oxide) module with diamond pattern and single layer ITO module for cost-effective which are applied to mobile phone or smart remote controller.

The Position Sensorless Control of SRG using the Instantaneous Flux (순시자속을 이용한 위치센서 없는 SRG의 운전)

  • 김영조;오승보;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.472-481
    • /
    • 2002
  • In this paper, the instantaneous flux Is applied to control the position of the SRG (Switched Reluctance Generator) without position sensor. The position information of the rotor is required in the drive of SRG. These data are generally obtained by a shaft encoder or resolver. In some cases, the EMI(Electro Magnetic Interference), vibration, thermal, and humidity environments may cause the difficulties in maintaining the satisfactory performance for the position detection. Therefore, the elimination of the position and speed sensor is needed. In this paper, a new method for the position estimation of the SRG is proposed. The estimation of the flux is calculated by using the measured voltage and current. The rotor position gets from the flux profile. The output voltage is also controlled constantly by PR control algorithm. These methods are verified by computer simulations md experiments using DSP. Experimental results certificate that the proposed method is able to control the SRG stable, and keep the output voltage constant in spite of changing of the load.

Faded Color Correction using Classification Map in LCybCrg Color Space (LCybCrg 색 공간에서 분류맵을 이용한 바랜 색 보정)

  • Kyung, Wang-Jun;Kim, Dae-Chul;Lee, Cheol-Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.1-7
    • /
    • 2012
  • Generally, correction methods for faded images use illuminant estimation algorithms, such as the gray world assumption and white patch Retinex methods, as the phenomenon of color fading is regarded as an illuminant effect. However, this induces inaccurate faded color correction, as images fade at different rates according to the ink property, temperature, humidity, and illuminant. Therefore, this paper presents a color correction method for faded images using classification in LCybCrg color space. The input faded image is first separated according to the chromaticity based on LCybCrg opponent color space. The faded color correction is then performed based on the gray world assumption in RGB color space. Thereafter, weights calculated from CybCrg values are applied to reduce contour artifacts. As a result, the proposed method provides better color correction for faded images than previous methods.

Sorption characteristics of Green Tea (녹차(綠茶)의 흡습특성(吸濕特性))

  • Lee, Joo-Baek;Jung, Shin-Kyo;Sohn, Tae-Hwa;Choi, Jong-Uck
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.50-54
    • /
    • 1986
  • The sorption characteristics of green tea were investigated at $20^{\circ}C$ with various relative humidities. Particle size showed little effect on the sorption behavior of green tea. At low relative humidities below 57%, the sorption equilibrium were easily attained, but a high relative humidities above 75%, the sorption equilibrium were not reached after 10 days. From the estimation of sorption rate at arbitrary humidities an empirical equation was obtained; $Ln{\frac{dw}{dt}}=nLn(t)+Lnc$ The monolayer moisture contents of green tea obtained by B.E.T. equation were found to be 7.87%(powder) and 7.01%(whole), respectively.

  • PDF