• Title/Summary/Keyword: 슬러지침전

Search Result 138, Processing Time 0.022 seconds

Application of Ultra Rapid Coagulation for Securing Water Resource II: Study of CSO Treatment and Sludge Reuse (수자원 확보를 위한 URC공법의 적용 II: CSO의 처리와 슬러지 재활용에 관한 연구)

  • Park, Se Jin;Yoon, Tai Il;Cho, Kyung Chul;Kim, Chang Gyun
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.39-49
    • /
    • 2000
  • Ultra Rapid Coagulation (URC) can dramatically remove pollutants loaded in wastewater by adding weighted coagulation additives (WCA) and recycling sludge into the coagulation basin to increase settling velocity and surface adsorption ability of floc. Also settling chamber together with lamella plates offers the high rate settling velocity, which can economically treat a considerable amount of pollutants like as combined sewage overflow (CSO) during the heavy rainfall and reduce the pollutants load into the receiving water for securing water source. It was estimated optimal configuration of settling chamber by using fluent model and the possibilities of reusing the sludge generated in this system.

  • PDF

Effect of Oyster Shell Addition on the Dissolved Air Flotation and Sedimentation of Bulking Sludge (팽화슬러지의 용존공기부상과 침전에 미치는 굴패각 첨가의 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.82-88
    • /
    • 2007
  • The objective of this study is to examine the effect of the waste oyster shell powder as the addition agent in bulking sludge thickening of paper manufacturing plant using DAF(Dissolved Air Flotation) and gravitational sedimentation. The effect of parameters such as dosage and size distribution of oyster shell were examined. The results showed that the optimum dosage of mixed oyster shell(size range : $\sim250{\mu}m$) was 0.8 g/L. The oyster shell addition of 5.0 g/L in sedimentation process was increased thickening concentration of 3.25 times. When 5.0 g/L of oyster shell was added in DAF process, water content of sludge was decreased from 95.5% to 82.7% in dewatering process using Buchner funnel test device. When size of oyster shell was divided four ranges($\sim53{\mu}m$, $53\sim106{\mu}m$, $106\sim150{\mu}m$, $150\sim250{\mu}m$), optimum size range for the flotation and dewatering was $53\sim106{\mu}m$.

Study on Sludge Concentration Change in Batch Column (Batch Column에서의 슬러지농도변화에 대한 연구)

  • Park, Suk Gyun;Kang, Seon-Hong;Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.443-450
    • /
    • 2006
  • For understanding sludge concentration profile as a function of time, sludge was sampled at each sampling port. When sludge concentration was 3g/L, the vertical sludge concentration distribution was similar to that of 2g/L of sludge concentration. During the early stage of sludge settling, sludge concentration increased remarkably as the sludge interface height in batch column became lower. The higher sludge concentration became, the worse sludge setteability became. Also, the type of sludge settling was influenced with sludge concentration gradient in batch column. In the same concentration, the greater sludge concentration gradient was, the faster sludge interface settled down. And the changing sludge concentrations in a batch settling or a continuous settling were simulated by using the equation of sludge interface height change model.

Fluoride Removal Using Ready-Mixed Concrete Sludge (레미콘 슬러지를 이용한 불소제거)

  • Kang, Min-Koo;Shin, Gwan-Woo;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.803-808
    • /
    • 2013
  • The purpose of this study was performed to investigate the optimum conditions of pH, concrete sludge, seed dosage, mixing intensity, operation time in treating fluoride-containing wastewater as $CaF_2$ using the ready-mixed concrete sludge. Considering fluoride removal, water content, that pH 6, concrete sludge dosage of 10 g/L, Seed dosage ($CaF_2$) of 2 g/L, mixing intensity of 100 rpm and operation time of 60 min were found to be optimum. Correspondingly, removal of fluoride and water content was about 85% and 64%, respectively. Increase in amount of seed dosage did not affect fluoride removal efficiency. but the result that the water content is decreased was shown up in occuring the solid-liquid separation well.

Investigation on the Hydrodynamic Behaviors of the Clarifier with an Interior Baffle in WWTP by using of Radiotracer $^{99m}Tc$ ($^{99m}Tc$ 추적자를 이용한 하수처리 시설 내 침전조의 정류벽 설치 유무에 따른 유체거동 변화측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • The hydrodynamic behaviors of the clarifier with an interior baffle in a wastewater treatment plant was investigated by using a radiotracer $^{99m}Tc$(30 40 mCi) to verify the results of CFD(computational fluid dynamics) modelling in the previous study. The clarifier model was manufactured with consideration to the hydraulic similarity(1/21) of a real plant($L{\times}W{\times}H:2.6{\times}0.4{\times}0.2m$). By installation of an interior baffle to the clarifier, the strong density current at the bottom of the clarifier decreased substantially and increased the area of sludge settling zone, which were visualized successfully from the radiotracer experiment. Also the portion of short circuit stream changed from 48 % to 32 % and the mean residence time of sludge decreased from 940 sec to 810 sec, which corresponds to the results of CFD modelling. As a result, it is anticipated that radiotracer technology can be used as an important tool for designing new wastewater treatment plants and verifying their performances after structural modifications.

Application of activated carbon induced ballasted flocculation for improving activated sludge settleability (활성슬러지 침전성 향상을 위한 활성탄 가중응집제 적용 연구)

  • Kim, Yongbum;Yang, Hyeji;Choi, Younggun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.153-162
    • /
    • 2021
  • The effects of activated carbon originated Ballasted Flocculant (BF) on the settleability of activated sludge and the recovery of BF by Hydro-cyclone (HC) were analyzed experimentally. Two kinds of BF (M-I: 125-250 ㎛, M-II: 250-425 ㎛ in dia.) and three kinds of activated sludges with different SS concentration (2,300-7,100 mg/L) were applied for this study. With the dosage variation of BF from 0.14 to 1.3 g-BF/g-SS, we could obtain 24-31% improvement in SV30 (Sludge Volume after 30min sedimentation) for the lowest SS concentration sludge (2,300 mg/L). Whereas the SV30 improvement was much higher as 44-48% for the highest SS concentration sludge (7,100 mg/L). The settling characteristics of the sludge with BF followed Vesilind model the best among three models (Vesilind, Takacs and Cho model). HC could effectively separate BF with the separation efficiency of 70-90% and over 95% separation efficiency could be obtained when the HC was applied twice.

Prediction of Sludge-Water Interface Height Change in Batch Column (Batch Column에서의 슬러지계면층 높이변화 예측)

  • Park, Suk Gyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.156-163
    • /
    • 2006
  • While sludge is settling in batch column, sludge concentration becomes high. Because the characteristic of sludge settling changes in function of time due to the sludge concentration change, the sludge settling velocity changes too. Also, because the sludge settling characteristic is influenced by a physical characteristic of sludge and a column height etc, it is difficult to exactly measure the sludge settling characteristic. Although the sludge volume indexes, SVI, SSVI and $SSVI_{3.5}$, are used to predict sludge settling characteristic, these indexes are not reliable values. Because the previously established models for sludge settling velocity predict the sludge settling velocity only, it is difficult to predict sluge-water interface height by using those models. The purpose of this experiment is to establish the empirical model which predicts the sludge interface height change with respect to the sludge physical characteristic and the settling condition.

Alternative Method for the Treatment of Chemical Wastes Containing Uranium (우라늄함유 화학폐수의 적정처리 기술)

  • Kim Kil-Jeong;Shon Jong-Sik;Hong Kwon-Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.179-186
    • /
    • 2006
  • Chemical wastes are generated from nuclear facilities and R&D laboratories, but the uranium concentration in the final dried cake is evaluated into 11.2 Bq/g, which exceeds the exemption level of 10 Bq/g for each U isotopes, so the cake is categorized into a radioactive waste. Acid dissolution was applied to extract uranium from the waste sludge, and uranium adsorption on the dissolved solution was experimented by using IRN-77 and Diphosil bead. A large amount of resin was required to get above 80% of uranium removal, which was found to be due to a large amount of metal ions simultaneously dissolved from the precipitates with uranium. As an alternative method, acid dissolution is applied to the dewatered wet cake of the sludge, and the natural evaporation method is adopted for the dissolved solution. The uranium concentration of the dissolved solution was estimated to be 6.97E-01 Bq/ml, and the specific activity of the final waste sheets is evaluated to be 4.3 Bq/g. These results lead to the suggestion that the application of acid dissolution to the wet cake and the natural evaporation for the dissolved solution is an effective treatment method for chemical wastes containing uranium.

  • PDF

A Study on High Strength Nitrogen Wastewater Treatment and Sludge Granulation Characteristics in a Pilot-scale Air-lift Sequencing Batch Reactor (파일럿 규모의 공기 유동 연속회분반응기에서 고농도 질소제거 및 슬러지 그래뉼화 특성 연구)

  • Lee, Soochul;Kim, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.398-403
    • /
    • 2012
  • Selective nitrification and granulation have been carried out in a pilot scale air-lift sequencing batch reactor (SBR) for stable and economical nitrogen removal from wastewater. The SBR showed about 100% nitrification efficiency up to 1.0 kg ${NH_4}^+-N/m^3{\cdot}d$, about 90% efficiency at 1.0-2.0 kg ${NH_4}^+-N/m^3{\cdot}d$, and it was less than 90% when the load was higher than 2.0 kg ${NH_4}^+-N/m^3{\cdot}d$. Nitrite accumulation was induced by selective inhibition of nitrite oxidizing bacteria by free ammonia inhibition and dissolved oxygen limitation. For the purpose, high nitrite ratio (> 0.95) was obtained by keeping the pH higher than 8.0 and dissolved oxygen lower than 1.5 mg/L. In addition, sludge granulation was achieved by keeping reactor settling time to 5 minutes to wash out poor settling sludge and to promote the growth of granulation sludge. The operation accelerated sludge granulation and the sludge volume index (SVI) decreased and stably maintained to less than 75 in 60 days.