• Title/Summary/Keyword: 슬래그 엔지니어링

Search Result 12, Processing Time 0.021 seconds

Development of Iron and Steelmaking Processes by Slag Engineering Technology (슬래그 엔지니어링에 의한 製銃 및 제강조업의 효율향상에 관한 연구)

  • 박주현;민동준;송효석
    • Resources Recycling
    • /
    • v.10 no.3
    • /
    • pp.37-42
    • /
    • 2001
  • Current iron and steelmaking operation was re-evaluated on the basis of slag engineering technology to optimize slag operations. In blast furnace process, increase in the basicity of slags (C/S) could obtain progressed fluidity and hot metal quality. COREX process would be stabilized in view of slag fluidity and hot metal quality by reducing input content of $SiO_2$and $A1_2$$O_3$In STS-AOD process, addition of small amount of lime could improve refining capacity of the slag; also calcium aluminate flux could be taken into account as a potential substitute for fluorspar, without degradation of operation efficiency and steel quality.

  • PDF

Estimation of Gasification Performance and Slag System Capacity for 300MW IGCC Plant (300MW IGCC 가스화플랜트의 가스화 성능 및 Slag System 용량 예측)

  • Koo, Ja-Hyung;Paek, Min-Su;Yoo, Jeong-Seok;Kim, Bong-Keun;Kim, You-Seok;Lee, Hwang-Jik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.234-237
    • /
    • 2008
  • 분류층 가스화기에서 가스화기 운전 온도는 슬래그의 원활한 배출과 가스화기 성능 등에 영향을 미친다. 가스화기 운전온도는 또한, 석탄 및 산소 소비량에도 영향을 미쳐 궁극적으로는 가스화 플랜트의 주요 설비 용량을 결정하는 주요 요인중의 하나이다. 가스화기 운전 온도가 일정수준 이상으로 증가할 경우 냉가스 효율이 저하되고 가스화 성능에 약 영향을 미친다. 본 논문에서는 Coal 및 Flux 공급장치, 슬래그 배출장치 당의 구성을 설명하고 Flux 투입량에 따른 슬래그 Tcv, 가스화기 성능 등을 예측하였다. 또한, 300MW IGCC 실증 가스화플랜트 엔지니어링을 위한 예비단계로 석회석 투입에 따른 Flux 공급장치를 포함한 Feeding 설비 용량, 슬래그처리설비 용량, 가스화기 내부 및 출구 적정온도를 예측하였다.

  • PDF

Strength Properties of High-Strength Concrete Piles Using an Industrial by-Product (산업부산물을 치환한 고강도 콘크리트 말뚝의 강도 특성)

  • Shin, Kyoung-Su;Lim, Byung-Hoon;Hwang, Sun-Kyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.85-91
    • /
    • 2020
  • The necessity for ground reinforcement of structures has been increasing in South Korea because buildings have encountered constructional problems such as inclined structures and collapses caused by earthquakes or differential settlement of the foundations. With regard to a ground reinforcement method, an increasing number of high-strength concrete piles have been used based on their advantages, including a wide range of penetration depth and a high load-bearing capacity. However, problems such as the destruction of a pile head during on-site placement work can occur when the pile has insufficient strength. For this reason, the strength of such piles should be managed more thoroughly. Thus, this study analyzed the strength properties of high-strength concrete piles using blast furnace slag (BFS) powder as a cement replacement, which was generated as an industrial byproduct. The analysis results indicated that the compression strength of the concrete piles increased when 10% to 20% of the cement was replaced with ground granulated blast-furnace slag (GGBS). In addition, the compression strength of the concrete piles was calculated to be 80.6 MPa when 20% of the cement was replaced with GGBS, which was greater by 5% than that of an ordinary Portland cement (OPC) specimen.

Evaluation of Strength and Durability of Mortar using Ferronickel Slag Powder and Admixtures (페로니켈슬래그 미분말 및 혼화재의 복합사용에 따른 모르타르의 강도 및 내구성 평가)

  • Jo, Seol-Ah;Yoo, Jeong-Hwan;Park, Sang-Soon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.262-270
    • /
    • 2019
  • Ferronickel slag, which is an industrial byproduct, is activated by mechanochemical reaction as a nonferrous metal and can be used as an admixture. Therefore, ferronickel slag is used as a substitute resource of admixture. In this study, to evaluate the effect of mixed of ferronickel slag powder and admixture, a mortar using a mixture of ferronickel slag powder, quicklime, gypsum and calcium chloride was fabricated by vibrated and rolled manufacturing method. Strength were evaluated by flexural and compressive strength tests, and durability was evaluated by performing chlorine ion penetration resistance and chemical resistance test. When the substitution ratio of ferronickel slag powder is constant, it is considered that the mixed use of quicklime, gypsum and calcium chloride as admixtures increases the performance.

Development of the Decelerator for Briquetting Machine with Low Vibration (저진동 슬래그 분쇄장치용 감속기 개발)

  • Lee, Hyoung Woo;Hur, Nam Soo;Kim, In Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1043-1049
    • /
    • 2012
  • In order to develop the decelerator for briquetting machine which composed of multi-staged gears, shafts and bearings, static design of the decelerator has been carried out through the analysis of bending and face forces, including structural analysis, applied on those teeth in accordance with AGMA(American Gear Manufacturers Association) standard. And also, dynamic design has been carried out with considering of vibratory forces caused by unbalance mass and transmitting error of gear. On the results of vibration analysis, it has been confirmed that there is not any critical speed within its operating range.

Reduction of Hydration heat of FA concrete using Coal Gasification Slag for Mixed Fine Aggregate (석탄 가스화 용융 슬래그를 혼합 잔골재로 사용한 FA 치환 콘크리트의 수화열 저감)

  • Han, Jun-Hui;Lee, Young-Jun;Choi, Il-Kyung;Kim, Jung;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.79-80
    • /
    • 2019
  • This study was intended to examine the possibility of reducing hydration heat by FA substitution and combination of slag (CGS) from coal gasification power generation (IGCC) with mixed aggregate for concrete. The analysis results showed good results if liquidity increases as the ratio of CGS increases, air volume decreases, and compressive strength is mixed up to 25% in the residual aggregate. The results showed that the heat of hydration was reduced compared to plain due to the boron content of CGS as the CGS substitution rate increased, but it was larger due to the combination with FA substitution. It was found that the heat of hydration was reduced.

  • PDF

The Experimental Study of Flux Improvement of Wet Underwater Arc Welding Electrode (습식 수중 아크용접봉의 국산화개발에 관한 기초연구)

  • 김민남;김복인;노창석
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.180-186
    • /
    • 2001
  • Underwater wet welding process was experimentally investigated by using the six types of flux coated electrodes of 3.2mm diameter and the KR-RA steel plate of 11mm thickness as base metal. Two types of electrodes were domestic covered are welding electrode(CR13, CR14) and another two types of wet welding electrodes(UW-CS-01, TN-20) and the other two types(UW-X1, UW-X2) where individually designed flux coasted electrode for experimental welding purpose.

  • PDF

A Study on Validation of the Shielding Effectiveness Measurement Method of the Concrete Containing Electric Arc Furnace Oxidizing Slag (전기로산화슬래그를 활용한 콘크리트의 차폐효과 측정 방법의 유효성 검증 연구)

  • Jang, Hong-Je;Lee, Han-Hee;Choi, Hyo-Sik;Song, Tae-Seung;Cho, Won-Seo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.478-482
    • /
    • 2021
  • In this paper, methods for manufacturing shielding concrete by recycling steelmaking slag discarded as industrial waste and measuring the shielding effectiveness of the shielding concrete were studied. By comparing the result of shielding effectiveness measurement of this concrete block with shielding effectiveness measurement of the structure constructed with this concrete, the measurement system for measuring shielding effectiveness of the concrete block was verified. The size of the concrete stru ctu re is 2.9 × 2.9 × 3.4m and the concrete block is 0.3 × 0.3 × 0.2m. The frequ ency band u sed for mesu rement is 600MHz - 2GHz, the types of concrete u sed to measu re the shielding effectiveness are general concrete and concrete containing electric arc furnace oxidizing slag. In the case of the concrete structure, reinforcing rebars are installed at intervals of 15cm for stru ctu ral safety, as the frequ ency increase, the electromagnetic wave properties of rebars gradu ally decreased, there was a slight difference in the measurement results. In conclusion, the measurement result of shielding effectiveness of the concrete block is similar to the result of the concrete structure. It is thought that it can be sufficiently utilized for electromagnetic wave engineering design, and the concrete shielding effectiveness measurement system using standard specimens was verified.