• Title/Summary/Keyword: 슬괵건 횡고정 핀

Search Result 4, Processing Time 0.011 seconds

Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note- (슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기-)

  • In Yong;Bahk Won-Jong;Park Jong-Beom;Hong Seung-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Purpose : The purpose of this study was to introduce new femoral fixation technique using a cross-pin and a bioabsorbable interference screw in hamstring ACL reconstruction. Method : Semitendinosus and gracilis were harvested for quadrapled graft. After tibial tunnel had been made, femoral tunnel was made 35 mm in depth. Then the graft passed through the tunnels. Cross-pin was fixed through the drill hole which had been made through upper sleeve of the Rigidfix system. While pulling the graft, bioabsorbable interference screw was fixed through the anteromedial portal. Conclusion : We introduced the new femoral fixation technique using a cross-pin and a bioabsorbable interference screw as a good method with high fixation strength and tight graft-bone contact.

  • PDF

Comparison of Anterior Cruciate Ligament Reconstruction using Autogenous Patellar Tendon versus Quadruple Hamstring Tendon (자가 슬개건과 네 겹 슬괵건을 이용한 전방 십자 인대 재건술의 비교)

  • Kim, Seok-Jung;Kwon, Oh-Soo;Choi, Dong-Won;Song, Ho-Wook;Kang, Hyun-Taek;In, Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 2004
  • Purpose: To compare the results of two different autografts used to reconstruct the anterior cruciate ligament(ACL): bone-patellar tendon-bone and quadruple hamstring tendon. Materials and Methods: Forty one cases (20 bone-patellar tendon-bone cases and 21 quadruple hamstring tendon cases) were followed up more than 2 years postoperatively. Patellar tendons were fixed with interference screws and hamstring tendons were fixed with cross pins and intrafix sheaths and screws. Follow-up results were evaluated with KT-2000 arthrometer, International knee Documentation Committee(IKDC) evaluation form and follow up X-ray Donor site morbidity was analysed. Results: Final IKDC) scores more than B grade and side to side differences of manual maximum test using KT-2000 arthrometer showed insignificant differences(p>) between the two groups. Plain radiographs of hamstring group showed marked widening of the femoral and tibial tunnels at postoperative 2 years. Patellar tendon group showed 30% rate of anterior knee complications. Conclusion: ACL reconstruction using autogenous hamstring graft with new fixation method showed comparable clinical results to using autogenous patellar tendon graft with fewer anterior knee symptoms.

  • PDF

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF

Posterior Cruciate Ligament and Posterolateral Structure Reconstruction using Bilateral Hamstring Tendons (양측 슬괵건을 이용한 후방 십자 인대 및 후외측 지대 재건술)

  • In, Yong;Kim, Seok-Jung;Lee, Gyu-Yeong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate the clinical results of posterior cruciate ligament (PCL) and posterolateral structure (PLS) reconstruction using bilateral hamstring tendon autografts. Materials and Methods: From October 2002 to March 2004, ten patients were received PCL and PLS reconstruction simultaneously using bilateral hamstring autografts. PCL was reconstructed using ipsilateral hamstring tendon and fixed with cross pins and Intrafix (Mitek, Norwood, MA). PLS was reconstructed using contralateral hamstring tendon. The mean follow up was 17 months. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee (IKDC) evaluation form and posterior stress radiographs. External rotation of tibia was evaluated at $30^{\circ}\;and\;90^{\circ}$ knee flexion using Noyes and Barber-Westin's classification. Contralateral harvest site morbity was evaluated using IKDC evaluation form and flexion power of the knee. Results: Mean posterior displacement of tibia using stress radiographs was improved from 13.3 mm to 3.7 mm. In tibial external rotation evaluation, 7 patients were functional, 2 patients were partially functional and one failure. The average Lysholm knee score improved from 54 preoperatively to 86 postoperatively. At the final IKDC evaluation, 8 patients were graded as nearly normal, 2 were graded as abnormal. In contralateral harvest site morbidity evaluation, 2 patients complained of numbness around the wound but negligible. Conclusion: PCL and PLS reconstruction using bilateral hamstring autografts was considered as a good treatment method with minimal contralateral harvest site morbidity.

  • PDF