• Title/Summary/Keyword: 슬관절 각도

Search Result 109, Processing Time 0.021 seconds

Effects of Neuromuscular Electrical Stimulation of the Vastus Medialis on Pain and Muscle Function in Patients with Knee Osteoarthritis (내측광근의 신경근전기자극(NMES)이 퇴행성 슬관절염 환자의 통증 및 근 기능에 미치는 영향)

  • Jin, Yu-Shin;Jeong, Tae-Gyeong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.1
    • /
    • pp.329-337
    • /
    • 2012
  • The purpose of this study was to investigate the functional changes of the vastus medialis while the neuromuscular electrical stimulation(NMES) was performed in elderly women with knee osteoarthritis. The subjects of this study were 30 women who were diagnosed degenerative arthritis, 15 in the experimental group and 15 in the control group. The experimental group performed conventional physical therapy and neuromuscular electrical stimulation, and the control group received only conventional physical therapy, five times per week for four weeks. Outcome measures were assessed before and after 4weeks using the VAS(pain), quadriceps femoris strength, thigh circumference, and Q-angle. The data of the quadriceps femoris strength and thigh circumference were significantly increased in experimental group(p<0.05). The data the pain was significantly decreased in both the two groups(p<0.05). There were statistically significant differences in quadriceps femoris strength and thigh circumference between the two groups(p<0.05). As the result, the application of neuromuscular electrical stimulation of the vastus medialis could be more effective for decrease pain and improving muscle function in patients with knee osteoarthritis.

Effect of Task-Oriented Exercise on the Balance in Degenerative Arthritis Patients with Total Knee Replacement (과제 지향 훈련이 슬관절 전치환술을 시행한 퇴행성 관절염 환자의 균형 능력에 미치는 효과)

  • Ji, Sang-Goo;Kim, Myung-Kwon;Lee, Dong-Geol;Cha, Hyun-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.222-232
    • /
    • 2012
  • This study was conducted to compare the task-oriented exercise and weight-shifting exercise program has effectiveness on the static and dynamic balance in patients with total knee replacement. The participants were allocated randomly into 2 group : task-oriented exercise group(n=12) and weight-shifting exercise group(n=12). To evaluate the effects of exercise, subjects were evaluated by using Gaitveiw System and functional reaching test for static balance and Balance System for dynamic balance test. The data was analyzed using a paired t-test and independent t-test to determine the statistical significance. Static balance test and dynamic balance test in task-oriented exercise had statistical significance than weight-shifting exercise program(p<0.05). So this results were suggested that the task-oriented exercise was effective on static and dynamic balance in patients with total knee replacement.

Clinical Results of Medial Unicompartmental Knee Arthroplasty in Elderly Patients Older than 70 Years of Age (70세 이상의 고령 환자에서 시행한 내측 슬관절 단일구획치환술의 임상 결과)

  • Kim, Kyung Tae;Lee, Song;Kim, Jin Hak;Lee, Ho Young;Kim, Myung Jin
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • Purpose: To evaluate the long-term clinical results and survivorship of unicompartmental knee arthroplasty (UKA) in elderly patients older than 70 years by analyzing cases that have been implanted for >10 years ago. Materials and Methods: The long-term follow-up results were evaluated in 39 patients (46 cases) who underwent medial UKA from March 2002 to February 2004. The mean age of the patients at the time of surgery was 74.0 years, and the preoperative diagnosis was degenerative arthritis of the knee in all cases. Results: Of the 46 cases, reoperation occurred due to the complications in four cases. In 22 cases without 14 cases of death and six cases of follow-up loss, follow-up more than 10 years was possible. The mean Knee Society knee and function scores improved significantly from 53.0 and 52.5 points pre-operatively to 89.4 and 80.9 points at the last follow-up, respectively (p<0.001). The mean range of motion of the knee recovered to 132.5°, and the mean tibiofemoral angle changed to 5.9° of valgus at the last follow-up. Complications following the UKA occurred in four cases; the most prevalent complication was mobile bearing dislocation (n=2). One case of failure occurred due to aseptic loosening and degenerative arthritis of the lateral compartment, respectively. The cumulative survival rate of the implants was 95.0% at 10 years and 85.7% at 15 years. Of the 40 cases, excluding six cases of follow-up loss, 36 cases (90.0%) could be used without reoperation until death or at the last follow-up after surgery. Conclusion: These results showed the outstanding functions of the knee and satisfactory long-term survivorship after UKA. Therefore, UKA could be a useful method for the treatment of osteoarthritis of the knee in elderly patients older than 70 years of age.

Development of Leg Stiffness Controllable Artificial Tendon Actuator (LeSATA®) Part I - Gait Analysis of the Metatarsophalangeal Joint Tilt Angles Soonhyuck - (하지강성 가변 인공건 액추에이터(LeSATA®)의 개발 Part I - Metatarsophalangeal Joint Tilt Angle의 보행분석 -)

  • Han, Gi-Bong;Eo, Eun-Kyung;Oh, Seung-Hyun;Lee, Soon-Hyuck;Kim, Cheol-Woong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.153-165
    • /
    • 2013
  • The established gait analysis studies have regarded leg as one single spring. If we can design a knee-ankle actuating mechanism as a primary actuator for supporting knee extension, it might be possible to revolutionary store or release elastic strain energy, which is consumed during the gait cycle, and as a result leg stiffness is expected to increase. An ankle joint actuating mechanism that stores and releases the energy in ankle joint is expected to support and solve excessive artificial leg stiffness caused by the knee actuator (primary actuator) to a reasonable extent. If unnecessary kinematic energy is released with the artificial speed reduction control designed to prevent increase in gait speed caused by increase in time passed, it naturally brings question to the effectiveness of the actuator. As opposed to the already established studies, the authors are currently developing knee-ankle two actuator system under the concept of increasing lower limb stiffness by controlling the speed of gait in relative angular velocity of the two segments. Therefore, the author is convinced that compensatory mechanism caused by knee actuating must exist only in ankle joint. Ankle joint compensatory mechanism can be solved by reverse-examining the change in metatarso-phalangeal joint (MTPJ) tilt angle (${\theta}_1=0^{\circ}$, ${\theta}_2=17^{\circ}$, ${\theta}_3=30^{\circ}$) and the effect of change in gait speed on knee activity.

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF

Effects of a Thera-Band Exercise Program on Pain, Knee Flexion ROM, and Psychological Parameters Following Total Knee Arthroplasty (슬관절 전치환술 후 세라밴드 운동프로그램이 수술 후 통증, 슬관절 굴곡각도 및 심리적 지수에 미치는 효과)

  • Yun, Ji Yeong;Lee, Jong Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.6
    • /
    • pp.823-833
    • /
    • 2015
  • Purpose: The purpose of the study was to investigate the effects of the Thera-Band exercise program following total knee arthroplasty. Methods: The research design for this study was a nonequivalent control group non-synchronized design. Participants were 30 patients for the experimental group and 30 patients for the control group. The experimental group participated in the Thera-Band exercise program in addition to conventional CPM (continuous passive motion) exercise. The control group received conventional CPM exercise only. Outcome measures were pain, knee flexion range of motion, CRP, and psychological parameters (self-efficacy and fear of falling). Data were analyzed using ${\chi}^2$-test, Fisher's exact test, t-test, and repeated measure ANOVA with SPSS/PC version 21.0. Results: There were significant improvement in self-efficacy, and decreases in pain, and fear of falling in the experimental group compared to the control group. However, no significant differences were found between the two groups for CRP and knee flexion ROM. Conclusion: The Thera-Band exercise program gave an additional benefit over the conventional CPM exercise for patients following total knee arthroplasty, and is recommended for use as an effective nursing intervention for patients after total knee arthroplasty.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF

Effect of Knee Joint Stimulation on the Activity of Phrenic Nerve and Inspiratory Nuron in the Cat (슬관절 자극이 횡격신경 및 흡식중추신경에 미치는 영향)

  • Cho, Dong-Ill;Han, Hee-Chul;Nahm, Sook-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.683-693
    • /
    • 1993
  • Background: During movement the major inputs to nervous system come from firstly the muscle and joint to maintain posture and motion and secondly the chemoreceptors and baroreceptors to adjust the cardiovascular and respiratory function. Their complex relationships are generally studied for many years but the direct relation between the joint and respiratory system is not studied thoroughly until now. So this experiment was performed to determine whether the natural movement of knee joint can cause the enhancement of respiratory function by observation of the changes of respiratory rate, phrenic nerve activity and inspiratory neuron activity during the stimulation of knee joint in cat anesthetized with $\alpha$-chloralose. Method: Twenty six male adult cats were used and the extracelluar recording using bipolar platinum electrode and carbon filament electrode was done to record the changes in the activities of phrenic nerve and inspiratory neuron movement of knee joint, injection of chemicals into the joint cavity and electrical stimulation of articular nerve were done. Results: The 60 Hz. could not but 120 Hz. flexion-extension movement of knee joint increased respiratory rate(R.R.), tidal neural activity(TNA) and minute neural activity(MNA). Intra-articular injection of lactate could not increase R.R. but significantly increase TNA and MNA which represented the enhanced respiratory function. Injection of potassium chloride showed similar effects with the case of lactate but the duration of effect was shorter. The electrical stimulation of medial articular nerve with IV strength which could activate only group I and II afferents showed increased TNA and MNA during stimulation but 20 V stimulation which could activate all the afferents increased all the respiratory parameters. The changes of inspiratory neuron activity by knee joint stimulation was similar to that of phrenic nerve. Conclusion: The respiratory center could be directly stimulated by the activation of group I and II articular afferents and it seemed that the magnitude of the respiratory center enhancement is proportional to the amount of sensory information from the knee joint. These facts might suggest that the respiratory function could be enhanced even by the normal movement of knee joint.

  • PDF

Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint (슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가)

  • Yoon, Moon-Hyun;Seung, Mi-Sook;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2008
  • Although MR imaging is generally applicable to depict knee joint deterioration it, is sometimes occurred to mis-read and mis-diagnose the common knee joint diseases. In this study, we employed magnetization transfer ratio (MTR) method to improve the diagnosis of the various knee joint diseases. Spin-echo (SE) T2-weighted images (TR/TE 3,400-3,500/90-100 ms) were obtained in seven cases of knee joint deterioration, FSE T2-weighted images (TR/TE 4,500-5,000/100-108 ms) were obtained in seven cases of knee joint deterioration, gradient-echo (GRE) T2-weighted images (TR/TE 9/4.56/$50^{\circ}$ flip angle, NEX 1) were obtained in 3 cases of knee joint deterioration, In six cases of knee joint deterioration, fat suppression was performed using a T2-weighted short T1/tau inverse recovery (STIR) sequence (TR/TE =2,894-3,215 ms/70 ms, NEX 3, ETL 9). Calculation of MTR for individual pixels was performed on registration of unsaturated and saturated images. After processing to make MTR images, the images were displayed in gray color. For improving diagnosis, three-dimensional isotropic volume images, the MR tristimulus color mapping and the MTR map was employed. MTR images showed diagnostic images quality to assess the patients' pathologies. The intensity difference between MTR images and conventional MRI was seen on the color bar. The profile graph on MTR imaging effect showed a quantitative measure of the relative decrease in signal intensity due to the MT pulse. To diagnose the pathologies of the knee joint, the profile graph data was shown on the image as a small cross. The present study indicated that MTR images in the knee joint were feasible. Investigation of physical change on MTR imaging enables to provide us more insight in the physical and technical basis of MTR imaging. MTR images could be useful for rapid assessment of diseases that we examine unambiguous contrast in MT images of knee disorder patients.

  • PDF

A Gait Analysis Using Smart Phone Images of the Knee Joint Angle and Stride Length (스마트폰 영상을 이용한 슬관절 각도 및 활보장에 대한 보행분석)

  • Jang, J.H.;Lim, C.J.;Song, K.H.;Chung, S.T.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.139-144
    • /
    • 2013
  • Various types of disease in the nervous and musculoskeletal system can change gait, and the gait analysis is very important in determining the progression of the disease. Most methods of analyzing gait are subject to high-priced equipment and spatial restrictions. This study used smart phone images and the walking track analysis program to make a comparative analysis with the existing gait analysis on the basis of the stride length measurements and the changes in the knee joint angle for walking. The test necessary to analyze gait was conducted in seven healthy men, and data about the angle of right and left knee joints and stride length were used to analyze gait. The gait analysis in this study obtained the similar results to the existing ones. The use of the methods suggested in this study will enable gait analysis to be made without high-priced equipment and spatial restrictions.

  • PDF