• Title/Summary/Keyword: 스프링클러관련 법

Search Result 3, Processing Time 0.018 seconds

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

Mechanism and Spray Characteristics of a Mini-Sprinkler with Downward Spray for Prevention of Drop Water (하향 분사식 미니스프링클러의 낙수방지 메카니즘과 살수 특성)

  • Kim, Hong-Gyoo;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • A study was conducted to find mechanism and spray characteristics of a mini-sprinkler with downward spray to develop a new design type to be able to prevent drop water. The experiments were executed in a plastic greenhouse to minimize the effect of the wind. Data was collected at five different operation pressures and at 4 different raiser heights. Spray characteristics of the sprinkler such as effective radius, effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. In order to analyze the mechanism and packing supporter of sprinkler, the numerical simulation using ABAQUS was performed. The optimum pressure for preventing drop water was determined.

Project of Improving Good Agriculture Practice and Income by Intergrated Agricultural Farming (미얀마 우수농산물 재배기술 전수사업)

  • Lee, Young-Cheul;Choi, Dong-Yong
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.16 no.1
    • /
    • pp.193-206
    • /
    • 2014
  • The objectives of the project are to increase farmers' income through GAP and to reduce the loss of agricultural produce, for which the Korean partner takes a role of transferring needed technologies to the project site. To accomplish the project plan, it is set to implement the project with six components: construction of buildings, installation of agricultural facilities, establishment of demonstration farms, dispatching experts, conducting training program in Korea and provision of equipments. The Project Management Committee and the Project Implementation Team are consisted of Korean experts and senior officials from Department of Agriculture, Myanmar that managed the project systematically to ensure the success of the project. The process of the project are; the ceremony of laying the foundation and commencing the construction of training center in April, 2012. The Ribbon Cutting Ceremony for the completion of GAP Training Center was successfully held under PMC (MOAI, GAPI/ARDC) arrangement in SAl, Naypyitaw on June 17, 2012. The Chairman of GAPI, Dr. Sang Mu Lee, Director General U Kyaw Win of DOA, officials and staff members from Korea and Myanmar, teachers and students from SAl attended the ceremony. The team carried out an inspection and fixing donors' plates on donated project machineries, agro-equipments, vehicles, computers and printer, furniture, tools and so forth. Demonstration farm for paddy rice, fruits and vegetables was laid out in April, 2012. Twenty nine Korean rice varieties and many Korean vegetable varieties were introduced into GAP Project farm to check the suitability of the varieties under Myanmar growing conditions. Paddy was cultivated three times in DAR and twice in SAl. In June 2012, vinyl houses were started to be constructed for raising seedlings and finished in December 2012. Fruit orchard for mango, longan and dragon fruit was established in June, 2012. Vegetables were grown until successful harvest and the harvested produce was used for panel testing and distribution in January 2013. Machineries for postharvest handling systems were imported in November 2012. Setting the washing line for vegetables were finished and the system as run for testing in June 2013. New water tanks, pine lines, pump house and electricity were set up in October 2013.