• Title/Summary/Keyword: 스티로폼 지지대

Search Result 2, Processing Time 0.017 seconds

Design of an Ultra-Wideband LPDA Antenna for the Feeder of an Airborne Spinning Direction-Finding Reflector Antenna (공중 회전 방향탐지 반사판 안테나 급전기용 초광대역 LPDA 안테나 설계)

  • Park, Young-Ju;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.7
    • /
    • pp.653-659
    • /
    • 2016
  • This paper proposes an ultra-wideband Log-Periodic Dipole Array(LPDA) antenna for the feeder of a reflector antenna to be used for airborne spinning direction-finding and detecting wideband signals. To obtain the ultra-wideband characteristics over the 20:1 bandwidth from S to Ka band, the radiation elements of the antenna were printed on a substrate and a wedge-typed dielectric supporter with robust structure was inserted between the substrates. Also, the center portion of the supporter was replaced by a styrofoam material to reduce the supporter weight. The 5-dB return loss of the designed LPDA antenna showed ultra-wideband characteristics, which are 37.57:1(1.09~40.95 GHz) in the simulation and 33.85:1(1.31~44.35 GHz) in the measurement. We achieved the required gains of 5.78 dBi in the simulation and 5.76 dBi in the measurement in the operating band. The proposed robust, light-weight, and ultra-wideband LPDA antenna confirmed that it can be applied for airborne applications.

Image Analysis of Angle Changes in the Forearm during Elbow Joint Lateral General Radiography: Evaluation of Humerus Epicondyle and Elbow Joint (팔꿉관절 측방향 일반촬영에서 아래팔뼈 각도 변화에 따른 영상 분석 : 위팔뼈 위관절융기와 팔꿉관절 평가)

  • Hyo-Soo Shin;Hye-Won Jang;Jong-Bae Park;Ki Baek Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.607-614
    • /
    • 2023
  • Clear overlapping of the bilateral epicondyle and proper separation of the elbow joint are crucial for obtaining accurate lateral general radiographs of the elbow. However, due to the complex anatomical structure of the elbow, achieving optimal positioning is challenging, leading to the need for repeated x-ray examinations. Therefore, the purpose of this study was to investigate the angle of the forearm in patients where accurate lateral images of the elbow joint can't be obtained after vertical incidence using a styrofoam device during elbow joint lateral x-ray imaging. Twenty patients were enrolled in our study following the established protocol. First, a vertical x-ray at an angle of 0° between the forearm and the table was taken (control group). Here, if the lateral image of the elbow joint was deemed inadequate, the forearm angle was adjusted using custom-made styrofoam supports with 5° and 10° inclinations (experimental groups). For the evaluation method, two assessors utilized a 5-point Likert scale to assess the images. The reliability of the assessments was analyzed using Cronbach's alpha coefficient. As a result, patients with inadequate overlap of the bilateral epicondyle and separation of the elbow joint in the initial examination (control group) were able to obtain the best images when setting a 10° angle between the forearm and the table. The subjective evaluation was 1.6 ± 0.8 points at 0°, 2.7 ± 0.8 points at 5°, and 4.4 ± 1.3 points at 10°, respectively. The reliability analysis for the angles of 0°, 5°, and 10° yielded Cronbach's alpha values of 0.867, 0.697, and 0.922, respectively. In conclusion, when it is not possible to obtain accurate images using the conventional position and X-ray beam direction, it is considered that by initially acquiring images with an angle of 10° between the forearm and the table, and gradually decreasing the angle while obtaining images, it would be possible to achieve the optimal image while reducing the number of repeat examinations.