• Title/Summary/Keyword: 스템 마찰

Search Result 17, Processing Time 0.023 seconds

A Study on the contact surface of Stem and Bellows of Gate Valve in Nuclear Power Plants (원자력발전소 게이트밸브의 스템 - 벨로우즈 접촉면에 관한 연구)

  • Ko, Seok-Hoon;Shim, Dong-Hyouk;Kim, Dae-Youl;Choi, Myung-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1044-1048
    • /
    • 2006
  • Nuclear power generation is very dangerous in occasion that skirt of structure by earthquake although it is high effective generation that can make a lot of energies with few raw material. when design, it must consider a lot of problems caused by an earthquake. The seismic analysis of the structure has been great concern in the engineering society with an effort to reduce the severe damages from an earthquake. So the earthquake resistant design is one of the crucial design procedures of a gate valve used in nuclear power generation. The gate valve which has the contact area between stem and bellows. Because of the contact area. The gate valve should be given high stress and frictional wear. In this thesis, Considering the gate valve which has some contact distance between stem and bellows. The gate valve which has some contact distance is analyzed by a commercial FEM code of Ansys and Then compared to the gate valve behavior which doesn't have contact distance.

  • PDF

Stack Effect Mitigation Methods in Exit Route of High-rise Building (고층 건축물 피난경로의 연돌효과 저감 방안)

  • Kim, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.284-288
    • /
    • 2010
  • Length of staircase get longer and evacuation load get heavier in proportion to the building height. Therefore evacuation time could be considered proportional to square of building height. While smoke spreads vertically so rapidly, evacuation speed is too slow, therefore the reasonable measure for the safe of egress route is urgent. Existing pressurizing smoke control system of vertical exit route is seriously limited in function under the stack effect in winter. Stack effect in winter could be overcome with the methods of opening the staircase outward or letting airflow be free between staircase and outside.

  • PDF

A Study on the Bounding Value of Valve Performance Parameters for Motor Operated Flexible Wedge Gate Valve (모터구동 Flexible Wedge형 게이트밸브의 밸브 성능인자 Bounding Value에 대한 연구)

  • Kim, Dae-Woong;Yoo, Seong-Yeon;Park, Sung-Keun;Lee, Do-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.46-53
    • /
    • 2007
  • Stem friction coefficient and valve factor are very important parameters for the evaluation of valve performance. In this study, the characteristics of stem friction coefficient and valve factor are analyzed, and thor bounding value is determined. The hydraulic testing is performed for many flexible wedge gate valves in the plant and statistical method is applied to the determination of bounding value. According to the results of this study, stem friction coefficient does not change much with differential pressure, and the bounding value of closing stroke is higher than that of opening stroke. The valve factor of valves with high differential pressure is higher than that of valves with medium differential pressure. It means valve factor is more sensitive to the differential pressure than the stem friction coefficient. Valve factor of the closing stroke is higher than that of opening stroke due to piston effect.

Study on Fuzzy Control of Electric Car via TMS320F240 (TMS320F240 칩을 이용한 전동차의 퍼지 주행 제어기에 대한 연구)

  • Son, J.W.;Choi, S.M.;Song, D.K.;Kim, J.K.;Bae, J.I.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2381-2383
    • /
    • 1998
  • 직류직권모터는 전동지게차와 같은 물류용 전동차에서 사용되는데, 우수한 기동 토오크를 가지는 반면에 파라미터의 열적, 변화가 심하고 마찰과 부하의 비선형성이 존재해 기존의 제어기로는 만족할 만한 성능을 내지 못한다. 본 논문에서는 이를 해결하기 위해 퍼지제어기를 사용한다. 퍼지제어기는 변수의 애매성에 바탕을 두고 제어하기 때문에 이러한 비선형성에 대해 강인하나, 소속함수의 결정과 퍼지규칙의 선정이 어려우며, 체계적인 방법이 존재하지 않는다. 이러한 퍼지제 어의 결점을 해결하기 위해 소속함수는 유전 알고리즘을 통해 자기동조 시키며 퍼지규칙은 오차와 오차변화율의 위상평면을 이용하여 결정한다. 실용성을 검증하기 위해 TI사의 DSP TMS320F240을 이용해 실시스템에 적용했으며, 이를 통해 부하의 변동 및 기준 속도의 변화에도 잘 대처함을 알 수가 있었다.

  • PDF

Vessel Collision Analysis of an Underwater Soil Slope using Coupled Eulerian-Lagrangian Scheme 2: Parametric Study (Coupled Eulerian-Lagrangian 기법을 이용한 선박의 수중사면 충돌해석 2 : 매개변수연구)

  • Lee, Gyehee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • In this study, parametric analyses are performed using the coupled Eulerian-Lagrangian scheme for the collision behaviors of a vessel and an underwater slope that constitutes part of an artificial protective island. The vessel parameters considered in the analysis are bow angle, stem angle, draft, and impact velocity. The gradient of the slope, the friction coefficient between the bow and the slope, and soil strength are considered as parameters of the slope. For each parameter, the dissipated collision energy and the collision force are estimated from the behavior of the vessel, and the energy dissipation mechanism is identified in terms of the ground deformation. The collision force is assumed as an exponential function, and the effects of the parameters are estimated. As a result, only two parameters, the gradient of the slope and the friction coefficient between the vessel and the soil, can affect the exponential coefficient of the function. The dissipated energy by the soil can thus be estimated adequately. The relationship between the volume of the soil pushed out by the bow and the dissipated collision energy is estimated as a linear function. This relationship is independent of the magnitude of the collision energy, and affected more by the friction coefficient and the soil strength than by the parameters of the vessel.

The Analysis of Correlation Major System Factors with the Performance of Smoke Control Systems Using Pressure Differentials (차압제연설비의 성능과 관련된 시스템 및 환경 변수와의 상관성 분석)

  • Yeo, Yong-Ju;Kim, Hak-Jung;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • The smoke control systems using pressure differentials are already well known as the most reliable method to prevent the smoke infiltration into the emergency stairs or safe spaces. However, it is true that many problems are domestically pointed out due to the insufficient understanding and technology on the smoke control systems using pressure differentials. In this regard, this work analyzed the effect of major factors for smoke control system using pressure differentials such as a duct area, opening area of air supply damper, improvement on open vestibules, stack effect and location of air supply. In conclusion, adequate pressure differentials can not be maintained in small duct because the smaller duct area have the large friction loss. Especially, It is confirmed that the major factor for deterioration of smoke control system performance is stack effect that makes pressure differentials smaller in the lower floors.

Some Dynamical Issues about the Tsushima Warm Current based on Bibliographical Review (서지학적으로 본 대마난류의 몇 가지 역학적 쟁점들)

  • SEUNG, YOUNG HO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.3
    • /
    • pp.439-447
    • /
    • 2019
  • Some dynamical issues about the Tsushima Warm Current (TWC) are reviewed and checked for the remaining unresolved problems, focusing on the formation of the TWC, seasonal variation of its volume transport and its branching in the East Sea. The TWC is a part of the North Pacific (NP) subtropical gyre driven by the NP global wind system. However, the quantitative amount of volume transport is sensitive to friction, basin geometry, barrier effect and so on. Among many causes suggested by many scientists, subpolar winds are found to be most closely related with the seasonal variation of TWC volume transport. However, more studies relating the latter not only to the subpolar winds but also to those including the subtropical winds seem to be required. The branching of the TWC has been known to be due to the western intensification for the East Korean Warm Current (EKWC) and to the bottom trapping for the Nearshore Branch. Since the former hypothesis is problematic in explaining the seasonal variation of the EKWC, other candidate mechanisms may need to be considered.