• 제목/요약/키워드: 스테레오스코픽 PIV

검색결과 8건 처리시간 0.02초

미세제트 유동의 Stereoscopic micro-PIV측정 (Stereoscopic micro-PIV measurements of jet flow)

  • 유청환;김형범
    • 한국가시화정보학회지
    • /
    • 제5권1호
    • /
    • pp.43-48
    • /
    • 2007
  • Micro-PIV(particle image velocimetry) has been widely used to measure the velocity of micro flow. Although this micro-PIV method can give accurate 2D instantaneous velocity information of mea-surement plane, it cannot resolve the out of plane component of velocity vectors. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is useful to understand the physics of micro flow phenomena. In this study, we constructed stereoscopic micro-PIV(SMPIV) system and applied this method to the impinging micro jet flow. The results show that this method can produce accu-rate 3D reconstruction of micro jet flow.

CH-OH PLIF와 Stereoscopic PIV계측법을 이용한 난류예혼합화염의 관찰 (Simultaneous Measurement of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames)

  • 최경민
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.102-103
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry(PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Renolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Renolds number turbulent premixed flame.

  • PDF

삼각형 멀티 탭이 부착된 난류제트에 대한 SPIV 유동해석 연구 (SPIV Flow Analysis of Turbulent Jet with Triangular Multi-Tabs)

  • 장영길;이상준
    • 대한기계학회논문집B
    • /
    • 제29권5호
    • /
    • pp.561-567
    • /
    • 2005
  • The effect of triangular multi-tabs attached at the perimeter of jet nozzle on flow structure in the near field was investigated experimentally. A stereoscopic PIV(SPIV) system was employed to measure three orthogonal velocity components of the 3-D turbulent jet. In this study, two different types of sharp-edged jet nozzle having 4, 8 tabs were tested at the Reynolds number of Re=10,000. SPIV measurements were carried out at 5 cross-sectional planes. Six hundred instantaneous velocity fields were measured for each experimental condition and they were ensemble averaged to get spatial distributions of turbulent statistics such as mean velocity and turbulence intensity. Entrainment rate of surrounding fluid into the tabbed jets was estimated using the measured 3-D velocity field data. The strong vortex structure was induced for the jet flow with 4 tabs, increasing entrainment rate.

Stereoscopic PIV 기법을 이용한 선박용 프로펠러 후류의 3차원 속도장 측정 (Three Component Velocity Field Measurements of Turbulent Wake behind a Marine Propeller Using a Stereoscopic PIV Technique)

  • 이상준;백부근;윤정환
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1716-1723
    • /
    • 2003
  • A stereoscopic PIV(Particle Image Velocimetry) technique was employed to measure the 3 dimensional flow structure of turbulent wake behind a marine propeller with 5 blades. The out-of-plane velocity component was determined using two CCD cameras with the angular displacement configuration. Four hundred instantaneous velocity fields were measured for each of four different blade phases and ensemble averaged to investigate the spatial evolution of the propeller wake in the near-wake region from the trailing edge to one propeller diameter(D) downstream. The phase-averaged velocity fields show the potential wake and the viscous wake developed along the blade surfaces. Tip vortices were generated periodically and the slipstream contraction occurs in the near-wake region. The out-of-plane velocity component and strain rate have large values at the locations of tip and trailing vortices. As the flow goes downstream, the turbulence intensity, the strength of tip vortices and the magnitude of out-of-plane velocity component at trailing vortices are decreased due to viscous dissipation, turbulence diffusion and blade-to-blade interaction.

2D PIV와 stereoscopic PIV 기법으로 측정한 프로펠러 후류의 속도장 비교 연구 (Comparison of Velocity Fields of Wake behind a Propeller Using 2D PIV and stereoscopic PIV)

  • 백부근;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.23-26
    • /
    • 2002
  • The phase-averaged velocity fields of 3 dimensional turbulent wake behind a marine propeller measured by 2D PIV and stereoscopic PIV(SPIV) were compared directly. In-plane velocity fields obtained from the consecutive particle images captured by one camera in 2D PIV have perspective errors due to out-of-plane motion. However, the perspective errors can be removed by measuring three component velocity fields using SPIV method with two cameras. It is also necessary to measure three components velocity fields for the investigation of complicated near-wake behind the propeller for the suitable propeller design. 400 instantaneous velocity fields were measured for each of four different blade phases of $0^{\circ},\;18^{\circ},\;36^{\circ}C\;and\;54^{\circ}$. They were ensemble averaged to investigate the spatial evolution of the propeller wake in the downstream region. The phase-averaged velocity fields show the viscous wake developed along the blade surfaces and tip vortices were formed periodically. The perspective errors caused by the out-of-plane motion was estimated by the comparison of 2D PIV and SPIV results. The difference in the axial mean velocity fields measured by both techniques are nearly proportional to the mean out-of-plane velocity component which has large values in the regions of the tip and trailing vortices. The axial turbulence intensity measured by 2D PIV was overestimated since the out-of-plane velocity fluctuations influence the in-plane velocity vectors and increase the in-plane turbulence intensities.

  • PDF

Stereoscopic PIV기법을 이용한 프로펠러 후류의 3차원 속도장 측정 (3-D Velocity Fields Measurements of Propeller Wake Using a Stereoscopic PIV)

  • 백부근;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.185-188
    • /
    • 2002
  • The objective of present paper is to apply a stereoscopic PIV(Particle Image Velocimetry) techiique for measuring the 3 dimensional flow structure of turbulent wake behind a marine propeller with 5 blades. It is essential to measure 3-components velocity fields for the investigation of complicated near-wake behind the propeller. The out-of-plane velocity component was measured using the particle images captured by two CCD cameras in the angular displacement configuration.400 instantaneous velocity fields were measured for each of few different blade phases of $0^{\circ},\;18^{\circ},\;36^{\circ}\;and\;54^{\circ}$. They were ensemble averaged to investigate the spatial evolution of the propeller wake in the region ranged from the trailing edge to the region of one propeller diameter(D) downstream. The phase-averaged velocity fields show the viscous wake formed by the boundary layers developed along the blade surfaces. Tip vortices were formed periodically and the slipstream contraction occurs in the near-wake region. The out-of-plane velocity component has large values at the tip and trailing votices. With going downstream, the axial turbulence intensity and the strength of tip vortices were decreased due to the visous dissipation, turbulence diffusion and blade-to-blade interaction. The blade wake traveling at higher speed with respect to the tip vortex overtakes and interacts with tip vortices formed from the previous blade. Tip vortices are separated from the wake and show oscillating trajectory

  • PDF

예인수조용 스테레오스코픽 입자영상유속계 시스템의 불확실성 해석 (Uncertainty Assessment of a Towed Underwater Stereoscopic PIV System)

  • 서정화;설동명;한범우;유극상;임태구;박성택;이신형
    • 대한조선학회논문집
    • /
    • 제51권4호
    • /
    • pp.311-320
    • /
    • 2014
  • Test uncertainty of a towed underwater Stereoscopic Particle Image Velocimetry (SPIV) system was assessed in a towing tank. To estimate the systematic error and random error of mean velocity and turbulence properties measurement, velocity field of uniform flow was measured. Total uncertainty of the axial component of mean velocity was 1.45% of the uniform flow speed and total uncertainty of turbulence properties was 3.03%. Besides, variation of particle displacement was applied to identify the change of error distribution. In results for variation of particle displacement, the error rapidly increases with particle movement under one pixel. In addition, a nominal wake of a model ship was measured and compared with existing experimental data by five-hole Pitot tubes, Pitot-static tube, and hot wire anemometer. For mean velocity, small local vortex was identified with high spatial resolution of SPIV, but has serious disagreement in local maxima of turbulence properties due to limited sampling rate.