• Title/Summary/Keyword: 스터드간격비

Search Result 14, Processing Time 0.019 seconds

Analytical Study for Design of Shape and Arrangement Spacing of Studs in Steel Plate Concrete(SC) Wall subjected to Shear and Axial Forces (전단력과 축하중을 받는 강판 콘크리트(SC) 벽체에서 스터드의 형상과 배치간격의 설계를 위한 해석적 연구)

  • Cho, Sung-Gook;Lim, Jin-Sun;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.67-76
    • /
    • 2014
  • In this study, the behavior of Steel Plate Concrete (SC) walls subjected to shear and axial forces to investigate the effects of shape and arrangement spacing of studs on the design of SC walls was analytically reviewed. For this purpose, 9 cases of finite element analyses considering the different shape and spacing of studs in SC wall were performed. The results showed that the steel plate was yielded at the lower load than the second yielding shear force of the design skeleton curve when the spacing of stud is excessively far from each other. It is also found that the shape of the stud did not affect the shear behavior of SC wall but, the spacing influenced to its composite action. In this study, it was also proven that the inclined shaped stud resists more effectively to the bucking load than the general shaped stud in SC wall.

Analytical Study for Performance Evaluation of Studs for Steel Plate Concrete(SC) Walls subjected to Cyclic Loads (반복하중이 가해지는 강판 콘크리트(SC) 벽체에서 스터드의 성능평가를 위한 해석적 연구)

  • Lim, Jin-Sun;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.35-42
    • /
    • 2015
  • This study analytically reviewed the behavior of Steel Plate Concrete(SC) walls subjected to cyclic loads to investigate the effects of shape and arrangement spacing of studs on the behavior of SC walls. To perform it, 9 cases of finite element analyses considering the different shape and spacing of studs in SC wall were carried out. As the results, the skeleton curves were obtained from the load-displacement history curves and the ultimate and yielding forces were increased as the spacing of studs decrease. In addition, the strength of inclined studs are shown to be bigger compared to that of general studs. The damping ratios are increased as the decrease of strength ratio. Finally, as the decrease of stud spacings, the cumulative dissipated energy was increased and the seismic performance was improved.

Analytical Study for Performance Evaluation of Studs for Steel Plate Concrete (SC) Walls subjected to Forced Vibration (강제진동을 받는 강판 콘크리트 (SC) 벽체에서 스터드의 성능평가를 위한 해석적 연구)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.75-82
    • /
    • 2016
  • This study analytically reviewed the behavior of steel plate concrete (SC) walls subjected to forced vibration to investigate the effects of shape and arrangement spacing of studs on the behavior spacing of studs in SC wall were carried out. From the analyses, it was noted that the damping ratio obtained from the time history analyses showed overall high value in Half-power Bandwidth method and the lowest value in Fitted Exponential Curve method. And, in half of the design strength, the damping ratio presented approximately 3.0~4.2% and, in the design strength, it was approximately 4.1~5.2%. When the developed studs were used, the damping ratio was reduced slightly and it did not show consistent results between DS1 and DS2. When the distance between the studs increases more than necessary, it was also confirmed that the natural frequency was reduced and the damping ratio was increased.

Evaluation of Static Strength of Group Stud Shear Connection in Precast Concrete Deck Bridges (프리캐스트 콘크리트 바닥판 교량의 그룹 스터드 전단연결부 강도평가)

  • Shim, Chang Su;Jeon, Seung Min;Kim, Dong Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.333-345
    • /
    • 2008
  • concrete deck bridges are increasingly aplied to twin- girder bridges and open-stel box girder bridges.One of the most dificult isues in the design of shear conect ors is the mater of achieving ful composite action. Many connectors in smal area require a significant section los of precast decks resulting in difficult reinforcement details. In this closer spacing than the required minimum spacing in the design codes was evaluated through static tests. Test results s howed that the ultimate strength decreased as the conector spacing was reduced. The strength enhancement was observed due to aditional reinforcement for precast slabs or for shear pockets. Thus, the design of group stud shear connection needs to anticipate failure modes and the conector failure should be induced. Based on the test results, an empirical equation consi dering stud spacing was proposed to evaluate the ultimate strength of group stud shear conection. Fatigue tests showed n o reduction in fatigue life of the group stud shear conection in the range of this research. Details of the precast decks wer e enhanced using the findings of the study.

Compression Tests for Unstiffened Steel Plate-Concrete Structures with Variation of B/t Ratio (스터드 간격과 강판두께의 비를 변수로 한 비보강 강판-콘크리트 구조의 압축실험)

  • Choi, Byong Jeong;Han, Hong Soo;Kim, Won Ki;Lee, Seung Joon;Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.561-570
    • /
    • 2008
  • The primary object of the paper is to identify the compression forces and inelastic failure behavior using steel plate-concrete structures. The compression tests were carried out for the three types of B/tratios by 25, 33 and 50. The tests proved that the compressive strength of the SC structures can be estimated by the summation of strengths both of the steel plate and concrete. The buckling of the steel plates had been occurring at the plates between studs. The empirical estimation of compressive strength for unstiffened SC structures under compressive loadings was suggested. The buckling behavior was also compared with the results of the finite element analysis.

Compression Tests for Stiffened Steel Plate-Concrete Structures with Variation of B/t Ratio (스터드 간격과 강판두께의 비를 변수로 한 보강 강판-콘크리트 구조의 압축실험)

  • Choi, Byong Jeong;Han, Hong Soo;Kim, Won Ki;Lee, Seung Joon;Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.549-559
    • /
    • 2008
  • The objective of this paper is to identify the compression forces and inelastic failure mode using stiffened steel plate-concrete structures. The compression tests were carried out for the three types of B/t ratios by 25, 33 and 50. The test results proved that the compressive strength of the stiffened SC structures can be estimated by the summation of the strengths both stiffened steel plate and concrete. The buckling of the steel plates had been occurred at the plates between studs. The empirical estimation of compressive strength for the stiffened SC structures under compressive loadings was suggested. The buckling behavior also compared with the results of the finite element analysis. The good agreement has been achieved between the experimental results and finite element results.

Evaluation of Structural Behavior of Large Studs Using Partial Composite Beams (부분합성보를 이용한 대직경 스터드의 구조거동 평가)

  • Shim, Chang Su;Lee, Pil Goo;Ha, Tae Yul
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.425-432
    • /
    • 2004
  • Large studs were suggested not only for the design of steel-concrete composite bridges with simplified sections but also for the shear connection in precast decks requiring uniform distribution of shear pockets. Based on the push-out test results on studs with diameters of more than 25 mm, partial composite beams with 40%-degree shear connection were fabricated, and static tests were performed. The ultimate strength and horizontal shear load redistribution of partial composite beams, which have parameters of stud shank diameters and distribution, were evaluated, and group failure in the shear span was observed. Since the flexural strength of composite beams are dependent on the strength of their shear connection, the strength of the stud connection was estimated and it showed considerably higher shear strength. From the load-slip curves, the sufficient ductility and load redistribution of large studs were confirmed. Uniformly distributed large studs can provide proper ultimate behavior of composite beams.

Evaluation of Buckling Strength of Surface Plates in Steel-Plate Concrete Walls with Studs and Tie-bars (스터드 및 타이바를 가진 강판콘크리트 벽체의 표면강판 좌굴강도 평가)

  • Koo, Jimo;Lee, Kyungkoo;Kim, Wonki;Lee, JongBo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.129-138
    • /
    • 2016
  • Buckling of surface plates is an important limit state in Steel-Plate Concrete (SC) walls under axial compression. The surface plates may be anchored to concrete using connectors of studs or tie-bars. In this paper, the effects of studs and tie-bars on buckling of surface plates were evaluated by conducting tests. Experiments have three types of connectors; all studs, all tie-bars, and the combination of studs and tie-bars. Also, experiments have the various ratios of stud or tie-bar spacing to surface plate thickness. The experimental investigation shows that the buckling shape and strength of the surface plate of SC wall with the combination of studs and tie-bars have good agreements with that of the surface plate of SC walls with all studs or all tie-bars.

Finite Element Analysis of Deformation Characteristics of the Shear Studs embedded in High Strength Concrete Slab of the Composite Beam (전단스터드의 변형특성에 관한 유한요소해석 -고강도 콘크리트를 사용한 합성보-)

  • Shin, Hyun Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.5
    • /
    • pp.473-482
    • /
    • 2007
  • When the material strength and ductility of shear studs is sufficient to carry the interface shear force, the composite beam can behave safely without premature structural failure in the interface and without ultimate moment reduction. In this study, the influence of the deformation capacity of shear studs embedded in high-strength concrete on structural behavior and design condition of composite beam is analyzed using FEM. In the analysis, load type, degree of shear connection and arrangement of studs are considered as analysis parameters. According to analysis results, in the case of partial interaction,the deformation capacity of studs embedded in high-strength concrete should be considered together with material strength. Especially in the case of uniform arrangement of studs and uniformly distributed load, a minimum available degree of shear connection is restricted by the deformation capacity of studs. In this case,shear studs should be arranged in consideration of the distribution of shear force at the composite section.

Analytical Study for Performance Improvement of Studs for Steel Plate Concrete(SC) Walls subjected to Bending Moment (휨모멘트를 받는 강판 콘크리트(SC) 벽체에서 스터드의 성능개선을 위한 해석적 연구)

  • Cho, Sung-Gook;Lim, Jin-Sun;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • In this study, it was conducted to improve the performance of stud of Steel Plate Concrete(SC) walls subjected to bending moment. Non-linearity of contact interface, connection, and material properties were considered in finite element modeling of SC wall. In order to validate the analytical model, furthermore, a foregoing laboratory experiment was simulated by FEM, so that comparison between the measured result and the analysis result have be done. The size of the analytical model was determined by reflecting various references and the analyses were performed according to various shapes and arrangements of stud. Additionally, the validity of the model considering the related provisions in the KEPIC SNG standard was also considered. As a result, the optimal shape and spacing of studs was proposed through this numerical analysis and standard verification.