• Title/Summary/Keyword: 스크린 X

Search Result 78, Processing Time 0.031 seconds

Fabrication and Electrical Properties of Ni-Mn-Co-Fe Oxide Thick Film NTC Thermistors (Ni-Mn-Co-Fe 산화물 후막 NTC 서미스터의 제조 및 전기적 특성)

  • Park, Kyeong-Soon;Bang, Dae-Young;Yun, Sung-Jin;Choi, Byung-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.912-918
    • /
    • 2002
  • Ni-Mn-Co-Fe oxide thick films were coated on an alumina substrate by screening printing technique. The microstructure and electrical properties of the thick films, as a function of composition and sintering temperature, were investigated. The components of the NTC thick films sintered at 1150${\circ}C$ were distributed homogeneously. On the other hand, in the case of the NTC thick films sintered at 1200 and 1250${\circ}C$, Co element was distributed homogeneously, but Ni, Mn and Fe elements were distributed heterogeneously, resulting in the formation of Ni rich and Mn-Fe rich regions. All the thick film NTC thermistors prepared showed a linear relationship between log resistance (log R) and the reciprocal of absolute temperature (1/T), indicative of NTC characteristics. At a given NiO and $Mn_3O_4$ content, the resistance, B constant and activation energy of $(Ni_{1.0}Mn_{1.0}Co_{1-x}Fe_x)O_4$ (0.25${\le}$x${\le}$0.75) and $(Ni_{0.75}Mn_{1.25}Co_{1-x}Fe_x)O_4$ (0.25${\le}$x${\le}$0.75) thermistors increased with increasing $Fe_2O_3$ content.

Evaluation of Asymetric Film-Screen System (비대칭(非對稱) 필름-스크린 시스템에 관한 검토(檢討))

  • Huh, Joon;Kim, Jung-Min;Lee, Sun-Sook;Lee, In-Ja;Choi, Jong-Hak;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 1993
  • Asymetric system have been introduced in these years by KODAK company nam of Insight system for the purpose of improve the chest image. We have had a problem of chest radiology that it is very difficult to visualize the lung field and modiastinal region at one shot. That's why we are the RT using the technique of high voltage hard quality radiography in chest radiography. Also it is known the c-type wide latitude film can lift up the density of mediastinal structures. Authors investigated the photographic characteristics and physical structure of Insight system. Method 1. Investigated the structure of Emulsion layer. Calculated the particle size of Insight system using SEM(Scanning Electron Microscope). 2. Photographic characteristics has been compared the Insight system with the ortho KM/MG combination in $60{\sim}120kV$ range. Results 1. The particle size of backside film were investigated about 2 times larger that of front side film. 2. The front and backscreen's thickness ratio was detected 1 : 3.87, that the backscreen's thickness was thicker than frontscreen. 3. At the view point of photographic characteristics the frontside of insight system make up the contrast, backside make up the density at low exposure lesion.

  • PDF

Patterning of ITO on Touch Screen Panels using a beam shaped femtosecond laser (빔 쉐이핑된 펨토초 레이저를 이용한 터치스크린 패널의 ITO 박막 패터닝)

  • Kim, Myung-Ju;Kim, Yong-Hyun;Yoon, Ji-Wook;Choi, Won-Seok;Cho, Sung-Hak;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2013
  • Femtosecond laser patterning of ITO on a touch screen panel with a shaped fs laser beam was investigated. A quasi flat-top beam was formed using a variable mask and a planoconvex lens. The spatial profile of the original Gaussian beam and the shaped beam were monitored by a CCD beam profiler. The laser patterned ITO film was examined using an optical microscope, Scanning Electron Microscope (SEM) with Energy Dispersive X-ray Spectroscopy (EDS), and Atomic Force Microscope (AFM). It turned out that the quality of the ITO pattern fabricated by a shaped beam is superior to that of the pattern without beam shaping in terms of debris generation, height of the craters, and homogeneity of the bottom. Optimum processing window was determined at the laser irradiance exhibiting 100% removal of Sn. The removal rate of In was measured to be 83%.

  • PDF

Trends and Outlooks of Mobile Handset on Convergence (컨버전스 진전에 따른 이동통신단말기 동향과 전망)

  • Han, Eok-Su;Sin, Yong-Hui;Jeong, Dong-Heon
    • Electronics and Telecommunications Trends
    • /
    • v.23 no.2 s.110
    • /
    • pp.69-79
    • /
    • 2008
  • 지난 수 년간 이동통신 시장은 그야말로 급격한 변화와 성장을 경험하였다. 특히 휴대폰 시장은 이미 성숙기를 지나 교체수요 시장으로 선회하고 있으며, 기술적 측면에서는 2.5세대(CDMA 1x, GPRS), 3세대(EV-DO, W-CDMA), 3.5세대(HSDPA)로 빠르게 이동하고 있다. 최근 이동통신단말기 분야에서 일어나고 있는 변화의 핵심 요소로 이동통신단말기 산업과 모바일 인터넷 콘텐츠 산업과의 융합 현상을 들 수 있다. 예를 들어 Google의 Android(플랫폼), 마이크로소프트의 Windows Mobile(mobile OS) 등 이 큰 관심을 끌고 있으며, 스마트폰 시장의 형성과 터치스크린폰의 확대 등이 예견되고 있다. 본 고에서는 이러한 융합 현상에 따른 이동통신단말기 산업 및 시장의 일반적 현황을 소개하고, 이동통신단말기와 직접 관련된 단말기의 외관적 요소, User Interface, Mobile OS 및 Platform 등을 중심으로 최근 동향 및 향후 진화방향에 대해 살펴본다.

Evaluation of High Absorption Photoconductor for Application to Auto Exposure Control Sensor by Screen Printing Method (자동노출제어장치 센서적용을 위한 스크린 프린팅 제작방식의 고흡수율 광도전체 특성평가)

  • Kim, Dae-Kuk;Kim, Kyo-Tae;Park, Jeong-Eun;Hong, Ju-Yeon;Kim, Jin-Seon;Oh, Kyung-Min;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • In diagnostic radiology, the use of automatic exposure control device is internationally recommended for diagnosis and optimization. However, if exposed to prolonged radiation is a complicated manufacturing process, there is a problem that occurs decrease of various performance overall brightness sensor, which is commercially available conventional. Therefore, in this study, absorption of X-ray is high, and I want to evaluate the AEC applicability of the sensor of the photoconductor-based production has an easy advantage. Experimental results confirms the possibility of fabrication of the sensor through an increase in the SNR, with the detection efficiency superior, accurate turn-off. In addition, it is confirmed that the experimental results of the transmittance and the latent image, Ghost effect by the light conductor does not appear, in the case of a photoconductor with the exception of the PbO, 80% - and it was confirmed good transmittance of 90%. Therefore, excellent mechanical stability and poor performance due to a change of the doping concentration than the existing products that have been put to practical use, the sensor easy photoconductor based, fabrication and can be applied as AEC sensor is expected.

Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate (Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구)

  • Kwak, Ji-Yeon;Lee, K.B.;Lee, Jong-Man;Park, Tae-Soon;Oh, Pil-Jae;Lee, Min-Kie;Seo, Ji-Suk;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • An imaging plate(IP) detector, a two-dimensional digital radiation detector that can acquire image of radioactivity distribution in a sample, has been applied in many fields; for industrial radiography, medical diagnosis, X-ray diffraction test, etc. In this study, the possibility of IP detector to be used lot measuring radioactivity of sample is explored using its high sensitivity, higher spatial resolution, wider dynamic range and screen uniformity for several kinds radiations. First, the IP detector is applied to measure the surface uniformity for area source. Surface uniformity is measured rapidly and nondestructively by measuring the radioactivity distribution of common standard area source$(^{241}Am)$. Next, the IP is employed to study the possibility of measuring an extremely low-level activity of environmental sample. For this study the screen uniformity, shield effect of background radiation, linear dynamic range and fading effect of the IP detector is investigated. The potato, banana, radish and carrot samples are chosen to measure ultra low-level activity of $^{40}K$ isotope. The efficiency calibration of IP detector is carried out using the standard source.

필름 스피커 적용을 위한 PZT/polymer 복합체의 후막 제조 및 압전 특성 평가

  • Son, Yong-Ho;Eo, Sun-Cheol;Kim, Seong-Jin;Gwon, Seong-Yeol;Gwon, Sun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.346-346
    • /
    • 2007
  • 압전세라믹 재료는 현재 압전 변압기, actuator, transducer, sensor, speaker 등에 광범위하게 이용이 되고 있다. 이 중에서 압전세라믹 소결체를 이용한 스피커의 제조는 가공이 까다롭고, 대형의 크기로 제작 시 소자가 깨지는 등의 많은 제약을 받고 있으며, 저음 특성이 떨어져 응용 범위가 한정되어 있다. 따라서 최근에는 이러한 단점을 극복하기 위하여 세라믹/고분자 복합체를 이용한 필름 스피커를 제작하고자 시도하고 있다. 이러한 세라믹/고분자 0-3형 압전 복합체를 이용할 경우, 제품의 경량화를 실현할 수 있고, 크기나 환경의 영향을 거의 받지 않으므로, 고기능성 스피커로의 응용에 적합할 것으로 보인다. 따라서 본 연구에서는 PZT계의 세라믹와 PVDF, PVDF-TrFE, Polyester, acrylic resin 등의 여러 고분자 물질과의 복합체를 제조하여 압전특성을 평가하였다. 본 실험은 먼저 $(Pb_{1-a-b}Ba_aCd_b)(Zr_xTi_{1-x})_{1-c-d}(Ni_{1/3}Nb_{2/3})_c(Zn_{1/3}Nb_{2/3})_dO_3$ (이하 PZT라 표기)의 최적화 조성을 선택하여, $1050^{\circ}C$에서 소결된 분말을 48시간 ball milling방법 로 약 $1{\mu}m$ 크기로 분쇄하였다. 고분자 물질들은 알맞은 용제들을 선택하여 녹였다. 그 다음 소결된 PZT분말과 고분자를 50:50, 60:40, 65:35, 70:30등의 무게 분율로 혼합하고, 분산제, 소포제 등을 첨가하여 3단 roll mill을 이용하여 충분히 분산시켜 페이스트 (Paste)를 제조하였다. 제조된 페이스트를 ITO가 코팅된 PET필름 위에 스크린 프린팅 법을 사용하여 인쇄하여 $120^{\circ}C$에서 5분간 건조하였다. 코팅된 복합체의 두께는 약 $80{\mu}m$ 정도로 측정되었다. Ag 페이스트를 이용한 상부 전극 형성에도 스크린 프린팅 법을 적용하였다. 이를 $120^{\circ}C$에서 4 kV/mm의 DC 전계로 분극 공정을 수행한 후 전기적 특성을 평가하였다. 유전특성을 조사하기 위해서 LCR meter (EDC-1620)를 사용하였고, 시편의 결정구조는 XRD (Rigaku; D/MAX-2500H)을 통해 분석하였으며, 전자현미경(SEM)을 이용하여 미세구조를 분석하였다. 압전 전하상수$(d_{33})$ 값은 APC 8000 모델을 이용하여 측정하였다. PZT의 혼합비가 증가할수록 비유전율 및 압전 전하 상수 등의 전기적 특성이 증가되었다. 또 여러 고분자 물질 중에서 PVDF-TrFE 수지가 가장 우수한 특성을 보였다. 이는 PVDF-TrFE 수지가 압전성을 나타내기 때문인 것으로 판단되었다.

  • PDF

Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector (형광체 스크린 기반 평판형 X선 검출기 적용을 위한 요오드화수은 필름 광도전체 센서 설계 및 제작)

  • Park, Ji Koon;Jung, Bong Jae;Choi, Il Hong;Noh, Si Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.189-194
    • /
    • 2014
  • In this study, from a new x-ray detector that combines a columnar CsI:Na scintillation layer with a photosensitive mercuric iodide layer was investigated. In this structure, X-rays are converted into visible light on a thick CsI:Na layer, which is then converted to electric charges in a thin $HgI_2$ bottom layer. The thin coplanar mercuric iodide films as a photosensitive converter requiring only a few tens of volts of bias, associated with a thick columnar coating of phosphor layer, were simulated and designed. The results of this research suggest that the new coplanar x-ray detector with a hybrid-type structure can resolve the following problems: high voltage from the a-Se, and low conversion efficiency from the indirect conversion method. The results of this research suggest that the new CsI:Na/$HgI_2$ x-ray detector with a double-layer type structure can resolve the following problems: high voltage from the direct conversion method, and low conversion efficiency from the indirect conversion method.

An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray (산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가)

  • Yoon, Yongsu
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.533-542
    • /
    • 2017
  • In diagnostic radiology, the imaging system has been changed from film/screen to digital system. However, the method for removing scatter radiation such as anti-scatter grid has not kept pace with this change. Therefore, authors have devised the indirect flat panel detector (FPD) system with net-like lead in substrate layer which can remove the scattered radiation. In clinical context, there are many radiographic examinations with angulated incident X-ray. However, our proposed FPD has net-like lead foil so the vertical lead foil to the angulate incident X-ray would have bad effect on its performance. In this study, we identified the effect of vertical/horizontal lead foil component on the novel system's performance and improved the structure of novel system for clinical usage with angulated incident X-ray. Grid exposure factor and image contrast were calculated to investigate various structure of novel system using Monte Carlo simulation software when the incident X-ray was tilted ($0^{\circ}$, $15^{\circ}$, and $30^{\circ}$ from the detector plane). More photons were needed to obtain same image quality in the novel system with vertical lead foil only then the system with horizontal lead foil only. An optimal structure of novel system having different heights of its vertical and horizontal lead foil component showed improved performance compared with the novel system in a previous study. Therefore, the novel system will be useful in a clinical context with the angulated incident X-ray if the height and direction of lead foil in the substrate layer are optimized as the condition of conventional radiography.

Screen-printed carbonaceous matrrials for photocapacitor electrode (스크린 프린터에 의한 광캐패시터용 카본 전극 제작)

  • Choi, Woo-Jin;Kwak, Dong-Joo;Sung, Youl-Moon;Ha, Soon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.411-414
    • /
    • 2009
  • Photo-capacitor electrodes are attracting great attention because of their high capacitance and potential applications in electronic devices. Carbon capacitor, active carbon capacitor and its combination will be fabricated using simple sandwich capacitor electrode method as carbonaceous material on each type of capacitor electrodes with 20 ${\times}$ 15 mm cell size. Carbon/active carbon cell was fabricated using sol-gel process with 120oC dry temperature in l hour and using sintering process with 500oC in 2 hour. The effect of sintering temperature on carbon properties was also investigated with X-ray diffraction technique to get the best sintering temperature. The detail of fabrication process will be explained. Elemental composition in electrode material can be measured using quantitative spectroscopic as and a cyclic voltammetric technique was used to study the combined effects of electrode material and effect of annealing temperature and also time on the capacitance of thermally treated in capacitor electrode. In this work, characterization impedance technique is used to measurement of capacitance and giving complementary results. Active carbon as carbonaceous material has a better capacitance in charge/discharge process with mean thickness $32{\mu}m$ and with particle size $1{\mu}m$ to $4.5{\mu}m$ in 20 ${\times}$ 15 mm sample size of capacitor electrode.

  • PDF