• Title/Summary/Keyword: 스캔 주기

Search Result 46, Processing Time 0.026 seconds

Implant supported prosthesis with high performance polymers using a double scanning method (Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례)

  • Kang, Kyeong-Hwan;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.305-310
    • /
    • 2017
  • Nowadays, the development of dental scanner and CAD/CAM technology can facilitate the fabrication of hybrid prosthesis. Double scanning technique, scanning a trial prosthesis and master model, made it possible to realize virtual design and simplify the laboratory work. Instead of using the metal or zirconia framework with composite, ceramic or denture tooth, the new high performance polymer Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland) as a framework with Polymethyl methacrylate (PMMA) veneering teeth (Visio-lign, Bredent, Senden, Germany) was used in this case. This case report showed an acceptable treatment outcome and satisfaction of patient using Pekkton and Visio-lign. However, long term clinical evaluation is needed.

Gesture-based Table Tennis Game in AR Environment (증강현실과 제스처를 이용한 비전기반 탁구 게임)

  • Yang, Jong-Yeol;Lee, Sang-Kyung;Kyoung, Dong-Wuk;Jung, Kee-Chul
    • Journal of Korea Game Society
    • /
    • v.5 no.3
    • /
    • pp.3-10
    • /
    • 2005
  • We present the computer table tennis game using player's swing motion. We need to transform a real world coordinate into a virtual world coordinate in order to hit the virtual ball. We can not get a correct 3-dimension position of racket in environment that using one camera or simple image processing. Therefore we use Augmented Reality (AR) concept to develop the game. This paper shows the AR table tennis game using gesture and method to develop the 3D interaction game that only using one camera without any motion detection device or stereo cameras. Also, we use a scan line method to recognize gesture for speedy processing. The game is developed using ARtoolkit and DirectX that is popular tool of SDK for game development.

  • PDF

A Study on the Analysis of Multi-beam Energy for High Resolution with Maskless Lithography System Using DMD (DMD를 이용한 마스크리스 리소그래피 시스템의 고해상도 구현을 위한 다중 빔 에너지 분석에 관한 연구)

  • Kim, Jong-Su;Shin, Bong-Cheol;Cho, Yong-Kyu;Cho, Myeong-Woo;Lee, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.829-834
    • /
    • 2011
  • Exposure process is the most important technology to fabricate highly integrated circuit. Up to now, mask type lithography process has been generally used. However, it is not efficient for small quantity and/or frequently changing products. Therefore, maskless lithography technology is raised in exposure process. In this study, relations between multi-beam energy and overlay were analyzed. Exposure experiment of generating pattern was performed. It was from presented scan line by multi- beam simulation. As a result, optimal scan line distance was proposed by simulation, and micro pattern accuracy could be improved by exposure experiment using laser direct imaging system.

대면적 기판 위에서의 서브마이크로미터 주기와 크기를 갖는 홀 패턴 형성을 위한 포토리소그라피 공정 최적화

  • Kim, Do-Hyeong;Bae, Si-Yeong;Lee, Dong-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.244-245
    • /
    • 2010
  • 최근 광전자 분야에서는 미래 에너지 자원에 대한 관심과 함께 GaN 기반 발광다이오드 및 태양전지 연구가 활발히 진행되고 있다. GaN는 높은 전자 이동도와 높은 포화 속도 등의 광전자 소자에 유리한 특성을 가지고 있으나, 고 인듐 함유량과 막질의 우수한 특성을 동시에 구현하는 것은 매우 어렵다. 이를 극복하기 위한 방법으로써 선택 영역 박막 성장법(Selective Area Growth)은 마스크 패터닝을 통해 제한된 영역에서만 박막을 성장하는 방법으로써 GaN의 막질을 향상 시킬 수 있는 방법으로 주목받고 있다. 본 논문에서는 대면적 기판에서 GaN의 막질 향상뿐만 아니라 고인듐 InGaN 박막 성장을 위하여 서브마이크로미터 주기와 크기를 갖는 홀 패턴을 포토리소그라피 공정 최적화를 통해 구현할 수 있는 방법에 대해 논의한다. 그림. 1은 사파이어 기판 위에 선택 영역 박막 성장법을 이용하여 성장한 n-GaN/활성층/p-GaN의 구조를 나타낸 그림이다. 이를 통하여 서브마이크로미터 스케일의 반극성 InGaN면 위에 높은 인듐 함유량을 가지면서도 우수한 특성을 갖는 박막을 얻을 수 있다. 본 실험을 위하여 사파이어 기판 위에 SiO2를 증착한 후 포토레지스트(AZ5206)을 도포하고 포토리소그라피 공정을 진행하여 2um 크기 및 간격을 갖는 패턴을 형성했다. 그림. 2는 AZ5206에 UV를 조사(5초)하고 현상(23초)한 패턴을 윗면(그림. 2(a))과 $45^{\circ}$ 기울인 면(그림. 2(b)) 에서 본 SEM(Scanning Electron Microscope) 사진이다. 이를 통해 약 2.2um의 홀 패턴이 선명하게 형성 됨을 볼 수 있다. 그 후 수백나노 직경의 홀을 만들기 위해서 리플로우 공정을 수행한다. 그림. 3은 리플로우 온도에 따른 패턴의 홀 모양을 AFM(Atomic Force Microscope)을 이용하여 측정한 표면의 사진이다. 이를 통해 2차원 평면에서 리플로우 온도 및 시간에 따른 변화를 볼 수 있다. 그림.3의 (a)는 리플로우 공정을 진행하기 전 패턴이고, (b)는 $150^{\circ}C$에서 2분, (c)는 $160^{\circ}C$에서 2분 (d)는 $170^{\circ}C$에서 2분 동안 리플로우 공정을 진행한 패턴이다. $150^{\circ}C$$160^{\circ}C$에서는 직경에 큰 변화가 없었고, $160^{\circ}C$에서는 시료별 현상 시간 오차에 따라 홀의 크기가 커지는 경향이 나타났다. 그러나 $170^{\circ}C$에서 2분간 리플로우 한 시료 (그림. 3(d))의 경우는 홀의 직경이 ~970nm 정도로 줄어든 것을 볼 수 있다. 홀의 크기를 보다 명확히 표현하기 위해 그림.3에 대응시켜 단면을 스캔한 그래프가 그림.4에 나타나 있다. 그림.4의 (a) 및 (b)의 경우 포토레지스트의 높이 및 간격이 일정하므로, 리플로우에 의한 영향은 거의 없었다. 그림. 4(c)의 경우 포토레지스트의 높이가 그림.4(a)에 비해 ~25nm 정도 낮은 것으로 볼 때, 과도 현상 및 약간의 리플로우가 나타났을 가능성이 크다. 그림. 4(d)에서는 ~970nm의 홀 크기가 나타나서 본 연구에서 목표로 하는 나노 홀 크기에 가장 가까워짐을 확인할 수 있었다. 따라서, $170^{\circ}C$ 이상의 온도와 2분 이상의 리플로우 시간 조건에서 선택 영역 성장을 위한 나노 홀 마스크의 크기를 제어할 수 있음을 확인하였다.

  • PDF

Clinical Effect of Avocado/Soybean Unsaponifiables on Osteoarthritis of the Temporomandibular Joint (측두하악관절의 골관절염 치료에서 Avocado/Soybean Unsaponifiables의 효용성)

  • Kim, Hee-Jin;Park, June-Sang;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.2
    • /
    • pp.185-197
    • /
    • 2006
  • The aim of this study was to investigate the beneficial effect of a daily dose of 300 mg of ASU taken for more than 3 months on the subjects diagnosed as osteoarthritis of temporomandibular joint by RDC/TMD. Total 68 outpatients(15-54y) of female except menopause in Orofacial Pain Clinics of the Pusan National University Hospital were randomly assigned to either an ASU group(n=36) or a placebo group(n=32). The pain, noise and limited mouth opening(LOM) were evaluated by numerical analogue scale(NAS, range 0-10) and maximum comfortable opening(MCO) were measured by milimeter scale. The difference of simple uptake rate(SUR) on bone scan, hot spot(HS) on coronal SPECT, condylar bony changes on CT between the ASU and placebo groups were compared to investigate the objective effect. The obtained results were as follows. 1. Comparison of the NAS of pain, noise, LOM and MCO before treatment and 3, 6 and 9 months after treatment showed no significant difference between the ASU and placebo groups. 2. Comparison of the NAS of pain, noise, LOM and MCO before treatment and 3, 6 and 9 months after treatment showed no significant difference between the ASU and placebo groups without splint treatment, but showed more increased MCO in the ASU group than the placebo group with splint treatment at 6, 9 months after treatment. 3. Comparison of the NAS of pain before treatment and 3, 6 and 9 months after treatment that the NAS of pain at first visit divided into two groups(above or below 6) showed more decreased the NAS of pain in the ASU group than the placebo group that the NAS of pain at first visit was above 6. 4. Comparison of the NAS of pain, noise, LOM and MCO during 6 months period showed improvement of clinical symptoms within group, but no significant difference between subjects. 5. The simple uptake ratio(SUR) on bone scan and hot spot(HS) on coronal SPECT showed more increased SUR and HS in affected side than non-affected side of the ASU and placebo groups. 6. Comparing of condylar bony changes, osseous remodeling were observed highest, osteophyte lowest in the affected and non-affected side of the two groups. After treatment, comparison of condylar bony changes were observed more decreased erosive features in the ASU group than the placebo group.

A Study on Scenario to establish Coastal Inundation Prediction Map due to Storm Surge (폭풍해일에 의한 해안침수예상도 작성 시나리오 연구)

  • Moon, Seung-Rok;Kang, Tae-Soon;Nam, Soo-Yong;Hwang, Joon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.5
    • /
    • pp.492-501
    • /
    • 2007
  • Coastal disasters have become one of the most important issues in every coastal country. In Korea, coastal disasters such as storm surge, sea level rise and extreme weather have placed many coastal regions in danger of being exposed or damaged during subsequent storms and gradual shoreline retreat. A storm surge is an onshore gush of water associated with a tow pressure weather system, typically in typhoon season. However, it is very difficult to predict storm surge height and inundation due to the irregularity of the course and intensity of a typhoon. To provide a new scheme of typhoon damage prediction model, the scenario which changes the central pressure, the maximum wind radius, the track and the proceeding speed by corresponding previous typhoon database, was composed. The virtual typhoon scenario database was constructed with individual scenario simulation and evaluation, in which it extracted the result from the scenario database of information of the hereafter typhoon and information due to climate change. This virtual typhoon scenario database will apply damage prediction information about a typhoon. This study performed construction and analysis of the simulation system with the storm surge/coastal inundation model at Masan coastal areas, and applied method for predicting using the scenario of the storm surge.

Application of the Homogenization Analysis to Calculation of a Permeability Coefficient (투수계수 산정을 위한 균질화 해석법의 적응)

  • 채병곤
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2004
  • Hydraulic conductivity along rock fracture is mainly dependent on fracture geometries such as orientation, aperture, roughness and connectivity. Therefore, it needs to consider fracture geometries sufficiently on a fracture model for a numerical analysis to calculate permeability coefficient in a fracture. This study performed new type of numerical analysis using a homogenization analysis method to calculate permeability coefficient accurately along single fractures with several fracture models that were considered fracture geometries as much as possible. First of all, fracture roughness and aperture variation due to normal stress applied on a fracture were directly measured under a confocal laser scaning microscope (CLSM). The acquired geometric data were used as input data to construct fracture models for the homogenization analysis (HA). Using the constructed fracture models, the homogenization analysis method can compute permeability coefficient with consideration of material properties both in microscale and in macroscale. The HA is a new type of perturbation theory developed to characterize the behavior of a micro inhomogeneous material with a periodic microstructure. It calculates micro scale permeability coefficient at homogeneous microscale, and then, computes a homogenized permeability coefficient (C-permeability coefficient) at macro scale. Therefore, it is possible to analyze accurate characteristics of permeability reflected with local effect of facture geometry. Several computations of the HA were conducted to prove validity of the HA results compared with the empirical equations of permeability in the previous studies using the constructed 2-D fracture models. The model can be classified into a parallel plate model that has fracture roughness and identical aperture along a fracture. According to the computation results, the conventional C-permeability coefficients have values in the range of the same order or difference of one order from the permeability coefficients calculated by an empirical equation. It means that the HA result is valid to calculate permeability coefficient along a fracture. However, it should be noted that C-permeability coefficient is more accurate result than the preexisting equations of permeability calculation, because the HA considers permeability characteristics of locally inhomogeneous fracture geometries and material properties both in microscale and macroscale.

A CT Simulator Phantom for Geometrica1 Test (CT 시뮬레이터의 기하학적 성능평가용 팬톰)

  • Min, Chul-Kee;Yi, Byong-Yong;Ahn, Seung-Do;Choi, Eun-Kyung;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.337-344
    • /
    • 2000
  • Purpose :To design and test test CT simulator phantom for geometrical test. Materials and Methods : The PMMA phantom was designed as a cylinder which is 20 cm in diameter and 24 cm in length, along with a 25$\times25\times31cm^{3}$ rectangular parallelepiped. Radio-opaque wires of which diameter is 0.8 mm are attached on the other surface of the phantom as a spiral. The rectangular phantom was made of four 24$\times24\times0.5 cm^{3}$ square plates and each plate had a 24$\times24 cm^{2}$, 12$\times12cm^{2}$, 6$\times6 cm$^{2}$ square line. The squares were placed to face the cylinder at angles 0 $^{\circ}$ , 15 $^{\circ}$ , 30 $^{\circ}$ ,respectively. The rectangular phantom made it possible to measure the field size, couch angle, the collimator angle, the isocenter shift and the SSD, the measurements of the gantry angle from the cylindrical part. A virtual simulation software, AcOSim, offered various conditions to perform virtual simulations and these results were used to perform the geometrical Quality assurance of CT simulator. Results : A 0.3$\~$0.5 mm difference was found on the 24 cm field size which was created with the DRR measurements obtained by scanning of the rectangular phantom. The isocenter shift, the collimator rotation, the couch rotation, and the gantry rotation test showed 0.5$\~$1 mm, 0.5$\~$l$^{\circ}$ 0.5$\~$ 1$^{\circ}$ , and 0.5-1 $^{\circ}$ differences, respectively. We could not find any significant differences between the results from the two scanning methods. Conclusion :The geometrical test phantom developed in the study showed less than 1 mm (or 1 $^{\circ}$ ) differences. The phantom could be used as a routine geometrical QC/QA tools, since the differences are within clinically acceptable ranges.

  • PDF

A Study on the Quality of Image of Ultrasound Using the Tissue-mimicking Phantom - in some hospitals jeju province (조직등가팬텀을 이용한 임상초음파 영상의 질에 관한 연구 - 제주도 내 병원을 중심으로 -)

  • Yang, Jeong-Hwa;Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.63-69
    • /
    • 2006
  • In diagnostic ultrasound, the quality of image affect to diagnose. To maintain suboptimal imaging uniformly, Quality Assurance of Ultrasound equipment should take periodically. This is article about examination the quality of image in diagnostic ultrasound to understand conditions of probes in hospitals. There is comparative study of convex and linear probes on ultrasound using tissue-mimicking phantom included simulated cysts, echogenic structures. The ultrasonic attenuation coefficient versus frequency of 0.5 dB is representative of normal liver and 0.7 dB is representative of fatty liver condition in ultrasound phantom. There are results of convex probe, 0.5 dB, vertical group, cystic masses, high contrast masses are mostly shown but 0.7 dB, mid level in vertical group, cystic masses and high contrast masses are nearly visible. In linear probe, 0.5 dB, mid level in vertical group, two or four of them are shown in cystic masses and high contrast masses but there are not visible in 11 of cases. 0.7 dB, there are mostly appear under 6 in vertical group, two or four of them show in cystic masses and high contrast masses and there are not shown in 40 of cases, besides. Linear probes in fatty liver condition of ultrasound instrument are not good in the quality of image practically. So there needs to be replace and fix of probes. Actually management of ultrasound probes is inadequate in hospitals. So if there are program of evaluation to check probes periodically in hospitals from establishment of the ultrasound equipment, there will get better image and have a suitable condition of instruments further more.

  • PDF

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.