• Title/Summary/Keyword: 스캔 방향

Search Result 146, Processing Time 0.029 seconds

Absolute Sonar Position on Side Scan Sonar Data Processing (Side Scan Sonar 자료처리에서 수중예인체의 절대위치)

  • Lee, Yong-Kuk;Park, Gun-Tae;Suk, Bong-Chool;Jung, Baek-Hun;Kim, Seong-Ryul
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.467-476
    • /
    • 2003
  • For the seafloor acoustic image mapping of side scan sonar, the beginning step of the procedure is to fix the absolute sonar (tow-fish) position since the sonar is not hull mounted but towed astern. The technical algorithm used to calculate the actual sonar position without any other additional sub-system, i.e., the underwater acoustic position tracking system or the sonar attitude measuring device, was proposed. In the seafloor image mosaic mapping results using the sonar track (not ship track) developed in this study, any ambiguity or inconsistency of seafloor features was not found. The incidental effect from the sonar position determination procedure orients the towing direction of sonar to be smooth, consequently the swath pattern on the across-track direction becomes stable and the blanking phenomenon of the insonification area is reduced conspicuously. This technical method is considered to be an useful tool when applied toother underwater towing vehicle surveys.

Analysis of non-extension line on upper body using 3D scanning (3차원 스캔을 활용한 상체 피부표면의 Non-extension line 분석)

  • Choe, Ji-Yeong;O, Yeom-Gun;Hong, Gyeong-Hui;Seo, Hye-Won;Kim, Si-Jo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.05a
    • /
    • pp.239-242
    • /
    • 2009
  • 최근 3 차원 측정 기술을 활용한 운동 기능성의 향상을 위한 연구가 활발히 진행되고 있다. 그 예로 3 차원 인체 정보를 이용한 의복패턴 제작 시에 필요한 절개선으로 피부상에서 동작 시 늘어나지 않는 선(Lines of Non-Extension, LoNE)을 찾아내어 활용한 연구가 발표된 바 있다. 이러한 LoNE 은 기존 의복구성을 위한 봉제선이나 기능선으로 활용될 때 동작기능성을 저해하지 않는 특징이 있다. 이에 본 연구에서는 스포츠웨어에서 활동성이 큰 상체의 어깨부위에서 Lines of Non-Extension 을 탐색하고자 하였다. 연구 방법으로는 20 대 후반 남성 2 명을 대상으로 체표의 등 부분에서 3cm 간격으로 계측점을 표시한 후 3D 인체 데이터 (Cyberware, WB)를 획득하였다. 측정시의 자세는 팔을 $30^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$ 외전시켰다. 피부 표면에서의 길이 변화는 구획의 크기를 달리하면서 가로, 세로, 사선방향으로 동작에 따라서 측정하였다. 변화량은 정자세($30^{\circ}$)를 기준으로 A 라 하였을 때, 기준자세와의 차이가 가장 큰 변화량을 보인 자세를 B 라 하고 A 와 B 간의 차이로 계산하였다. 연구결과, NASA 의 Biosuit 에서 소개된 Iberall(1970)의 LoNE 중 진동둘레를 포함한 팔 부위와 등, 어깨 부위에서 유사한 라인을 찾았다. 본 연구에서와 같이 구획별 사선방향 피부 변화량을 측정하는 것은 피부면에 숨겨진 인간공학적 의복 기능선을 탐색하는 데 효과적임을 확인하였다.

  • PDF

Prominence and depression recognition of braille characters printed in both sides. (양면 인쇄본 점자의 요철인식)

  • 최미영;홍경호
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.05b
    • /
    • pp.754-757
    • /
    • 2003
  • 본 논문은 시각 장애인을 위해 양면 인쇄된 점자를 디지털 카메라나 스캐너를 통해서 읽어 들인 후, 영상 내의 잡음과 같은 미세 정보를 제거하는 전처리과정을 거친다. 스캔한 영상을 이진화하기 위해 임계값을 이용한 클리핑으로 이진영상을 만든 후 영상의 특징을 추출한다. 추출된 특징을 보면 점자의 앞면과 뒷면으로 분류할 수 있다. 점자 앞면의 특징이 아래반원으로 나타나며 이러한 특징을 이용한 검출필터를 만들어 점자의 앞면만을 추출해낸다. 점자의 앞면을 추출하는 과정에서 탐색구간을 두어 한 점에 대하여 여러 화소가 검출되는 것을 막는다 영상을 각각 수직방향, 수평방향으로 투영시켜 점자영상 분할을 위한 거리를 계산, 자간격과 줄간격을 구해 1/2되는 지점에 선을 그어 분할한다. 분할된 점자 형태소를 낱자로 인식한다.

  • PDF

Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

A Phantom study of Displacement of Three Dimensional Volume Rendering for Clinical Application in Radiation Treatment Planning (방사선치료계획의 임상적용을 위한 3차원 볼륨렌더링영상 체적변화의 모형연구)

  • Goo, Eun-Hoe;Lee, Jae-Seung;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.280-288
    • /
    • 2009
  • This study is to design and produce a detailed model for volume variety of three dimensional reconstruction images and to evaluate the changes of volume, area and the length of the model in the process of the reconstruction of RTP system. CT simulation was operated at the thickness of 1.25, 2.5, 5, 10mm and average, standard deviation of scan direction(X), thickness(Y), table movement direction(Z), area(A), and volume(V) of the three dimensional volume rendering, were measured according to the shape and thickness of the phantoms. As a result, at the thickness of 1.25, 2.5min, the phantom's shape decreased maximum 0.13cm(p<0.05) to the direction of X, Y, Z and length, area, volume decreased 0.1cm, $0.8cm^2$, $3.99cm^3$ which led to an approximate image of the phantoms. However, at the thickness of 5, 10mm, the phantom of the original form decreased maximum 0.58cm(p<0.05) and volume, area, length decreased maximum 0.45cm, $8.21cm^2$, $11.03cm^3$. Volume varieties according to the thickness and shape of the phantoms have occurred diversely, when CT simulation was operated, and it is considered that a clinically appropriate volume rendering can be obtained only when the thickness is below 3mm.

Design Technique for Wide Swath SAR TOPS imaging Mode (광역관측을 위한 영상레이더 TOPS 모드 설계 기법)

  • Kim, Se-Young;Sung, Jin-Bong;Yi, Dong-Woo;Shim, Sang-Heun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.5
    • /
    • pp.466-471
    • /
    • 2015
  • In this paper, the design technique of the wide swath TOPS(Terrain Observation by Progressive Scan) imaging mode is introduced. The TOPS mode overcomes the scalloping limitations imposed by ScanSAR mode by steering the antenna pattern along track direction during the acquisition of a burst. This paper reports the operation concept of TOPS imaging and mode design result to extract the SAR operational parameters. Finally, several analyzed results such as IRF(Impulse Response Function), NESZ(Noise Equivalent Sigma Zero) and DTAR(Distributed Target Ambiguity Ratio) are presented.

An Efficient Pixel Value Prediction Algorithm using the Similarity and Edge Characteristics Existing in Neighboring Pixels Scanned in Inverse s-order (역 s-순으로 스캔된 주변 픽셀들에 존재하는 유사성과 에지 특성을 이용한 효율적인 픽셀 값 예측 기법)

  • Jung, Soo-Mok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.1
    • /
    • pp.95-99
    • /
    • 2018
  • In this paper, we propose an efficient pixel value prediction algorithm that can accurately predict pixel value using neighboring pixel values scanned in reverse s-order in the image. Generally, image has similarity with similar values between adjacent pixel values, and may have directional edge characteristics. In this paper, we proposed a method to improve pixel value prediction accuracy by improving GAP(Gradient Adjacent Pixel) algorithm for predicting pixel value by using similarity between adjacent pixels and edge characteristics. The proposed method increases the accuracy of the predicted pixel value by precisely predicting the pixel value using the positional weights of the neighboring pixels. Experiments on real images confirmed the superiority of the proposed algorithm. The proposed algorithm is useful for applications such as reversible data hiding, reversible watermarking, and data compression applications.

Nondestructive Evaluation Technique of Painted Sandwich Control Surfaces of CN-235 using Full-field Pulse-echo Ultrasonic Propagation Imaging System (전영역 펄스-에코 초음파전파영상화 시스템의 CN-235의 도색된 샌드위치 조종면 In-situ 비파괴평가 기술)

  • Hong, Seung-Chan;Lee, Jung-Ryul;Park, Jongwoon
    • Composites Research
    • /
    • v.29 no.5
    • /
    • pp.288-292
    • /
    • 2016
  • In this paper, a novel ultrasonic propagation imaging system, called a full-field pulse-echo ultrasonic propagation imaging (FF PE UPI) system is introduced. The system nondestructively inspected targets with two-axis translation stage. The coincident laser beams for ultrasonic sensing and generation are scanned and pulse-echo mode laser ultrasounds are captured. This procedure makes it possible to generate full-field ultrasound in through-the-thickness direction as large as the scan area. Structural inspection results in the form of full-field ultrasonic wave propagation videos are introduced, which are painted sandwich control surfaces. In addition, the inspection results of FF PE UPI system are compared with conventional ultrasonic testing methods such as waterjet and portable C-scan.

A Facial Animation System Using 3D Scanned Data (3D 스캔 데이터를 이용한 얼굴 애니메이션 시스템)

  • Gu, Bon-Gwan;Jung, Chul-Hee;Lee, Jae-Yun;Cho, Sun-Young;Lee, Myeong-Won
    • The KIPS Transactions:PartA
    • /
    • v.17A no.6
    • /
    • pp.281-288
    • /
    • 2010
  • In this paper, we describe the development of a system for generating a 3-dimensional human face using 3D scanned facial data and photo images, and morphing animation. The system comprises a facial feature input tool, a 3-dimensional texture mapping interface, and a 3-dimensional facial morphing interface. The facial feature input tool supports texture mapping and morphing animation - facial morphing areas between two facial models are defined by inputting facial feature points interactively. The texture mapping is done first by means of three photo images - a front and two side images - of a face model. The morphing interface allows for the generation of a morphing animation between corresponding areas of two facial models after texture mapping. This system allows users to interactively generate morphing animations between two facial models, without programming, using 3D scanned facial data and photo images.

Compression of 3D color integral images using 2D referencing technique (2차원 참조 기법을 이용한 3D 컬러 집적 영상의 압축)

  • Kim, Jong-Ho;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2693-2700
    • /
    • 2009
  • This paper proposes an effective compression method to utilize the 3D integral image with large amount of data obtained by a lens array in various applications. The conventional compression methods for still images exhibit low performance in terms of coding efficiency and visual quality, since they cannot remove the correlation between elemental images. In the moving picture compression methods, 1D scanning techniques that produce a sequence of elemental images are not enough to remove the directional correlation between elemental images. The proposed method effectively sequences the elemental images from an integral image by the 2D referencing technique and compresses them using the multi-frame referencing of H.264/AVC. The proposed 2D referencing technique selects the optimal reference image according to vertical, horizontal, and diagonal correlation between elemental images. Experimental results show that compression with the sequence of elemental images presents better coding efficiency than that of still image compression. Moreover, the proposed 2D referencing technique is superior to the 1D scanning methods in terms of the objective performance and visual quality.