• Title/Summary/Keyword: 스캔 디자인

Search Result 59, Processing Time 0.027 seconds

A case of removable dentures using digital method (디지털 방식을 이용하여 제작한 양악 가철성 의치 수복 증례)

  • Lee, Ji-Soo;Ahn, Su-Jin;Leesungbok, Richard;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.250-257
    • /
    • 2018
  • Generally dentures are manufactured by conventional method, however the frequency of fabricating denture using digital method is increasing due to the recent development of digital technology in dentistry. The digital method of manufacturing denture is classified into two systems; 3D scan of the impression to arrange the artificial teeth on the CAD (Computer-aided design) and 3D printing to produce the resin-based complete denture, or 3D scan of the model to design of the framework using CAD, resin pattern formation by 3D printing and casting of metal framework of complete denture or removable partial denture. In this case report, electronic surveying and design the metal framework of the dentures were performed using CAD program, and plastic resin patterns fabricated by 3D printing were casted for upper full denture and lower removable partial denture. During follow-up periods, dentures using digital method have provided satisfactory results esthetically and functionally.

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

Full mouth rehabilitation of a patient with occlusal plane discrepancy with milling machine for clinic (진료실용 밀링머신을 이용한 교합평면 부조화 환자의 완전 구강 회복술)

  • Park, Ji-Man
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.68-78
    • /
    • 2016
  • Recently, digital technology has become increasingly prevalent in the dental clinic. Using a milling machine for clinic, it is possible to produce provisional restoration inside the clinic. This can promote large clinical cases such as full mouth rehabilitation with the help of a tabletop scanner, which is capable of semi-adjustable articulator equipment, and a powerful dental CAD software with excellent user convenience. In this case report, a full-mouth rehabilitation was done with digital technology to a 55 year-old female patient, who has lost vertical dimension through the attrition, and has got inclined occlusal plane with unplanned and repeated dental reconstruction. Through the design and milling of the provisional restoration in the clinic and the duplication of these provisionals by double scanning technique, a good functional and esthetic result could be achieved.

A Study on the simulation software of tapestry in textile design (타피스트리 제작 시뮬레이션 소프트웨어 개발 연구)

  • 손은하;김성곤
    • Archives of design research
    • /
    • v.15 no.1
    • /
    • pp.359-368
    • /
    • 2002
  • Fabric art is most distinguished field among the Modern art. Among them, tapestry which begins human history is investigated more and more deeply and till now it displays with various type and exhibition. But, because of the huge scale of the working process, it requires much time and hard endeavor. After sampling, it begins main process in the present situation. But we cannot know exactly whether it goes well or not until it ends. So after fulfilled whole process, we often try new work again. Because of this reason, we devise computer simulation. With computer simulation we can preview whole working and lengthen the planning time, shorten the needless time. Simulation is made up of Scan, Drawing, Line clean up, Rendering, Parity, and Printing. Scan and Drawing can male new idea. And during the Line clean up we can make vector image and modify the image. And then rendering the image and inquiring the length and weight of yarn. Last process is printing an then making a package soft ware by means of prototype. Through these process, many producers and student can easily access to tapestry and reduce the needless time and endeavor.

  • PDF

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Editorial Design for Effective Research Report of Excavating Cultural Properties (효과적인 문화재발굴조사보고서를 위한 편집디자인)

  • Byun, Ji-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.11
    • /
    • pp.167-174
    • /
    • 2007
  • We are depending on tedious work by hand with tremendous time and effort in order to measure drawing of relics and remains despite of advanced computer and editing technology. Also, it is necessary to improve a designing element in the research report of cultural properties although we have more editorial and technical skills than we have done. The purpose of this article is to help to develop an aesthetic element and measurement of drawing of relics and remains for the effective editing in the current cultural properties research report. At the same time, through the gradual improvement of 3D scan and photographing techniques, research report of cultural properties will create database with useful and valuable material and provide aesthetic and efficient information.

3D Modeling Product Design Process Based on Photo Scanning Technology (포토 스캐닝 기술을 기반으로 한 3D 모델링 제품디자인 프로세스에 관한 연구)

  • Lee, Junsang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.11
    • /
    • pp.1505-1510
    • /
    • 2018
  • Product modeling technology for graphics is rapidly developing. And 3D data application and usability are increasing.modeling of product design is a very important factor in constructing. 3D modeling in product design takes a lot of production time. Recently, the reverse design method is very useful because of application of 3D data and shortening of production time. In this study, first, 3D point cloud and mesh data are generated using photographs based on image data. The second is to modify the design and the third is to make the prototype with the 3D printer. This product design and production process suggests the utilization and possibility of image data, the shortening of 3D modeling production time and efficient processes. Also, the product design process proposes a model of a new product development system to adapt to the production environment.

Case Study Analysis of Digital Education Design to Basic Concept Design Trend by Target of Education Needs in UK and Sweden (디지털 교육매체의 기초 컨셉디자인 동향 파악을 위한 선진국 사례 분석 - 영국과 스웨덴의 사용자 니즈를 중심으로 -)

  • Kim, Jung-Hee
    • Cartoon and Animation Studies
    • /
    • s.34
    • /
    • pp.345-366
    • /
    • 2014
  • From the beginning of Digital text book in 2007, there are many kinds of digital text book such as English, Science etc at Public education. Above many problems at the beginning like just using paper text book's scan data as digital text book, now use special contents and design for only digital text book. But only for digital text book not for other. There is gap between advanced country of education and us. This is research based on LG europe design center in London, UK target is UK, Sweden by heuristic analysis, question investigation to get Target's UX with digital education media. Advancement of digital and interest of education bring the world development of digital education device. UK, where is education advanced nation, is using lot's of digital education device which is interactive board, digital desk etc. Result of Analysis of Digital Education Design trend by Target of Education Needs apply rough Design by LG europe design center. We can get more sophisticated needs and UX result by target then Korea that can use for our future Digital education design plan. Also help to reduce gap between advanced country and Korea.

Cr-Co removable partial denture treatment fabricated by selective laser melting: a case report (Selective Laser Melting을 이용한 코발트-크롬 가철성 국소의치의 수복 증례)

  • Yim, Ji-Hun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.39-47
    • /
    • 2021
  • Compared to conventional method, if metal framework of removable partial denture is fabricated by selective laser melting, various laboratory works are omitted, saving time and simplifying the process. In addition, metal framework with homogeneous density can be obtained, expecting excellent mechanical properties, especially resistance to fatigue fracture. In these cases, impression were taken using conventional methods in partial edentulous patients, master casts were fabricated and scanned to obtain digital data. After designing the metal frameworks on the scanned data, removable partial dentures were fabricated using selective laser melting methods. Through these procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.