• 제목/요약/키워드: 스캐닝 프로브

검색결과 8건 처리시간 0.023초

스캐닝 프로브를 이용한 미지의 자유곡면 점군 획득에 관한 연구 (Digitization of Unknown Sculptured Surface Using a Scanning Probe)

  • 권기복;김재현;이정근;박정환;고태조
    • 한국정밀공학회지
    • /
    • 제21권4호
    • /
    • pp.57-63
    • /
    • 2004
  • This paper describes a method for digitizing the compound surfaces which are comprised of several unknown feature shapes such as base surface, and draft wall. From the reverse engineering's point of view, the main step is to digitize or gather three-dimensional points on an object rapidly and precisely. As well known, the non-contact digitizing apparatus using a laser or structured light can rapidly obtain a great bulk of digitized points, while the touch or scanning probe gives higher accuracy by directly contacting its stylus onto the part surface. By combining those two methods, unknown features can be digitized efficiently. The paper proposes a digitizing methodology using the approximated surface model obtained from laser-scanned data, followed by the use of a scanning probe. Each surface boundary curve and the confining area is investigated to select the most suitable digitizing path topology, which is similar to generating NC tool-paths. The methodology was tested with a simple physical model whose shape is comprised of a base surface, draft walls and cavity volumes.

OMM 시스템의 측정오차 원인분석 및 대책 (The Error Source Analysis of Measuring Data of OMM System)

  • 이상준;김선호;김옥현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.73-77
    • /
    • 1997
  • This paper describes the analysis of measuring error of on the machine measuring(OMM) system which can directly measure the three dimensional machined free surface dimension using scanning probe on milling machine. 21 inch TV shadow mask mould was measured using PTP(point to point)measurement algorithm at pallet clamped and unclamped state on OMM system, and using coordinate measuring machine(CMM) one after another. The OMM system was evaluated probe error, stylus contact error, center shift error, repeatability and so on. Consequencely, the conclusion derived that elastic displacement of pallet had effect on measuring error mainly, and pallet design and setup method would be important.

  • PDF

침투 공격 검출을 위한 비대칭 신호 스캐닝 기법 (Asymmetric Signal Scanning Scheme to Detect Invasive Attacks)

  • 양다빈;이가영;이영우
    • 스마트미디어저널
    • /
    • 제12권1호
    • /
    • pp.17-23
    • /
    • 2023
  • 보안 설계 방법론은 물리적 공격으로부터 집적회로를 방어하는 것을 목적으로 하며, 칩 외부에서 발생하는 비정상적인 접근을 감지하는 회로를 내부에 추가로 배치하여 구현된다. 비정상적인 접근 중 microprobing과 FIB 장비를 이용한 회로 수정 공격은 직접적인 접근이 가능한 만큼 가장 강력한 공격 수단이다. microprobing은 프로브를 통해 회로의 와이어에 의도적으로 결함을 주입하거나, 데이터를 읽고 변경한다. FIB 회로 수정 공격은 회로를 재연결하거나 파괴하여 회로를 무력화하거나 데이터에 접근하는 방식이다. 기존에는 두 공격에 대응하기 위해 두 신호의 도착 시간 불일치를 검출하거나, 암호화 통신을 기반으로 입출력 데이터를 비교하는 연구가 진행됐었다. 본 논문에서는 하드웨어 오버헤드 감소를 목표로 연구를 진행했으며, 프로브 접촉과 회로 수정을 통해 발생하는 반사 신호의 비대칭을 감지한 후, 비교를 통해 공격을 검출한다. 제안하는 보안 회로는 기존 연구 대비 회로의 크기와 테스트 주기를 감소시켜, 보안에 사용되는 비용을 절감할 수 있다.

역공학에서 센서융합에 의한 효율적인 데이터 획득 (Efficient Digitizing in Reverse Engineering By Sensor Fusion)

  • 박영근;고태조;김희술
    • 한국정밀공학회지
    • /
    • 제18권9호
    • /
    • pp.61-70
    • /
    • 2001
  • This paper introduces a new digitization method with sensor fusion for shape measurement in reverse engineering. Digitization can be classified into contact and non-contact type according to the measurement devices. Important thing in digitization is speed and accuracy. The former is excellent in speed and the latter is good for accuracy. Sensor fusion in digitization intends to incorporate the merits of both types so that the system can be automatized. Firstly, non-contact sensor with vision system acquires coarse 3D point data rapidly. This process is needed to identify and loco]ice the object located at unknown position on the table. Secondly, accurate 3D point data can be automatically obtained using scanning probe based on the previously measured coarse 3D point data. In the research, a great number of measuring points of equi-distance were instructed along the line acquired by the vision system. Finally, the digitized 3D point data are approximated to the rational B-spline surface equation, and the free-formed surface information can be transferred to a commercial CAD/CAM system via IGES translation in order to machine the modeled geometric shape.

  • PDF

스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술 (position marking technique for data measured in a scanning hall probe system)

  • 유재은;이재영;정예현;이상무;염도준
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.

고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징 (Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo)

  • 조한샘;장선주;오왕열
    • 한국광학회지
    • /
    • 제25권2호
    • /
    • pp.67-71
    • /
    • 2014
  • 혈관 내 OCT (optical coherence tomography) 는 혈관 벽 내부의 3차원적 미세구조를 영상화할 수 있어서 임상에서 각광을 받고 있다. 하지만 아직도 충분하지 못한 이미징 속도, 특히 내시경 프로브의 이미징 광 스캐닝 속도의 부족으로 혈관 길이 방향의 이미징 간격이 실제 시스템의 광학적 해상도보다 5배 이상 커서 혈관 종방향으로의 고해상도 이미징이 얻어지지 못하고 있는 상황이다. 본 논문에서는 초당 350장의 혈관 벽 단층 영상을 제공하는 고속 혈관 내 OCT 시스템을 기술한다. 본 시스템과 내시경 장치를 이용하여 47 mm 길이의 살아있는 토끼 대동맥을 3.7초만에 34 micron의 혈관 종방향 간격으로 얻는데 성공하였다. 34 micron의 종방향 간격은 실제 내시경의 그 방향 광학적 해상도와 비슷한 정도로서 3차원 모든 방향으로의 고해상도 이미징을 구현하였음을 보여준다. 얻어진 이미징 데이터의 3차원 영상 구현을 통해 혈관의 미세구조 및 이미징 전 삽입된 스텐트의 자세한 구조를 보였다.