• Title/Summary/Keyword: 스마트 최상층 면진시스템

Search Result 3, Processing Time 0.015 seconds

Performance Evaluation of Vibration Control of a Smart Top-Story Isolation System (스마트 최상층 면진시스템의 진동제어 성능평가)

  • Kang, Joo-Won;Kim, Tae-Ho;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.3
    • /
    • pp.49-56
    • /
    • 2010
  • In this study, the control performance of a smart top-story isolation system for tall buildings subjected to wind excitation was investigated. To this end, a 77-story tall building structure was employed and wind loads obtained from wind tunnel test were used for numerical simulations. The top-story of an example structure is separated from the main structure by a smart base isolation system composed of friction pendulum systems (FPS) and MR dampers. The primary purpose of the smart top-story isolation system is to mitigate the dynamic responses of the main structure, but the excessive movement of the isolated top story may cause the unstableness of the building structure. Therefore, the skyhook control algorithm was used to effectively reduce both responses of the isolated top story and the main structure. The control performance of the proposed smart top-story isolation system was investigated in comparison with that of the passive top-story isolation system. It has been shown from numerical simulation results that the smart top-story isolation system can effectively reduce wind-induced responses of the example building structure compared to the passive top-story isolation system with reduction of the top-story movement.

  • PDF

Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity (중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.13-20
    • /
    • 2013
  • In order to reduce seismic responses of a structure, additional dampers and vibration control devices are generally considered. Usually, control performance of additional devices are investigated for optimal design without variation of characteristics of a structure. In this study, multi-objective integrated optimization of structure-smart control device is conducted and possibility of reduction of structural resources of a building structure with smart top-story isolation system has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions. The integrated optimal design method proposed in this study can provide various optimal designs that presents good control performance by appropriately reducing the amount of structural material and damping device.

Investigation of Adaptability of Smart Top-Story Isolation System to Structures in Regions of Low-to-Moderate Seismicity (스마트 최상층 면진시스템의 중약진지역 적용성 평가)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.4
    • /
    • pp.71-80
    • /
    • 2012
  • Because a smart isolation system cannot be used as a base isolation system for tall buildings, top-story or mid-story isolation systems are required. In this study, adaptability of a smart top-story isolation system for reduction of seismic responses of tall buildings in regions of low-to-moderate seismicity has been investigated. To this end, 20-story example building structure was selected and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes generated based on design spectrum of low-to-moderate seismicity regions are used for structural analyses. Based on numerical simulation results, it has been shown that a smart top-story isolation system can effectively reduce both structural responses and isolation story drifts of the building structure in low-to-moderate seismicity regions in comparison with a passive top-story isolation system.