• Title/Summary/Keyword: 순환식

Search Result 1,042, Processing Time 0.033 seconds

Evaluation of Limestone for In-Situ Desulfurization in CFB Boilers (순환유동층 보일러 로내 탈황을 위한 석회석 평가)

  • Lee, See Hoon;Kim, Dong Won;Lee, Jong Min;Bae, Yong Chae
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.853-860
    • /
    • 2019
  • In order to meet more severe environmental regulations, oxy-fuel circulating fluidized bed(CFB) boilers or ultra supercritical CFB boilers, which are a kind of process in that solid particles moves similar to fluid, have been developed in the world. In CFB power generation processes, the method to reduce or remove sulfur dioxide is in-situ desulfurization reaction via limestone directly injected into CFB boilers. However, the desulfurization efficiencies have continuously changed because limestones injected into CFB boilers are affected by various operation conditions (Bed temperature, pressure, solid circulating rate, solid holdup, residence time, and so on). In this study, a prediction method with physical and chemical properties of limestone and operation conditions of CFB boiler for in-situ desulfurization reaction in CFB boilers has developed by integrating desulfurization kinetic equations and hydrodynamics equations for CFB previously published. In particular, the prediction equation for in-situ desulfurization was modified by using experimental results from desulfurization reactions of various domestic limestones.

Simulating Stratified Reservoir Mixing by a Convection Circulator (대류 순환식 폭기장치에 의한 성층화된 저수지 혼합 모의)

  • Lee, Yo-Sang;Lee, Gwang-Man;Koh, Deuk-Goo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.469-473
    • /
    • 2009
  • 저수지에서 잠재적 대규모 조류발생을 감소시키기 위하여 인공적 성층파괴 장치가 2006년 용담댐에 설치되었다. 본 연구는 저수지에서 여름철 발생하는 성층파괴에 대한 대류순환식 폭기장치의 효과를 검토하기 위해 수행되었다. 성층파괴 장치의 성능을 분석하기 위하여 반경 25m, 높이 45m의 실린더 용기에 34.6만개의 격자로 구성된 CFD모형을 적용하였다. 적용결과, 사면체 격자는 온도와 유속에서 실측자료와 밀접하게 일치하였다. 이와 같은 결과는 난류확산항이 제거되었을때 보다 태양광 열전도를 고려한 경우가 보다 좋은 결과를 보였다. 결과적으로 성층파괴 장치의 지속적인 운영은 인공적 외부력을 통하여 성층화된 수체를 혼합시키는데 유용할 것으로 나타났으나 현재 설치되어 있는 장비로는 크기나 숫자에서 충분하지 못해 원래 목적을 달성하기에는 부족한 것으로 나타났다.

  • PDF

Changes of Plant Growth and Nutrient Concentrations of the Drainage According to Drainage Reuse and Substrate Type in Sweet Pepper Hydroponics (파프리카 수경재배 시 배액 재사용과 배지 종류에 따른 생육 및 배액 내 이온 농도 변화)

  • Lim, Mi Young;Jeong, Eun Seol;Roh, Mi Young;Choi, Gyeong Lee;Kim, So Hui;Lee, Choung Keun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.476-484
    • /
    • 2022
  • This study was conducted to investigate the effect of closed cultivation and open cultivation method and substrate type on the nutrient ion change pattern and growth of sweet pepper (Capsicum annuum L.) 'Scirocco' according to the reuse of drainage in hydroponics. The sowing, transplanting, and application of the closed and open cultivation method were carried out on August 19 and September 16, and October 21, 2021, respectively. As a result of the analysis of nutrients in the drainage, Na+ and Cl- are representative ions that crops do not absorb properly, and as the growth progresses, they are accumulated in the closed method. In addition, since the content of NH4-N in the drainage is significantly lower than that of NO3-N, it is thought that NH4-N is preferentially absorbed rather than NO3-N due to the ion selectivity of sweet pepper. The growth and fruit characteristics of sweet pepper did not differ significantly between treatments according to the drainage reuse and the type of substrate. In conclusion, if you take care of poor fruiting due to the weakening of power after the middle period in hydroponic cultivation of sweet pepper according to the cultivation method of closed and open, and the substrate type of coir and rock wool, the difference between treatments is not large, so the sweet pepper can be produced by selecting the cultivation methods and substrate types suitable for the conditions of grower. However, as interest in environmental pollution has recently increased, it is judged that there is no need to worry about a decrease in quantity or quality, even if a closed cultivation method is adopted under the assumption that pathogen infection due to drainage reuse is well managed. It is expected that if coir is applied instead of rock wool, which causes a problem of disposal, it will further contribute to the reduction of environmental pollution.

The Effects of Task-Oriented Circuit Training on The Upper Extremity Function and Quality of Life in Chronic Stroke Patients (유비쿼터스 의료환경에서 순환식 과제 지향적 훈련이 뇌졸중 환자의 상지 기능과 삶의 질에 미치는 영향)

  • Lee, Gue-Dong;Kim, Young-Hun;Moon, Jong-Hoon;Park, Kyung-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.3
    • /
    • pp.651-660
    • /
    • 2018
  • The purpose of this study was to investigate the effects of task-oriented circuit training(: TOCT) on upper extremity function and quality of life in chronic stroke patients. 20 stroke patients were randomized and divided into 2 groups: a preservation therapy group and TOCT group. The intervention sessions were given five times a week for four weeks. The Stroke Impact Scale(: SIS), EuroQual-5Domains(: EQ-5D), Fugl-Myer Assessment(: FMA), Motor Activity Log(: MAL), Canadian Occupational Performance Measure(: COPM) were used to measure the upper extremity function and the quality of life. In results, Two groups improved in upper extremity function after the intervention(p<.05). The EQ-5D scores of TOCT group were a significantly higher than preservation group(p<.05). The Ironing, Folding towels, Hang out towels on drying rack in COPM scores in both of performance and satisfaction have improved more than preservation group(p<.05). In conclusion, the TOCT has significant helpful effect to chronic stroke patients. These findings can be used to chronic stroke patient as an intervention for upper extremity function and quality of life.

Solid Circulation Characteristics in a 3 kW Chemical-looping Combustor (3 kW급 매체순환식 가스연소기의 고체순환특성)

  • Ryu, Ho-Jung;Park, Jaehyeon;Kim, Hong-Ki;Park, Moon-Hee
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1057-1062
    • /
    • 2008
  • To overcome disadvantages of conventional two interconnected fluidized beds system, a novel two-interconnected fluidized bed process has been adopted to 3kW chemical-looping combustor. This system has two bubbling beds, solid injection nozzles, solid conveying lines, and downcomers. In this study, effects of operating variables such as gas velocity through the solid injection nozzle, fluidizing velocity, solid height, geometry of solid intake hole, bed temperature on solid circulation rate have been investigated in a 3kW chemical-looping combustor. The solid circulation rate increased as the solid height and the opening area of solid intake holes increased. The effect of the fluidizing velocity and the bed temperature were negligible. Moreover, long-term operation of continuous solid circulation up to 50 hours has been performed to check feasibility of stable operation. The pressure drop profiles in the bubbling beds and the downcomers were maintained steadily and solid circulation was smooth and stable.

Reaction Characteristics of Oxygen Carrier Perticle for Chemical-Looping Combustor in Fixed Bed and Pressurized Fluidized Bed (고정층과 가압유동층에서 매체순환식 가스연소기 산소공여입자의 반응특성)

  • 류호정;배달희;진경태
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.173-177
    • /
    • 2002
  • 두 개의 유동층 사이를 순환하는 금속매체(Metal or Metal oxide)를 이용하여 공기에 의한 금속매체의 산화와 기체연료(H$_2$, CO, CH$_4$등)에 의한 금속산화물의 환원반응이 별개의 반응기에서 일어나게 하는 새로운 개념의 연소기술인 매체순환식 가스연소기술은 공기와 기체연료를 직접 접촉시켜 반응하는 기존의 가스연소기에 비해 많은 장점을 가지고 있다.(중략)

  • PDF

Evaluation of Infiltration Trench Effects on Hydrologic Cycle in a Urbanized Watershed (침투 트렌치 시설이 도시유역 물순환에 미치는 영향 평가)

  • Noh, Seong-Jin;Kim, Hyeon-Jun;Jang, Cheol-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.715-719
    • /
    • 2006
  • 청계천 유역에 침투 트렌치 설치시 영향을 분포형 모형인 WEP 모형을 통하여 평가하였다. 침투 트렌치는 홍수 저감 보다는 물순환 개선에 효과가 있으나, 갈수량 증가량이 대부분 합류식 하수관에 의해 배제되는 것으로 모의되었다. 물순환 개선을 위해서는 침투 트렌치 설치에 앞서 합류식 하수관 시설의 재정비 등 유역내 저류량이 하천으로 이어질 수 있도록 하는 노력이 필요할 것으로 판단된다.

  • PDF

Changes of Nutrient Content of Circulating Solution in Three Different New Hydroponics for Oriental Melons(Cucumis melo L. var. makuwa Mak.) (참외용 수경재배시스템에서의 순환배양액의 무기이온 함량의 변화)

  • 조익환;전하준
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.168-174
    • /
    • 2002
  • A new circulating hydroponic system was invented for oriental melons grown in the greenhouse. For developing nutrient solution management techniques, we examined the changes of nutrient contents of circulating solution in three different types of new hydroponic systems. The yield and fruit quality of oriental melons in Hydroponics were better than those in soil culture. The substrate culture was appropriate fer hydroponics of oriental melons, and NFT was turned to be the opposite due to the physiological disorder during hot seasons. Yamazaki's melon solution with EC 2.0dS.m$^{[-10]}$ was the most appropriate for oriental melons. The new circulating hydroponic system seemed to be appropriate for oriental melons because of the stable EC, pH and the macro- and micro-element contents. NO$_3$-N, Ca and Mg contents in the circulating solution kept a good balance in all types of hydroponics. However, p content, compared to other types, decreased by the degree of 1 me.L$^{[-10]}$ in perlite medium. K content showed irregular status in perlite but showed the stable status in cocopeat. Generally, microelements, except Mo, showed stable absorption in the substrate culture. However, in NET, most of the elements showed irregular absorption except B and Mn. Microelement absorption, especially Cu, Zn and Mo, decreased during hot seasons.

Changes in Nutrient Element Concentrations and Growth of Cucumber Plants (Cucumis sativus L. cv. Joeun Baegdadagi) as Affected by Nutrient Solution Composition in Recirculating Hydroponic Systems (순환식 수경재배시 배양액조성에 따른 배양액 양분농도 변화 및 오이 생육)

  • Roh, Mi-Young;Choi, Gyeong-Lee;Rhee, Han-Cheol;Seo, Tae-Cheol;Kim, Wan-Soon;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.363-369
    • /
    • 2009
  • This experiment was conducted to find out the effect of nutrient solution composition on the growth of cucumber plants and the changes in macro-elements in nutrient solutions in recirculating hydroponic systems. Cucumber plants (Cucumis sativus L. cv. Joeun Baegdadagi) were grown in closed perlite cultivation systems supplied with different nutrient solutions developed by NHRS (National Horticultural Research Station in Japan), Yamasaki, PBG (Proefstation voor Bloemisterij en Glasgroente), and NIHHS (National Institute of Horticultural and Herbal Science in Korea). The concentrations of $NO_{3^-}N$, $Ca^{2+}$, $Mg^{2+}$, and $SO_{4^-}S$ in the recycled nutrient solutions increased but that of $NH_{4^-}N$ decreased gradually in all the treatments. The $PO_{4^-}P$ and $K^+$ concentrations were continuously reduced from the beginning of the harvest to the harvest peak period. There were no significant differences in the concentrations of $NO_{3^-}N$, $NH_{4^-}N$, and $Ca^{2+}$ in the recirculated nutrient solutions among four treatments, while the concentrations of $PO_{4^-}P$ and $K^+$ were lowest and those of $Mg^{2+}$ and $SO_{4^-}S$ were highest in the treatment of Yamasaki's nutrient solution. All growth-related parameters of cucumber plants except for leaf number were not significantly affected by the nutrient solution compositions. Due to its low concentrations of $PO_{4^-}P$ and $K^+$ in the recycled nutrient solution, however, the number and yield of cucumber fruits were lowest in the treatment of Yamasaki's nutrient solution.