• Title/Summary/Keyword: 숙련도시험

Search Result 49, Processing Time 0.022 seconds

Evaluation of proficiency and improvement of accuracy on the analysis of brominated flame retardants (PBDEs) in ABS polymer (ABS수지 중 polybrominated diphenyl ether(PBDE)류 분석 숙련도 평가 및 정확도 향상)

  • Ryu, Jehoon;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.446-452
    • /
    • 2015
  • In order to evaluate and improve the ability of Korean testing laboratories to measure Polybrominated diphenyl ethers in acrylonitrile-butadiene-styrene (ABS), a proficiency test was organised by Korea Research Institute of Standards and Science (KRISS) based on ISO/IEC 17043. The proficiency test material used was 10 g of a granular ABS fortified with a mixture of congeners of PBDE (BDE-154, 183, 206, 209). Homogeneity and stability were investigated to assess the adequacy of the test material. The certified value established by KRISS based on the national reference was used for assigned value of each PBDE. The test materials were distributed to the 16 participating laboratories. The participating laboratories were requested to analyse the samples employing the methods used in their routine analysis. Each laboratory was given it’s own code to secure the anonymity. Participants results were evaluated with z-scores according to ISO/IEC 17043. The standard deviation for proficiency assessment was set by standard deviation of the participants results except for outlier. The results, the laboratory's performance and improvement of accuracy were discussed.

Establishment of National Quality Control System for Analytical Laboratory of Pesticide Products by Proficiency Testing (농약 이화학시험 분석기관의 숙련도시험을 통한 정도관리체계 확립 연구)

  • Chang, Hee-Ra;Park, Hyo-Kyung;Lim, Youngjoo;Kim, Kwang-Ho;Kim, Chan Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.350-356
    • /
    • 2012
  • Performance of proficiency testing and the validation of analytical method was included a scheme of quality assurance in analytical chemistry laboratory to monitor a laboratory's performance abilities and produce consistently reliable data. This study was assessed the applicability of proficiency testing scheme proposed for analytical laboratories of pesticide product in domestic. The validation of analytical methods, stability and homogeneity for formulated pesticide products (emulsifiable concentrate) of emamectin benzoate and lufenuron was confirmed for the proficiency testing. The z-score of 33 participation laboratories for emamectin benzoate were that the numbers of outlier were 2 laboratories (6.0%), z-score outside the range from -3 to 3 designated "unaccptable" were 2 laboratories and z-score in the ranges -2 to -3 and 2 to 3 designated "questionable" were 3 laboratories (9.0%). Three laboratories (9.0%) showed the z-score designated "questionable" for lufenuron. The additional proficiency testing for various product types will be needed to establish the scheme of quality control.

Evaluation of the proficiency testing results for brominated flame retardants in high impact polystyrene (고충격폴리스티렌 중 브롬계 난연제 숙련도시험 결과 평가)

  • Kim, Dal-Ho;Ryu, Je-Hoon;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.435-442
    • /
    • 2011
  • Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants (BFRs) which have taken much interest recently due to their potential hazardous effects to human body and ecosystem. Many countries and European community prohibits the usage of certain BFRs in electronics and electronic devices (e.g. RoHS). In this perspectives, Korea Research Institute of Standards and Science (KRISS) has designed and practiced proficiency testing programs based on the ISO/IEC 17043 in order to assist laboratory accreditation activities. The programs for interlaboratory comparisons include congeners of PBDE (PBDE-154, 183, 206, 209) in high impact polystyrene (HIPS). A sample bottle that contains 10 g granular HIPS was distributed to 35 participating laboratories and the test results were calculated by the statistical procedure using z-scores to evaluate performance of each laboratory. The results and the laboratory's performance were discussed.

정보통신기기 지정시험기관 숙련도시험 프로그램의 도입에 관한 연구

  • 김태용;배장근;박태식;허봉재;서동환;조규보;윤경효
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.116-123
    • /
    • 2004
  • 대부분의 국가에서는 생산제품의 적합성. 평가를 위해 인정기구를 통한 시험기관 인증제도를 운영하고 있으며, 세계 표준화 기구들과 상호 연계하여 표준화 및 관리 제도를 운영하고 있다. 국내의 경우 정보통신부 전락연구소는 정보통신기기에 대해 분야별로 시험 기관 인증(지정)제도를 운영하고 있으며 이에 대한 사후관리 업무도 수행하고 있다.(중략)

Proficiency Testing by Inter-Laboratory Comparisons for Braking Lining (제동 라이닝애 대한 시험소간 비교에 의한 숙련도시험)

  • Chung Jong-Duk;Kwon Sung-Tae;Hong Yung-Ki;Kim Won-kyung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.586-591
    • /
    • 2003
  • This paper describes the result of proficiency testing by inter-laboratory comparisons for braking lining. Proficiency testing provides an objective means of assessing and demonstrating the validity and reliability of test results produced by laboratories. To more accuracy comparison test for braking lining test, they will be made the same test procedure and environment conditions.

  • PDF

Preparation and assessment of airborne fibrous reference sample for a proficiency test (국내 공기 중 섬유상 분진 숙련도 시험용 표준시료 제조 및 평가)

  • Lim, Hoju;Ryu, Jaihyuk;Choi, Sungho;Choi, Arum;Jung, Hyunsung;Ryu, Jungmin;Kim, Hyunwook;Jang, Seongki
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.369-375
    • /
    • 2009
  • We evaluated the homogeneity and accuracy of low level airborne fibrous standard, and accomplished the proper proficiency test. We had found that the correlation of concentration of standard solution and asbestos density was 0.9863~0.9968, and concluded that the proper guideline of the analysis result was ${\mid}Z{\mid}{\leq}2$ interval of Z-score.

A Study on Proficiency Comparison Testing Between Testers Using ISO/IEC 25023 Software Quality Characteristics Evaluation (ISO/IEC 25023 소프트웨어 품질 특성 평가를 이용한 시험자간 비교시험에 관한 연구)

  • Lee, Chang-Hee;Kim, Myung-Sup;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.18-27
    • /
    • 2020
  • This study compared and analyzed the results of proficiency testing between testers based on the international standard ISO/IEC 17043 proficiency testing requirements using ISO/IEC 25023 software quality characteristics evaluation. Application of the test was submitted to the KASTO as a software test in the electric test field defined by KOLAS. Among ISO/IEC 25023, the evaluation items for proficiency testing between testers were selected as functional completeness and time behavior. The comparison test between testers was carried out on May 28, 2019 at the accredited LG Electronics SW Laboratory in Seoul and attended by KOLAS assessors. The test evaluation method was measured once per tester with functional completeness, and measurement was repeated 10 times per tester according to time behavior. As a result, in the case of functional completeness, all 12 test steps were passed, and the satisfaction was evaluated. Time behavior was repeated 10 times, and the mean was 9.45 ± 0.01 seconds for testers 1 and 3 and 9.52 ± 0.0 seconds for tester 2, but there was no statistically significant difference. In conclusion, the proficiency of the testers was equal, and the reliability of the test results of the test institute was confirmed.

Proficiency Testing for the HPLC Analysis of Azoxystrobin, Imidacloprid and Methabenzthiazuron Residues in Soil (HPLC를 이용한 아족시스트로빈과 이미다클로프리드, 메타벤즈티아주론의 토양 잔류분석 숙련도시험)

  • Kim, Chan-Sub;Son, Kyeong-Ae;Gil, Geun-Hwan;Im, Geon-Jae
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.218-229
    • /
    • 2015
  • The proficiency testing for the residue laboratories of pesticide registration was conducted in order to improve the reliability and the ability for pesticide residue analysis. On November 2012 the testing was carried out using the soil collected and kept as the moistened state for five years, which was expected to very low residue levels of pesticides. The soil was fortified with azoxystrobin, imidacloprid and methabenzthiazuron in a manner similar to prepare soil samples for indoor soil degradation test, and then sub-samples were prepared for the distribution to participants. Some of them were randomly selected for confirm of homogeneity and to ensure the stability of samples at room temperature. Samples were consisted of two soils treated as different levels, one of which was used to the assessment and another used to confirm. In addition, provided three standard solutions, respectively concentration of 10 mg/L, and untreated soil. Forty eight institutions submitted results. The medians of results were used as the assigned values for pesticide residues. Fitness for purpose standard deviation of proficiency test was calculated by applying 20% RSD as the coefficient of variation allowed in the soil residue test. Z-score was applied for evaluation of individual pesticides, and the average of the absolute value of the Z-score for the overall assessment of pesticides. Laboratories evaluated the absolute value of the Z-score less than 2 to fit the case of azoxystrobin were 48, imidacloprid and methabenzthiazuron 46.