Characterization of Thermal Properties of Concrte and Temperature Prediction Model (콘크리트재료의 열특성 및 수화열 해석)

  • 양성철
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.2
    • /
    • pp.121-132
    • /
    • 1997
  • The thermal behavior of' concrete can be ch;lracterized from a knowledge of concrete ternperatu1.e at early ages, environmental conditions, and cement hydration in the mixture. 'l'o account for thost. interactions, a computer model was developed for prwlicting the temperature pr.ol'ile in hnrdcning c o n c r c t ~ st.r~icture in terms of material and tmvironmcntal factors. The cerncnt hydration cha~.acteristics such as the activating energy, total heat 1ihei.atr.d. anti th\ulcorner degree of' hydration. can represent the internal heat gc,neration. In this study. th(> activating c1ncrgy and the tlcgree of' hydration curve were determined well fmm the rnortn~. compressive strength tests while total amount of heat liberated was determined by tht> isothermal calorimctcr method. The main purpose of' this study is to correlate measured tt>mperaturr distributions in a concrete st1,ucture during thc hardening process with the ~ c s u l t s computed f'ro~n theoretical considrl.ations. Using twodimensional heat transfer model, first. the importance of several parameters will be identified by a parametric analysis. Then, the tcmpcmture distribution of thc cylindrical concrete specimen in the laboratory was mensuwti and compared with that yielded by thc theoretical considel.ations.

Synthesis and Characterization of Comb-Type Grafted Polymer Hydrogels with Low Temperature Sensitivity (저온 감열 특성을 가지는 Comb-Type Grafted Polymer Hydrogels의 합성 및 특성평가)

  • Taek Kyu Jung;Sung Soo Kim;Byung Cheol Shin
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The comb-type grafted polymer hydrogels, which composed of N-isopropylacrylamide monomer and oligo(N-isopropylacrylamide-co-tert-butylacrylamide) [oligo(NIPAAm-co-t-BAM)], were synthesized by redox polymerization in 5~10% methanol aqueous solution using ammonium peroxodisulfate (APS) at 4 oC for 24h. The lower critical solution temperatures (LCSTs) of the comb-type grafted hydrogels were decreased with increase of t-BAM content in the grafted copolymer. We observed the effect of crosslinker and concentration of oligo(NIPAAm-co-t-BAM) on the shrinking/swelling ratio of hydrogels. Changes of shrinking/swelling ratio were decreased with increase of concentration of crosslinker. The increase of grafted oligo(NIPAAm-co-t-BAM) in the hydrogel shows an fast changes of shrinking/ swelling rate. The comb-type grafted hydrogels are expected to be valuable for the sensing materials of time-temperature labels(TTLs).

Effect of Freezing on Hydration Rate and Sprouting Characteristics of Soybeans (대두의 수화속도와 콩나물의 발아특성에 대한 동결처리 효과)

  • Rhim, Jong-Whan;Oh, Bong-Yun;Kim, Dong-Han;Ham, Kyung-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.660-665
    • /
    • 2003
  • Effect of freezing on the hydration rate and growth characteristics of bean sprout of two domestic cultivars of soybean, Eunha beans and Taegwang beans, was investigated. Freezing of the soybeans at $-80^{\circ}C$ affected characteristics of the hydration and growth of soybean sprout of the beans. Hydration rate of the frozen beans depended on the hydration temperature. It decreased up to 50% at lower than $60^{\circ}C$ of hydration temperature, but it did not decrease at higher than $60^{\circ}C$. Activation energies of frozen Eunha and Taegwang beans were 39.79 and 39.25 kJ/mol, respectively. Kinetic compensation effect between activation energy values and the pre-exponential factor for the hydration of soybeans with or without freezing was observed. Germination rate and thickness of the bean sprout increased by freezing, however, yield and weight were not affected by freezing.

Evaluation of Hydration Heat of Mass Concrete with Capsulated Slurry PCM and FEM Study for Analyzing Thermal Crack (캡슐형 슬러리 PCM을 혼입한 매스콘크리트의 수화열 평가 및 온도균열 FEM 해석에 관한 연구)

  • Park, ChangGun;Kim, Bo-Hyun;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.379-388
    • /
    • 2014
  • The purpose of this study is to investigate the effect of capsulated slurry phase change material (PCM) on the thermal crack in mass concrete by experimental work and FEM analysis. In this study, three conditions of samples were prepared for evaluating the level of hydration heat, i.e., a material condition, a cement paste condition and a concrete condition. Also, a compressive strength test was conducted for FEM inverse analysis. Based on the results of the experiment, exothermic function coefficients of concrete with encapsulated slurry PCM were deducted by the inverse analysis. After that, they applied to FEM analysis of the mass scale concrete structures. From the results of this experiment, $31^{\circ}C$ capsulated slurry PCM had no super cooling phenomenon in the material condition. In the cement condition, hydration heat decreased by 34.61J when PCM of 1g was mixed. In the concrete condition, PCM of 6% was deducted as the best level in hydration heat absorption. In FEM inverse analysis, rate coefficient of reaction gradually decreased when PCM mixing ratio increased. But, temperature-rise coefficient increased when PCM mixing ratio exceeded 6%. For the inversed exothermic function coefficients applying to large scale concrete structures, a thermal cracking index increased by 0.05 when PCM of 1% was mixed.

Hydration Heat Control of Marine Pier Foundation using Low-Heat Cement and Mesh Form (저발열 콘크리트와 Mesh형 거푸집을 이용한 교각기초의 수화열 저감 방안 연구)

  • Cho, Yong-Yeon;Lee, Won-Joon;Won, Jong-Hwa;Kim, Tae-Min;Kim, Moon-Kyum
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.315-318
    • /
    • 2009
  • 본 논문에서는 해상 기초 교각 매스 콘크리트의 수화열 저감 방안을 다루었다. 저발열 콘크리트, Mesh형 거푸집 공법 등에 대한 실험을 수행하여 각각의 수화열 저감효과를 평가하였다. 현장 실험은 사용 시멘트와 거푸집의 종류, 거푸집의 사용 면수에 따라 총 4 type으로 구성하였으며, 이에 대한 실험 결과와 유한 요소 해석 결과를 비교, 검증하여 최종적인 수화열 저감 성능을 도출하고자 하였다. 실험을 통해, 저발열 시멘트와 유로폼을 사용하는 것이 수화열 저감을 위해 효과적인 방법으로 판명되었으나 추가 공사비의 발생으로 효율성이 떨어질 것으로 판단된다. 또한 Mesh형 거푸집 적용 면 수와 온도 상승 저감 효과는 비례하는 것을 알 수 있었지만 내 외부 온도차가 다소 크게 나타나 수화열에 의한 균열 발생 확률면에서는 다소 불리하게 나타났다. 그러나 실험 단계에서 생략된 양생과 관리를 통하여 균열의 저감효과를 거둘 수 있을 것으로 판단되며, 추가적으로 거푸집 해체 단계를 생략함으로 공기단축 측면에서 유리할 것으로 판단된다.

  • PDF

An Experimental study on the Thermal Stresses in the Massive Abutment of Bridge (교량교대구조물의 수화열 및 온도응력에 대한 실험적 연구)

  • Kwon, Ki-Jun;Kim, Dong-Baek
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.2 s.21
    • /
    • pp.1-7
    • /
    • 2006
  • Recently, the massive concrete structures have been increasingly built in Korea. Many reinforced concrete structures have been reported to suffer from cracking in construction stages due to heat of hydration arising from mass concrete. This cracking may cause some serious durability problems and thus reduces the safety and service life of the structures. In this study, the stresses, strains, and temperatures were measured and the crack widths and crack Patterns were also observed in the footing and abutment structures. And the causes and mechanism in thermal cracking in the footing and abutment structures are thoroughly analysed. The comparisons of test results with analysis have been made. Efficient crack control techniques were developed form the experimental and analytical studies.

Determination of Degree of Hydration, Temperature and Moisture Distributions in Early-age Concrete (초기재령 콘크리트의 수화도와 온도 및 습도분포 해석)

  • 차수원;오병환;이형준
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.813-822
    • /
    • 2002
  • The purpose of the present study is first to refine the mathematical material models for moisture and temperature distributions in early-age concrete and then to incorporate those models into finite element procedure. The three dimensional finite element program developed in the present study can determine the degree of hydration, temperature and moisture distribution in hardening concrete. It is assumed that temperature and humidity fields are fully uncoupled and only the degree of hydration is coupled with two state variables. Mathematical formulation of degree of hydration Is based on the combination of three rate functions of reaction. The effect of moisture condition as well as temperature on the rate of reaction is considered in the degree of hydration model. In moisture transfer, diffusion coefficient is strongly dependent on the moisture content in pore system. Many existing models describe this phenomenon according to the composition of mixture, especially water to cement ratio, but do not consider the age dependency. Microstructure is changing with the hydration and thus transport coefficients at early ages are significantly higher because the pore structure in the cement matrix is more open. The moisture capacity and sink are derived from age-dependent desorption isotherm. Prediction of a moisture sink due to the hydration process, i.e. self-desiccation, is related to autogenous shrinkage, which may cause early-age cracking in high strength and high performance concrete. The realistic models and finite element program developed in this study provide fairly good results on the temperature and moisture distribution for early-age concrete and correlate very well with actual test data.

A Statistical Analysis on Hydration Heat and Autogenous Shrinkage of High Strength Concrete in Early Age Using Blast Furnace Slag (고로슬래그 미분말을 다량 사용한 고강도 콘크리트의 초기 수화발열 및 자기수축 특성에 관한 통계적 분석)

  • Koo, Kyung-Mo;Nam, Jeong-Soo;Lee, Eui-Bae;Kim, Young-Duck;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.657-660
    • /
    • 2008
  • In this study, quantitative analysis on effect of hydration heat and autogenous shrinkage of concrete using BFS was studied. Especially, it analyze section data statistically which hydration heat and autogenous shrinkage rise, and it appeared the correlation of hydration heat and autogenous shrinkage as well as quantitative coefficients of the main properties. As a result, the section which hydration heat and autogenous shrinkage of BFS-50 rise rapidly is delayed than OPC, but the slope of hydration heat and autogenous shrinkage in that section appeared similar shape in each mixing. Finally it will be possible to control the amount of autogenous shrinkage because hydration heating velocity and autogenous shrinking velocity are decreased by using BFS.

  • PDF

Refinement of Phosphogypsum by Selective Dehydration & Hydration (수화특성차이(水和特性差異)를 이용(利用)한 인산부생석고(燐酸副生石膏)로부터 정제석고(精製石膏)의 회수(回收))

  • Lee, Jung-Mi;Song, Young-Jun;Park, Charn-Hoon
    • Resources Recycling
    • /
    • v.15 no.3 s.71
    • /
    • pp.46-57
    • /
    • 2006
  • This study was carried out for the purpose of recovering the refined gypsum from waste phosphogypsum. The refined gypsum was recovered as a under product of 325 mesh wet screening followed by dehydration and hydration stage. The influence of dehydration temperature and time, dehydration rate, aging time, slurry density of hydration and sonication time on the yield and grade of gypsum were investigated. The refined gypsum of $94{\sim}96%$ grade is recovered in 95% yield by wet screening after selective dehydration and hydration process, from the phosphogypsum. For the better separation efficiency of gypsum, it is recommended to treat the phosphogypsum at the conditions of as follows; 6hr's dehydration at $140^{\circ}C$, hydration slury density of $3{\sim}10%$, hydration temperature of $20{\sim}30^{\circ}C$, hydration time of 2hr. In additions, addition of sodium citrate 0.005M and sonication of $5{\sim}10min.$ are effective for increase the recovery of gypsum. On the other hand, aging the dehydrated gypsum 16 hours or longer make decrease the recovery of gypsum remarkably.

Hydration Heat Properties of High Flowing Self-Compacting Concrete with Normal Strength (보통강도 고유동 자기충전 콘크리트의 수화발열 특성)

  • Choi, Yun-Wang;Kim, Byoung-Kwon;Lee, Jae-Nam;Ryu, Deug-Hyun;Song, Yong-Kyu;Jung, Woo-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.497-500
    • /
    • 2008
  • This research carries out experiments for hydration exothermic rate and adiabatic temperature rise of concrete to examine the characteristics of the hydration heat of high flowing self-compacting concrete with a normal strength. As a result of the hydration exothermic rate experiment, the high flowing self-compacting concrete that used Lime stone powder and fly ash as polymers shows that its hydration heat amount reduces due to the reduction of unit cement. The result measured the adiabatic temperature rise of concrete presents that high flowing self-compacting concrete having lots of binder contents has a good performance in temperature reduction due to the effect of polymer and that triple adding high flowing self-compacting concrete has a similar temperature rise speed with conventional concrete. As a result of the research, high flowing self-compacting concrete shows a better temperature reduction performance for the binder content per unit than conventional concrete. In addition, it is judged that triple adding high flowing self-compacting concrete with a specified concrete strength 30 MPa is more beneficial in temperature reduction and early hydration heat than double adding high flowing self-compacting concrete.

  • PDF