• Title/Summary/Keyword: 수치해석 모델

Search Result 3,113, Processing Time 0.035 seconds

Tow Dimensional Hydrodynamic Study in the Bay by a Mathematical Model (수치모델에 의한 만내의 2차원 동수력학 해석)

  • 한건연;김정역
    • Water for future
    • /
    • v.15 no.4
    • /
    • pp.45-53
    • /
    • 1982
  • The mathematical simulation of tow-dimensional hydrodynamic analysis in the bay was studied. The basic equations of the model consisted of the momentum equations and the continuity equation, and they were analysed by the finite difference method. The Leendertse's multi-operation method was used to solve the equations. For the numerical analysis, the computer program was made to get the velocity distribution was within the range of 10cm/sec and the currents were mainly in the north-south direction, which had a good agreement with the observed data. The methodological procedure made in this paper will provide a basic contribution to hydrodynamic study in the bay.

  • PDF

수치모델을 이용한 월성원전 인근저수지의 삼중수소방사능 해석과 응용

  • Kim, Jong-Yeop;Jeong, Jin-Uk;Kim, U-Gon;Jeong, Seong-Il;Lee, Byeong-Il
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.112-113
    • /
    • 2009
  • 원전주변 환경방사능측정 시료 중 다른 시료와 다르게 저수지는 방사능축적 경향을 확인할 수 있는 가능성이 매우 높다. 본 논문에서는 문제해석의 단순화를 위해 여러 가정의 전제하에 원전주변 저수지의 삼중수소농도계산이 가능한 수치모델을 제안하고 그 결과를 통해 환경방사능 해석에 필요한 값들을 제공하는 방법을 제안하였다. 환경방사능 해석에 제공될 수 있는 값들로는 저수지의 삼중수소농도의 포화여부, 저수지 인근의 삼중수소 농도, 원전으로부터 삼중수소 방출율의 추정, 저수지에 대한 모니터링의 필요성 등이 포함된다.

  • PDF

열분해 반응기 내에서의 Si 오염입자에 관한 수치해석적 연구

  • U, Dae-Gwang;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.363-363
    • /
    • 2011
  • 열분해 반응기 내에서 실리콘 필름을 성장시키는 것은 반도체/디스플레이, 태양전지, 신소재 등 다양한 분야에서 중요한 공정이다. 더욱이 반도체 소자 선폭이 줄어들면서 나노입자의 오염 제어가 더불어 중요해지고 있다. 생산 공정 기술의 집적화에 따라 패턴 사이 거리가 작아지고, 이에 불과 수 십 나노미터크기의 오염입자에 의해서 패턴불량이 발생하고 생산수율을 감소시킨다. 일반적으로 반도체 공정 중 발생한 오염입자는 반응기 내의 가스가 물리/화학적 공정에 의해 핵생성(nucleation)이 일어나 핵(nuclei)이 생성되고, 이 때 표면반응 및 응집(coagulation)에 의해 성장하게 된다. 이에 본 연구에서는 열분해 반응기 내에서 사일렌(SiH4) 가스를 열분해하여 발생되는 실리콘 오염입자의 핵생성과 성장 모델을 정립하고, 생성된 오염입자의 거동과 전달 현상을 이론적으로 고찰하였다. 열분해 반응기와 같은 기상공정(Gas to particle conversion)에서 오염입자가 생성될 때, 그 성질과 크기 등에 물리/화학적 영향을 주는 요소는 전구체/이송기체의 농도 및 유량, 작동 압력, 작동 온도와 반응기 고유 특성 등이 있다. 수치해석의 정당성과 빠른 계산을 위해 단순화시킨 0D 모델인 Batch 반응기와 1D모델인 plug flow 반응기 등에서 SiH4 가스의 열분해 과정시 생성되는 Si cluster를 상용코드인 CHEMKIN 4.1.1을 이용하여 계산하였으며, 2D모델인 Shear flow 반응기로 확장시켜 Si 오염입자가 생성특성을 연구하였다.

  • PDF

Numerical Analysis and Experimental Measurement of Hygroscopic Warping Effects for Cellulose Fibres (셀룰로스 복합소재에서의 수분에 의한 뒤틀림 변형효과를 위한 수치해석적 실험적 연구)

  • Kim, Byeong-Sam;Kim, Ki-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.117-123
    • /
    • 2004
  • The prediction to the hydroscopic moisture warping behaviors is analyzed for cellulose-based laminates using a numerical method base on a modified classical laminate(MCL) theory for hygroscopic moisture deformations with cycling testing data. The experimental measurement of the interferometric hygroscopic warping effects, moisture generator, and curvature of cellulose reinforced epoxy laminates is studied under cyclic environmental conditions using a Moire interferometer coupled. Accurate determination of curvatures provides a description of dimensional stability evolution; the tools for validation of computational internal stress and for the warpage prediction in model safety.

An Improved Finite Element for Structural Analysis of Cable-Supported Structures (케이블 지지구조물의 구조해석을 위한 개선된 유한요소)

  • 김선훈;최창근;송명관
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.2
    • /
    • pp.117-125
    • /
    • 2001
  • 본 논문에서는 케이블 지지구조물의 비선형 정적해석과 동적해석에 사용할 수 있는 개선된 유한요소가 제시되었다. 케이블의 모델화를 위해 등가탄성계수를 사용하고 처짐곡선을 현수선함수로 가정한 케이블요소가 제안되었다. 프레임 부재에 사용되는 안정함수는 수치적으로 안정한 해를 얻기 위하여 수정되었다. 본 논문에서 제안한 요소의 유용성과 효율성을 검토하기 위하여 다양한 검증문제에 대한 수치해석이 수행되었다. 해석결과 본 논문에서 제시한 유한요소는 케이블 지지구조물의 모델화에 매우 유용하고 효율적으로 사용될 수 있을 것으로 판단된다.

  • PDF

Numerical Analysis of Weldment by Considering the Convection of Welding Arc and Weld Pool (용접 아크 및 용융 풀의 유동을 고려한 용접부 수치 해석)

  • 김원훈;나석주
    • Journal of Welding and Joining
    • /
    • v.15 no.1
    • /
    • pp.26-35
    • /
    • 1997
  • 본 연구에서는 GTAW 및 GMAW 공정에서 용접부의 열 및 물질유동해석을 수행하기 위한 지배방정식, 해석방법 및 절차를 제시하였으며, 또 실제로 해석한 결과를 에제로 살펴보았다. 그러나 용접공정은 매우 복잡한 물리적 현상을 야기하기 때문에 용접부 수치해석 모델 설정 및 해석의 수행은 용이한 일은 아니다. 그렇지만 이 분야의 연구는 용접 구조물에 대해서 사전에 용접조건 설정을 위한 실제 용접 작업 수행을 하지 않고 용접부 형상, 결함, 냉각속도, 응고 등의 예측을 위한 매우 효과적이고 경제적인 방법으로 사료되기 때문에 용접 분야에 종사하는 관련 연구자들의 관심이 한층 더 요망된다.

  • PDF

아트리움 공간에 있어서 화재에 의한 연기 유동에 관한 수치해석적 연구

  • 노재성;유홍선;정연태
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.43-48
    • /
    • 1997
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire modus: Zone model and Field model. The zone mode used is the CFAST(version 1.6) mode developed at the Building and Fire Research laboratories, NIST in the USA. The lied model is a self-developed fire field model based on Computational Fluid Dynamics(CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. A computational procedure for predicting velocity and temperature distribution in fro-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i. e. Zone model and Field model predicted similar results for Ire clear height and the smoke layer temperature.

  • PDF

A Study of the Effect of Grouting Region on the Solution of Line Source Analysis (그라우팅 영역이 선형열원 해석에 미치는 영향에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.143-150
    • /
    • 2010
  • Line source method of borehole system assumes the entire surrounding medium is uniform. However, thermal properties of grouting region are considerably different from those of surrounding soil. In this study we investigate the effect of grouting materials on the solution of line source method with the aid of numerical analysis. This numerical model generates the temperature of borehole fluid with which line source solution can be obtained. Then this solution can be compared with input condition of numerical model. The results of this comparison show that thermal conductivity and borehole thermal resistance of line source solution are approximately 86% and 91% of the input condition of numerical model. Chart method is developed in this study to find the numerical input conditions (thermal conductivity and borehole thermal resistance) from the line source solution. Thermal response test of test borehole is conducted, the results of which are approximately consistent with the Chart method. Thermal property changes of grouting materials on the line source solution are also examined.

Numerical Study of Hybrid Base-isolator with Magnetorheological Damper and Friction Pendulum System (MR 감쇠기와 FPS를 이용한 하이브리드 면진장치의 수치해석적 연구)

  • Kim, Hyun-Su;Roschke, P.N.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.7-15
    • /
    • 2005
  • Numerical analysis model is proposed to predict the dynamic behavior of a single-degree-of-freedom structure that is equipped with hybrid base isolation system. Hybrid base isolation system is composed of friction pendulum systems (FPS) and a magnetorheological (MR) damper. A neuro-fuzzy model is used to represent dynamic behavior of the MR damper. Fuzzy model of the MR damper is trained by ANFIS (Adaptive Neuro-Fuzzy Inference System) using various displacement, velocity, and voltage combinations that are obtained from a series of performance tests. Modelling of the FPS is carried out with a nonlinear analytical equation that is derived in this study and neuro-fuzzy training. Fuzzy logic controller is employed to control the command voltage that is sent to MR damper. The dynamic responses of experimental structure subjected to various earthquake excitations are compared with numerically simulated results using neuro-fuzzy modeling method. Numerical simulation using neuro-fuzzy models of the MR damper and FPS predict response of the hybrid base isolation system very well.

An Analytical Study on the Condensation of Submerged Vapor Jets in Subcooled Liquids (과냉수에서의 증기응축제트에 대한 해석적 연구)

  • 김기웅;이계복;김환열
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.333-340
    • /
    • 1999
  • A numerical study of turbulent condensing vapor jet submerged in subcooled liquids has been conducted. A physical model of the process is presented employing the locally homogeneous flow approximation of two phase flow in conjunction with a $\kappa$-$\varepsilon$-g model of turbulence properties. In this model the turbulence is represented by differential equations for its kinetic energy and dissipation. A differential equation for the concentration fluctuations is solved and a clipped normal probability distribution function is proposed for the mixture fraction. Effects of steam mass flux, pool temperature and nozzle internal diameter on the condensing vapor jet are also analyzed. The model is evaluated using existing data for turbulent condensing vapor jets. The agreement between the predictions and the available experimental data is good.

  • PDF