• Title/Summary/Keyword: 수질정화특성

Search Result 134, Processing Time 0.028 seconds

Performance Enhancement Study of a Final Clarifier by the Optimum Design of Inlet and Baffle Condition (유입구 및 정류벽 최적설계에 의한 최종 침전지 성능 개선 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Jung, Sung-Hee;Gang, Dong-Hyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The effluent quality is directly affected by the separation of biological solids in a final clarifier because the majority of discharged $BOD_5$ and SS are virtually dependent on the results of biological solids in the sedimentation tank effluent. If a final clarifier is effectively designed and operated, the desired goal of clarification for wastewater can be achieved together with the cost reduction in the treatment of wastewater. To this end flow characteristics and the removal efficiency of SS are numerically investigated especially by the change of the inlet position and the installation of baffle to improve the performance of a rectangular final clarifier. The 2-D computer program developed in a rectangular coordinates has been successfully validated against experimental residence time distribution(RTD) curves obtained by tracing radio-isotope. The lowering of the inlet position weakens the density current and induces the settling of SS in the front zone of a clarifier. Thus the decreased traveling distance of the sludge increases the removal efficiency of SS in the effluent. The inlet baffle installed in the front region of clarifier prevents the short circuiting flow and induces to flow into the dense underflow, which eventually improves the effluent quality. In the case of lower inlet position, however, installation of baffle results in degradation of effluent quality. Consequently it is strongly recommended that in-depth numerical study be performed in advance for optimizing a clarifier design and retrofitting to improve effluent quality in a final clarifier.

Construct of uncontaminated underground reservoir test facility (청정지하저수지 시험시설의 구축)

  • Lee, Chang Seob;Park, Nam Sik;Jeong, Jae Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.328-328
    • /
    • 2016
  • 우리나라는 생활용수의 대부분을 지표수에 의존하고 있는 실정이다. 그러나 지표수는 가뭄과 같은 기상변화, 수질사고 등으로 물 공급의 안정성에 문제가 되기도 한다. 향후 기후변화는 가뭄의 빈도와 강도를 증대시킬 것으로 파악되므로 수질 및 수량의 문제를 더욱 악화시킬 것으로 예상된다. 이러한 문제점을 해결하기 위해 지표수를 대수층 내에 인공적으로 함양한 뒤 대수층의 자연정화 기능에 의해 여과된 양질의 청정원수를 생산하는 기술을 본 연구에서 현장에 실증 적용하는 시설을 구축하였다. 이러한 기술은 기존의 지하 대수층을 이용하는 강변여과 등이 갖는 장점을 취하고 단점을 보완하였으며 친환경적이며 지속가능한 용수공급뿐만 아니라 청정 원수 확보를 통해 정수처리비용을 절감, 장기간의 가뭄이나 지표수 수질사고 시에 비상용수 공급 등 기존 취수원들과 달리 많은 장점을 갖고 있는 대규모 청정지하저수지 시험시설이다. 청정 지하저수지 기술이 주로 적용되는 지역은 해안지역 또는 하구 델타지역을 대상으로 한다. 해안 또는 델타지역은 해수침투로 인하여 염지하수가 부존되어 있기 때문에 지하수자원 활용에 매우 제한적이다. 따라서 지표수(담수)를 전처리하여 대수층에 인공적으로 함양을 하여 염지하수 대수층 안에 담지하수(담수체)를 형성할 수 있다. 이는 염수와 담수의 밀도차에 의해 희석되지 않는 특성을 이용한 기술이다. 청정 지하저수지 시험시설은 크게 지표수 취수시설, 전처리시설, 주입정, 양수정, 운영시스템으로 나눌 수 있다. 주입정 및 양수정은 원형의 형태로 지하저수지 조성범위 중심부에 9개의 주입정과 외각에 8개의 양수정을 설치하였다. 시험시설의 운영 과정은 하천수를 취수하여 전처리시설에서 탁도를 제거한 후, 피압대수층 염지하수에 동력으로 주입을 한다. 이때 기존에 부존되어 있던 염지하수를 밀어내고 담수체 지하수 형성을 유도한다. 일정기간 주입을 통해 목표 담수체를 만들어 내면 양수정에서 담수를 취수하되, 대수층의 모래자갈층을 일정거리 이동하여 취수하는 방식이다. 즉, 하천수를 대수층에 함양하고, 일정거리를 이동하여 취수하는 ASTR 방식의 대체수자원 확보 기술이다. 시험시설은 통합운영센터를 통해 원격감시 및 각종 제어/계측을 실시하며, 모니터링된 자료는 운영시스템에서 관리한다. 본 연구시설에서는 대수층 주입, 관정폐색, 미생물/지화학 수질반응, 지하수모니터링, 지반변형 등이 주요 핵심 연구를 진행하고 있도록 시설을 구성하였다. 본 시험시설은 2015년 8월 착공하여 2016년 4월에 완공 예정이며, 2016년 3월부터 주입을 시작하여 6개월간 피압대수층에 주입을 실시하고 이후부터 주입과 양수를 병행할 계획이다.

  • PDF

An Experimental Study on Water-Purification Properties of Porous Concrete Using Industrial By-Products (산업부산물을 사용한 포러스 콘크리트의 수질정화 특성에 관한 실험적 연구)

  • 조영수;김정환;권혁준;박승범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.717-722
    • /
    • 2002
  • The results of an experiment on the water purification of the porous concrete and its influence on the compressive strength are reported in this paper. Two different sizes of coarse aggregate of 5-10, and 10-20mm, and three absolute volume ratios of paste to aggregate of 30, 40 and 50 percent for a given size of aggregate were used. For the compressive strength, the concrete with the aggregate size of 5-10mm showed much higher strength than that with the aggregate size of 10-20mm. But, the compressive strength is higher when the ratio of paste to aggregate is smaller. In the water purification experiment, the amount of attached an organism on the porous concrete surface indirectly is examined by measuring the consumption of the Dissolved Oxygen (DO). The ability of the water purification is evaluated by the removal amount of the Total Phosphorus(T-P) and Total Nitrogen(T-N). The ability of the removal of the T-N and T-P in the test water is superior to a porous concrete with a smaller size of aggregate and a higher void content. These results are owing to a large specific surface area of the specimen. As a result, porous concrete using by-products has sufficient performance of water purification.

  • PDF

Basic Data Analysis on Bio Block Placement for Sea grass Field in the Enclosed Bay (반폐쇄해역에서의 잘피장 조성 바이오블록 거치의 기초자료 분석)

  • Ahn, HyoJae;Lee, JoongWoo;Kang, SeokJin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.183-185
    • /
    • 2015
  • 반폐쇄해역에서는 해수교환이 어렵고 육상에서 유입부하와 적조 등의 영향을 강하게 받기 때문에 항상 수질과 저질이 악화되기 쉬운 환경에 처해 있어서 이의 개선을 위한 일환으로 해양식물(잘피)의 서식환경을 복원하여 해양정화에 기여하기 위한 친환경적 접근이 필요하다. 다양한 해상환경조건하에서 잘피의 서식은 변화므로 특히, 파랑의 극한 외력여건에 견디는 친환경 잘피 지지구조물 기술개발이 우선되어야 한다. 본 연구는 잘피장 조성의 기반기술로 해양식생 지지용 바이오 블록을 개발하고 특히, 관광지 및 해양클러스터 단지로 대외적으로 알려져 있는 영도해역에서 영도구가 야심차게 준비해오고 있는 해상낚시터 인근해역에 적용할 수 있는 바이오 블록의 현장시범거치를 통해 잘피 등 해양식생을 유도하기 기반을 마련하기 위한 기초연구로 대상구역에서의 파랑해석과 식생 조성 후에 파랑의 반응특성을 수치모델을 통해 분석하고자 하였다. 계산 결과는 대상지역에 적용할 사면 피복재로 바이오 블록의 규격을 결정하는데 반영될 것이며 후속 연구에서 실제블록의 제작과 현장거치를 수행하고자 한다.

  • PDF

Strength and Water Purification Characteristics of Effective Microorganism-applied Volcanic Ash Block (유용미생물을 적용한 화산재 블록의 강도 및 수질정화 특성)

  • Lee, Chung-Won;Chang, Dong-Su;Park, Sung-Yong;Choi, Joong-Dae;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • The aim of this study is to investigate strength and water purification characteristics of effective microorganism-applied volcanic ash block using flexural strength test and water quality analysis. The specimens were prepared with volcanic ash from Mt. Baekdusan and Mt. Hallasan, and cement as the ratios of 3.5:1, 4.0:1, 4.5:1, 5.0:1 with and without metakaolin. Flexural strength degraded with increasing of the amount of volcanic ash, and increased with addition of metakaolin as a binder. Based on these results, the optimal ratio for fabricating volcanic ash-cement mixture block is determined as 3.5:1 with metakaolin. Furthermore, from water quality analysis on contaminated water, removal ability of effective microorganism-applied volcanic ash-cement mixture block and caged volcanic ash block against T-N, T-P and SS was highly evaluated because of adsorption due to the large specific surface area of volcanic ash. Hence, volcanic ash-cement mixture block and caged volcanic ash block possibly contribute to water purification.

Vegetation and Water Purification Characteristics of Lapilli-Bio Block (화산력-바이오 블록의 식생 및 수질정화 특성)

  • Park, Sungyong;Nam, Boohyun;Kim, Jungmeyon;Choi, KiBong;Yeon, Kyuseok;Kim, Yongseong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.6
    • /
    • pp.47-54
    • /
    • 2016
  • This study is a basic research on the functional performance review for the use of environmentally friendly construction materials as lapilli-bio block. The neutralization processed Mt. Backdusan and Mt. Hallasan lapilli-bio block were identified vegetation characteristics and water purification properties. As a result, the adsorption of root was more favorable, depending on the material properties of many voids Lapilli. And if the neutralization processed lapilli-bio blocks maintain a long-term immersion conditions in contaminated water was found to be expected from the improvement effect of SS, T-N and T-P. However, field trials and continuous studies are expected to be identified by the use of lapilli-bio block.

Adsorption Characteristics of Altered Feldspar Porphyry for Heavy Metals (변질 장석반암의 중금속 흡착특성)

  • Park, Sang-Bum;Hwang, Jeong
    • Journal of the Korean earth science society
    • /
    • v.29 no.3
    • /
    • pp.246-254
    • /
    • 2008
  • This study has been performed to evaluate the possibility of utilizing feldspar porphyry as an adsorbent for heavy metals in natural water. The research sample rock 'Maekbansuk' was altered feldspar porphyry which included chlorite, epidote and calcite formed by a prophylitic alteration process. In extraction tests, the majority of extracted elements were Ca and Na, which were extracted in much greater abundance from the groundmass than from the feldspar phenocryst. In adsorption tests, the adsorption capacities of Pb, Fe and Cu within an hour of reaction time were 99, 98 and 97%, respectively, but that of As remained 25% for a full 24 hours. The high adsorption capacities of altered feldspar porphyry for Pb, Fe and Cu suggest its potential utilization as a heavy metal adsorbent fur water purification.

Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer (레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구)

  • Lim, Yun Gyu;Yang, Hae Jeong;Kim, Yung Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Heavy Metal Contamination and the Roles of Retention Pond and Hydrologic Mixing for Removal of Heavy Metals in Mine Drainage, Kwangyang Au-Ag Mine Area (광양 폐 금-은 광산 지역 광산폐수의 중금속 오염과 중금속의 제거에 있어 소택지와 지류 혼합의 역할 평가)

  • 정헌복;윤성택;김순오;소칠섭;정명채
    • The Journal of Engineering Geology
    • /
    • v.13 no.1
    • /
    • pp.29-50
    • /
    • 2003
  • Physicochemical Properties of acid mine water of the Chonam-ri Creek and the Sagok-ri Creek in the Kwangyang Au-Ag mine area were determined using geochemical approaches. Metal contamination (Cd, Cu, Pb, Zn) is more serious in the Chonam-ri Creek than in the Sagok-ri Creek. However, the contents of Al and Fe is higher in the Sagok-ri Creek. Such differences between the two creeks probably reflect the abundance and composition of ore minerals. The attenuation processes for acid mine water in both creeks were investigated. In the Chonam-ri Creek, a small retention pond which contains limestone plays an important role in the removal of heavy metals by adsorption or coprecipitation due to increase of pH. The capacity of metal scavenging in this pond depends on the seasonal variation of inflow volume. Reddish yellow precipitates sampled in the Chonam-ri Creek were analyzed by XRD, SEM-EDS, EPMA, and chemical decomposition. The precipitates mainly consist of goethite and are also enriched in Al, Mn, Cu and Zn. This inditates that precipitation of goethite is important for scavenging those trace elements, possibly due to adsorption or coprecipitation. In the Sagok-ri Creek, on the other hand, hydrologic mixing of uncontaminated tributaries results in removal of heavy metals with iron hydroxides precipitation due to the pH increase. The mechanisms proposed for metal attenuation at the confluence between contaminated mine water and uncontaminated tributary water are also explained by the property-property plots.

A Study on the Applicability of Soilremediation Technology for Contaminated Sediment in Agro-livestock Reservoir (농축산저수지 오염퇴적토의 토양정화기술에 대한 적용성 연구)

  • Jung, Jaeyun;Chang, Yoonyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.3
    • /
    • pp.157-181
    • /
    • 2020
  • Sediments from rivers, lakes and marine ports serve as end points for pollutants discharged into the water, and at the same time serve as sources of pollutants that are continuously released into the water. Until now, the contaminated sediments have been landfilled or dumped at sea. Landfilling, however, was expensive and dumping at sea was completely banned due to the London Convention. Therefore, this study applied contaminated sedimentation soil of 'Royal Palace Livestock Complex' as soil purification method. Soil remediation methods were applied to pretreatment, composting, soil washing, electrokinetics, and thermal desorption by selecting overseas application cases and domestically applicable application technologies. As a result of surveying the site for pollutant characteristics, Disolved Oxigen (DO), Suspended Solid (SS), Chemical Oxygen Demand (COD), Total Nitrogen (TN), and Total Phosphorus (TP) exceeded the discharged water quality standard, and especially SS, COD, TN, and TP exceeded the standard several tens to several hundred times. Soil showed high concentrations of copper and zinc, which promote the growth of pig feed, and cadmium exceeded 1 standard of Soil Environment Conservation Act. In the pretreatment technology, hydrocyclone was used for particle size separation, and the fine soil was separated by more than 80%. Composting was performed on organic and Total Petroleum Hydrocarbon (TPH) contaminated soils. TPH was treated within the standard of concern, and E. coli was analyzed to be high in organic matter, and the fertilizer specification was satisfied by applying the optimum composting conditions at 70℃, but the organic matter content was lower than the fertilizer specification. As a result of continuous washing test, Cd has 5 levels of residual material in fine soil. Cu and Zn were mostly composed of ion exchange properties (stage 1), carbonates (stage 2), and iron / manganese oxides (stage 3), which facilitate easy separation of contamination. As a result of applying acid dissolution and multi-stage washing step by step, hydrochloric acid, 1.0M, 1: 3, 200rpm, 60min was analyzed as the optimal washing factor. Most of the contaminated sediments were found to satisfy the Soil Environmental Conservation Act's standards. Therefore, as a result of the applicability test of this study, soil with high heavy metal contamination was used as aggregate by applying soil cleaning after pre-treatment. It was possible to verify that it was efficient to use organic and oil-contaminated soil as compost Maturity after exterminating contaminants and E. coli by applying composting.