• Title/Summary/Keyword: 수질감시

Search Result 125, Processing Time 0.03 seconds

Study on Improving Reliability of Biomonitor by Using CCD Camera (CCD카메라를 이용한 생물감시장치의 독성자료 신뢰성 향상에 관한 연구)

  • Kim, Hyun-Chang;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1351-1357
    • /
    • 2010
  • Water monitoring equipments using daphnia can be used to monitor the pollution levels of a country's main rivers. Such equipments should be capable of providing a prompt warning about increase in the contamination levels, which is evaluated on the basis of impulse number or toxicity index. As unmanned remote control equipments, they must provide reliable pollution monitoring results for each season and for the annual physical changes in each river. Two different equipments based on the impulse number and toxicity index showed different results for the operating rates and for the number of emergency checks required even though both were operated at the same conditions. The results are affected by many parameters such as the presence of any air bubbles and the microscopic pressure. The purpose of this study is to develop a method that can reduce the effect of bubbles or microscopic pressure on the monitoring data. We expect to achieve reliable monitoring data for water pollutants irrespective of the location of the equipment setup.

Trends of Groundwater Quality in the Areas with a High Possibility of Pollution (국내 오염우려지역의 지하수 수질 추세 특성)

  • Kim, Gyoobum;Choi, Doohoung;Yoon, Pilsun;Kim, Kiyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.5-16
    • /
    • 2010
  • Groundwater quality monitoring wells, which is over 2,000 in South Korea, were managed to observe groundwater quality since the early 1990s. Groundwater was sampled and analyzed biannually from 781 monitoring wells located in the areas with a high possibility of pollution. The average concentrations of cyanide, mercury, phenols, hexavalent chromium, trichloroethylene, tetrachloroethylen, and 1.1.1-trichloroethane for 12 years' data of detected cases were above the groundwater quality standard, but the average concentrations of the general quality items such as pH, electric conductivity, nitrate-nitrogen, and chloride, are below the standard. To compare a quality trend for each land-use type of the monitoring site, Sen's method is used for four quality items; chloride, nitrate-nitrogen, pH, and electric conductivity. The upward trend for these items is remarkable in urbideareas and industrial complexes and this trend continues still strongly after 2001. The deviation in a trend slopes of monitoring wells becomes bigger in the mid-2000s. In conclusion, trend analysis using existing monitoring data cidebe effective to forecast the future water quality condition and the solid action to protect groundwater quality should be done in advance using a result of trend analysis.

On-line identification of the toxicological substance in the water system using Baysian technique (베이지언 기법을 이용한 수계 내의 독성물질 판단)

  • Jung, Ha-Kyu;Jung, Jong-Hyuk;Lee, Hyun-Wook;Kwon, Won-Tae;Kim, Sang-Gil;Jeon, Sook-Lye
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3122-3127
    • /
    • 2007
  • Water resource can be examined using biological sensors. Algae has been one of the biological sensors used to evaluate and monitor the water pollution. The monitoring system, however, could determine whether the examined water was safe or not. It needs additional expensive chemical test to figure out the cause of the water pollution. In this study, an endeavor is given to identify the toxicant in the water using the shape of the chlorophyll fluorescence induction curve(FIC) from algae using monitoring system. Fundamental curves are obtained from the experiments with specified amount of toxicant. Baysian method is utilized to determine the unknown toxicant in the water by comparing it with the fundamental curves. The results shows that the proposed method works fairly well.

  • PDF

On-line identification of the toxicological substance in the water system using Baysian technique (베이지언 기법을 이용한 수계 내의 독성물질 판단)

  • Jung, Ha Kyu;Jung, Jong Hyuk;Lee, Hyun Wook;Kwon, Won Tae;Kim, Sang Gil;Jeon, Sook Lye
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.73-78
    • /
    • 2008
  • Water resource can be examined using biological sensors. Algae has been one of the biological sensors used to evaluate and to monitor the water pollution. The monitoring system, however, has not been used to determine what kind of the toxicological substance is in the water. It needs additional expensive chemical test to figure out the cause of the water pollution. In this study, an endeavor is made to identify the toxicant in the water using the shape of the chlorophyll fluorescence induction curve(FIC) from algae using monitoring system. Fundamental curves are obtained from the experiments with specified amount of toxicant. Baysian method is utilized to determine the unknown toxicant in the water by comparing it with the fundamental curves. The results shows that the proposed method works fairly well.

A Study for drone and robot to monitor, sterilize and clean the air/water/soil pollution of smart livestock (스마트 축사의 공기/수질/토양 오염을 감시, 살균 및 청소할 드론과 로봇에 관한 연구)

  • Kim, Do-Yeup;Jung, Chan-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.737-739
    • /
    • 2022
  • 본 논문은 스마트 축사의 공기/수질/토양 오염을 감시, 살균 및 청소할 드론과 로봇에 관한 연구이다. 서론에서는 서귀포시에서 최근에 개발되어 보급을 시작한 스마트 축사 시스템의 시범서비스와 바른전자의 사례를 통해서 시스템의 발전 방향과 문제점들을 분석한다. 본론에서는 차세대 스마트 축사의 전체 구성도와 서비스 구성표를 작성함으로써 연구개발의 방향을 모색하고, 인공지능, 빅데이터 분석, 드론, 로봇의 협동 방식의 스마트 축사를 구상하여 현존하는 스마트 축사 시스템의 문제점들을 보완하였다. 결론적으로, 본 논문은 차세대 스마트 축사의 환경오염과 자연생태계위협을 근원적으로 해결할 입체적인 감지정보처리 및 실시간으로 오염/전염병의 예방과 선제적 대응을 포함한, 축사에서 발생할 오염 및 전염병 사고/사건을 관할 당국에 신고하고 행정명령을 처리하는 ICT기반시설을 제안한다.

Hydrogeological Site Monitoring in Low and Intermediate Level Radioactive Waste Disposal Facilities (중·저준위 방사성 폐기물 처분시설의 부지 감시 현황)

  • Chung-Mo Lee;Soon Il OK;Seongyeon Jung;Sieun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.17-17
    • /
    • 2023
  • 국내의 부지특성 및 감시 관련 규정은 원자력 안전위원회 고시 제2021-16호 제4조(세부지침)와 원자력 안전위원회 고시 제2021-17호 제16조에 의거하고, 국외는 국제원자력기구(IAEA: International Atomic Energy Agency)에서 안전기준을 제시하고 있다(IAEA, 2011). 따라서 국내 중·저준위 방사성폐기물 처분시설은 2006년부터 광역 지질을 포함한 부지 지질/지형, 기상, 수문, 수리지질, 인문사회 등을 망라한 조사를 시행하여 부지 현황에 대한 분석 및 안정성 평가를 수행한다. 부지감시의 수문·지구화학 분야에서는 현장 수질 측정 6항목과 실내 분석 26항목을 감시하고 있으나, 본 연구는 이 중 9개 항목(EC, Na, K, Ca, Mg, SiO2, Cl, SO4, HCO3)을 선정하여 분석하였다. 연구 목적은 물시료 분석자료의 주성분-다중선형회귀-군집 분석과 Piper Diagram 분석결과로부터 해수와 담수(지하수)와의 특성분석 및 해수 영향을 분석하는 것이다. 현장 부지내 지하수 7개 관정(GM-1, 2, 4, 5, 6, 7, 8)과 해수 2개 지점(Sea-1, 2)을 대상으로 통계학적 주성분 분석결과, 대부분의 지하수는2개~4개의 요인으로 구분되고, 해수와의 유사성을 해석하기 위해 확인한 관정은 GM-5, GM-6, GM-1 지점으로 분류되었다. 상기와 같이 해수의 영향을 확인하기 위해 해수 2개 지점과 동일한 군집으로 분류되는 지하수는 GM-5 관정으로 확인되었고, 해안선에서 가까운 GM-5 관정과 같이 유사한 거리에 분포한 지하수 GM-1, 2, 4 관정은 2개 혹은 3개의 최적 군집으로 분류하였을 때도 GM-5와는 다른 특성을 보여주었다. 이는 해안과 인접하더라도 수질은 다른 지질학적 특성(지형, 기상, 단열대 등)에 따라 영향받았음을 지시한다.

  • PDF

Detection of turbid water generated pipe through back tracing calculation method in water distribution system (상수관망에서 역추적 계산법을 이용한 탁수 발생관 탐지)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi;Han, Jin Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.482-482
    • /
    • 2023
  • 상수도관은 사용년수가 경과함에 따라 노후화가 진행되며, 노후화된 상수관은 내부적으로 부식, 이물질 퇴적, 균열 등의 현상이 발생하게 되고, 이는 결국 수질문제로 연결되어, 탁수사고 발생 확률증가의 주요 원인이 되고 있다. 국내 상수도관의 경우 매설년수의 증가로 인해 내구연한이 도래한 상수관망의 비중이 점차 증가하고 있으며, 2019년 서울시 문래동 수질사고, 2019년 인천 붉은 수돗물 사고, 2022년 안양 동안구 탁수사고, 2022년 여수시 웅천 탁수사고 등 관의 노후화로인한 탁수 사고가 빈번하게 발생되고 있어 수도 사용자에게 불편함을 끼치고 있다. 현재 정수장 및 상수관망에 설치된 탁도계를 통해 수질에 대한 감시를 진행하고 있지만, 경제적인 문제로 인해 모든 상수도관에 탁도계를 설치하기에는 현실적으로 불가능하며, 제한적인 탁도계의 개수를 통해 수질에 대한 감시 및 관리를 진행하고 있는 실정이다. 이러한 상황으로 인해 탁수사고 발생 시 발생 원인분석 및 최초 발생위치 결정이 쉽지 않으며, 보수 보강을 통한 상수도관의 정상화까지 오랜 시간이 걸리게 된다. 이에 본 연구에서는 상수관망에서 탁수 발생 시 최초 발생 위치를 결정할 수 있는 기법을 개발하였으며, 이를 실제 상수도관망에 적용하여 탁수발생 파이프를 탐지하였다. 탁수사고 발생 시 실측된 수질 데이터의 부족으로 인해 임의의 파이프에서 탁수가 발생하였다고 가상의 탁수 발생시나리오를 가정하였으며, 완전혼합농도식을 통해 관망에 설치된 탁도계의 NTU(Nethelometric Paultity Unit) 농도를 계산하여 가상의 탁수발생 시나리오를 상수도관망에 적용하였다. 이후, 역추적 계산기법을 통해 파이프의 초기 NTU 농도를 변화시켜주며 관망내 설치된 탁도계의 NTU 농도를 계산하였으며, 가상 시나리오를 적용하여 계산된 탁도계의 NTU 농도와 역추적 계산법을 적용하여 계산된 탁도계의 NTU 농도의 Percentage Error를 비교/분석하여 탁수 발생 파이프를 탐지하였다. 분석결과, 가상 시나리오의 최초 탁수발생 파이프와 역추적 계산법을 적용하여 탐지한 최초 탁수발생 파이프의 위치가 일치하는 것으로 나타났다. 본 연구에서 개발된 역추적계산을 통한 탁수발생 파이프 탐지기법을 실제 관로 교체사업에 활용한다면 파이프의 개선 우선순위를 보다 명확하게 판단할 수 있으며, 더 나아가 상수도 관망의 유지관리에 활용하여 경제적이고 효율적인 상수관망 시스템관리를 할 수 있을 것으로 판단된다.

  • PDF