• Title/Summary/Keyword: 수직 및 경사말뚝

Search Result 5, Processing Time 0.02 seconds

Shear Tests Under Constant Normal Stiffness for Granite-concrete Interface (화강암 절단면과 콘크리트 부착면에 대한 일정강성도 전단시험)

  • 조천환;이명환;유한규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.5-12
    • /
    • 2004
  • The purpose of this paper is to make an understanding of fundamental mechanism of shear behaviour between rock and concrete interfaces in the pile socketed into granite. The interface of pile socketed in rock can be modeled in laboratory tests by resolving the axi-symmetric pile situation into the two dimensional situation under CNS(constant normal stiffness) direct shear condition. In this paper, the granite core samples were used to simulate the interface condition of piles socketed in granite in our country. The samples were prepared in the laboratory to simulate field condition, roughness(angle and height), stress boundary condition, and then tested by CNS direct shear tests. This paper describes shearing behaviour of socket piles into domestic granite through the analysis of CNS test results. It was found out that the peak shear strength increases with the angle of asperity and CNS value, and also the dilation increases with the angle of asperity but decreases with the CNS value.

Influence of the Anchor Slope on Behaviour of Sheet Pile (앵커의 경사(傾斜)가 널말뚝의 거동(擧動)에 미치는 영향(影響))

  • Chun, Byung Sik;Kang, In Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.79-87
    • /
    • 1989
  • The influence of anchor slope on behavior of sheet pile is analysed by results of model test. It can be seen that the larger inclination of anchor causes more causes more increases of the horizontal and vertical deflection of wall, but the bending moment is less influenced by the inclination of anchor. The negative friction against vertical settlement of wall has the yielding point at the excavation level of 0.71-0.80 H. The redistribution of earth pressure on the sheet pile with dredging must be considered by soil-arching. The zero pressure point from the toe of wall is 20% higher than that of the Free Earth Support Method. It is also observed that the angle of failure planes to major principal plane is larger than the angle of $45^{\circ}+{\phi}/2$.

  • PDF

Experimental Behavior Characteristics of 2×2 Group Pile under Lateral Loads (수평하중을 받는 2×2 무리말뚝의 실험적 거동 특성)

  • Kwon, Oh-Kyun;Park, Jong-Un
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.5-16
    • /
    • 2018
  • In this study, the large scale laboratory model tests were executed to investigate the lateral resistance characteristics of $2{\times}2$ group pile under lateral loads according to the array method and installation angle of piles. The effect on the behavior of $2{\times}2$ group pile was also investigated through model tests varying the pile diameter and length, distance to pile top from the ground surface, center-to-center (CTC) length and surcharge etc. From these test results, it was found that the lateral resistance of $2{\times}2$ group pile of which piles were constructed slantly in both directions was greater than that of group pile of which piles were constructed vertically. And as a result of parameter tests on the lateral resistance of $2{\times}2$ group pile, it was found that the most important parameter was the pile length. As the embedment depth ratio (L/D) increased to 36.5 from 26.5, the lateral resistance increased 3~4 times or more. But the center-to-center (CTC) length, distance to pile top from the ground surface and surcharge did not affect much on the lateral resistance of group pile.

Horizontal Behavior Characteristics of Umbrella-Type Micropile Applied in Sandy Soil Subjected to Seismic Motion (사질토 지반에 설치된 우산형 마이크로파일의 지진 시 수평거동 특성)

  • Kim, Soo-Bong;Son, Su Won;Kim, Jin Man
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.7
    • /
    • pp.5-16
    • /
    • 2020
  • Currently, the seismic design standards have been strengthened due to the occurrence of the Gyeongju and Pohang earthquake, and seismic performance evaluation of existing facilities is being conducted. It aims to secure a seismic performance effect during earthquakes by improving the micro-pile method, which can be constructed in limited confined places while minimizing damage to existing facilities. The improvement method is to construct all the piles in the square-tray-type plate on the top of the pile by constructing the slope pile in the form of an umbrella around the vertical pile, the main pillar. In this paper, the numerical analysis was performed to analyze the horizontal displacement behavior of an umbrella-type micropile for various real-measurement seismic waves in sandy soil. As a result of numerical analysis, the softer the ground, the better the effect of horizontal resistance of umbrella-type micropile. The horizontal displacement reduction effect was pronounced when the embedded depth was 15 m or more at the same ground strength, and it was found to be effective in earthquakes if it was settled on the ground with an N value of 30 or more. The embedded depth and horizontal displacement suppression effect of the micropile was proportional. Generally, the weaker the ground, the greater the displacement suppression effect. Umbrella-type micropile had a composite resistance effect in which the vertical pile resists the moment and inclined pile resists the axial force.

The Experimental Study of Distribution Life-Force Impact on Piles and Landing Pier (잔교식 안벽의 상부와 Pile에 작용하는 파압분포에 관한 실험적 연구)

  • Park, Sang-Kil;Kim, Ki-Hyun;Kim, Woo-Seang;Park, Byung-Yul;Kang, Deok-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.552-556
    • /
    • 2006
  • 항만건설에 있어서 항만의 내부시설 중에서 무엇보다도 가장 중요한 시설물은 선박을 안전하게 접안시켜 하역할 수 있는 안벽시설물이다. 안벽구조 형식의 결정은 항만의 이용목적 등에 따라서 달라지지만 항만의 건설입지조건 등에 의해서도 달라진다. 안벽구조형식 중에서 잔교 식 안벽은 무엇보다도 단기간에 건설이 용이하여 지금까지 각국에서 널리 사용되어 왔고 장래에도 이용도가 증가되리라 생각한다. 최근에는 해안선을 이용한 위락시설이 건설되면서 잔교 식 안벽구조물을 설치하여 보조시설물로 이용하는 경우가 많다. 과거에 설계되어 잔교를 설계할 경우는 일반적으로 항내의 정온이 잘 유지되는 경우에 대해서 설치하는 경우가 많기 때문에 파랑에 의한 반사율과 잔교 상부에 작용하는 양압력을 고려해야할 필요성이 거의 없었다. 그러나 최근에는 태풍이 내습할 경우 기존의 항내로 높은 파랑이 침입하는 경우가 발생하고 있어 항내에서도 잔교의 파괴로 인한 자연재해가 대형화되는 경우가 발생하고 있다. 또, 처음부터 안벽을 설계할 때에 대형화의 잔교 식 안벽구조물을 설치하는 경우도 있다. 이런 잔교 식 안벽 구조물을 잔교의 상부 판에 작용하는 양압력 분포와 잔교 전면의 반사율 등이 구조물의 유지관리 등에 미치는 영향이 매우 크기 때문에 반사율 검토와 양압력을 고려한 설계가 필요하다. 본연구의 대상은 일정 해역에 잔교 식 안벽을 설계하고자 할때 최적의 안벽 설계가 될 수 있도록 수리모형실험을 실시하여 구조물의 안전과 항내정온에 기초가 되는 자료를 도출하고자 하였다. 따라서 본 수리모형실험으로 인한 연구는 잔교 식 안벽에 대한 반사율과 상부에 작용하는 양압력, 잔교말뚝(pile)에 작용하는 수평압력을 검토하여 잔교 식 안벽 설계에 기초자료를 제공하고자 한다. 혈청을 이용한 동결보존을 대체할 수 있을 것으로 생각된다.지에 더해주면 세포의 증식이 개선될 것이다. 그래서 몇 가지 첨가물을 이용해 세포의 증식력에 변화가 나타나는지 알아보았다. 첨가물을 이용한 실험에서 IGF-I의 경우 장기간 배양에서 세포의 수를 안정적으로 유지하고 계대 횟수를 증가시키는 효과를 보였다. 이는 IGF-I이 어느정도 세포의 증식을 유지시켜주는 역할을 하기 때문인 것으로 생각된다. 무혈청 배지에서 비적응 CHO 세포의 계대 배양에 한계가 있는 것은 세포주기가 멈추기 때문인 것으로 생각된다. 세포주기가 멈추는 growth factor와 같이 세포의 증식을 지속적으로 유도할 수 있는 물질이 무혈청 배지에서는 부족하기 때문인 것으로 생각되고, IGF-I과 같은 첨가물을 통해 극복할 수 있는 문제라고 여겨진다.관점과 주거교육가치관 요소와의 관계를 알아본 결과, 전통적 관점은 주거교육가치관 요소 중 오직 주거관리적 요소와 관계가 있었으나 그 정도는 낮으며 실천적 관점과 구조적 관점은 주거가치관의 각 요소에 따라 약간 다르기는 했으나 주로 보통의 관계를 보였다.군 순으로 높게 관찰되었다. 이상의 결과를 종합할 때, 임상에서 니켈-티타늄 합금 와이어에 굴곡을 부여하기 위해 열처리하는 경우 초탄성 특성은 유지될 수 있으나, 부하-변위 곡선의 상방 증가가 나타나므로, 와이어에 의한 교정력이 증가될 수 있음에 유의하여야 한다. $day^{-1}$인 인공습지), scenario 2(면적 4.2ha인 저류지)가 각각 연평균 6.9%, 4.8%, 7.1%의 감소를 보였다. TN은 4.7%, 3.4%, 13.4%의 삭감율을 나타내었으며, TP는 5.6%, 3.9%, 7.3%의 삭감율을 나타내었다. 본 연구에서는