수직밀폐형 지중열교환기의 최적설계를 위한 설계인자 영향도 분석 (Sensitivity Analysis on Design Factor of Ground Heat Exchanger for Optimum Design of Vertical Ground Source Heat Pump System)

  • 배상무;김홍교;남유진
    • 대한건축학회논문집:구조계
    • /
    • 제34권3호
    • /
    • pp.87-93
    • /
    • 2018
  • Ground source heat pump(GSHP) system is one of the high efficiency heat source systems which utilizes the constant geothermal energy of a underground water or soil. However, the design of conventional GSHP system in the domestic market is dependent on the experience of the designer and the installer, and it causes increase of initial installation cost or degradation of system performance. Therefore, it is necessary to develop a guideline and the optimal design method to maintain stable performance of the system and reduce installation cost. In this study, in order to optimize the GSHP system, design factors according to ground heat exchanger(GHX) type have been examine by simulation tool. Furthermore, the design factors and the correlation of a single U-tube and a double U-tube were analyzed quantitatively through sensitivity analysis. Results indicated that, the length of the ground heat exchanger was greatly influenced by grout thermal conductivity for single U-tube and pipe spacing for double U-tube.

지하수 과다유입 조건하에서의 터널굴착 (Tunneling in Severe Groundwater Inflow Condition)

  • 이용남;김대영
    • 한국지반환경공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.67-76
    • /
    • 2006
  • 본 논문은 수직 절리가 잘 발달된 지하수위가 높은 화산암질 지반에서 직경 3.3m의 도수터널 굴착을 하는 수력발전소 건설공사 내용이다. 취수시설은 발전소로부터 20.3km 상류에 위치하고 있으며, 20km의 도수터널과 연결되어 있고 440m의 낙차고를 갖는 펜스탁이 발전소와 연결되어 있다. 현장의 지질 조건은 전형적인 칼데라 호수인 토바호에 의해 지반 침식과 수직방향의 인장균열이 발달하였으며 이로 인해 지반의 초기응력이 이완되었다. 높은 지하수위(최대 수두 200m)를 가진 잘 발달된 수직 절리를 터널이 관통하면서 막대한 양의 지하수가 터널내로 유입되었다. 터널 굴착은 개방형 쉴드 TBM과 버럭반출에는 철로와 기관차를 사용하였다. 터널 내로의 유입수가 터널 바닥면에서 70cm 높이에 다다르고 이는 터널 직경(3.9m)의 17%에 해당하였다. 생산성을 향상하기 위해서 TBM과 버럭반출 차량과 같은 몇 가지의 개선과 수중펌프를 증설하는 방안을 사용하였다. 굴착 중에 만난 지반 조건이 설계보다 상당히 불량하여 RC라이닝에서 지하수 유입, 암반조건, 수압 등에 따라 PC 세그먼트 라이닝 또는 PC 세그먼트 라이닝과 현장타설 RC 라이닝, RC 라이닝, 그리고 강재 라이닝이 적용되었다. 이 PC 세그먼트 라이닝의 도입과 TBM과 다른 장비의 개조 및 개선을 통해서 심각한 지하수 조건 하에서 터널 굴착 공사를 성공적으로 완료하였다.

  • PDF

시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석 (Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture)

  • 유영선;강연구;강금춘;김영중;백이
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.90-95
    • /
    • 2008
  • 수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 $240m^2$ 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 $40^{\circ}C$에서 $58^{\circ}C$로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 $25.5^{\circ}C$에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 $33.5^{\circ}C$에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 $14.3^{\circ}C$가 상승하였으며 150cm는 $15.3^{\circ}C$가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 $4.3^{\circ}C$의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 $7.5^{\circ}C$의 온포가 하강하였으며, 토양온도가 평균 $27.5^{\circ}C$ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 $4.2^{\circ}C$ 상승하였다. 축열조내 열전달매체유의 온도가 $26.0^{\circ}C$에서 $2.0^{\circ}C$까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 $2.0^{\circ}C$까지 냉열을 축열한 후 $25.4^{\circ}C$까지 방열되는 시간은 외기온이 평균 $28.5^{\circ}C$일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.

지중 열교환기의 보어홀 열저항 산정에 관한 연구 (Evaluation of Borehole Thermal Resistance in Ground Heat Exchanger)

  • 윤석;이승래;강한별;고규현;김민준;신호성
    • 한국지반공학회논문집
    • /
    • 제29권10호
    • /
    • pp.49-56
    • /
    • 2013
  • 최근 들어 경제적이고 친환경적인 에너지 활용을 위하여 지열에너지 필요성이 증대되고 있다. 지반의 열전도도(ground thermal conductivity)와 보어홀 열저항(borehole thermal resistance)은 지열 히트펌프 시스템(geothermal heat pump system)의 설계 과정에서 매우 중요한 변수이다. 본 논문에서는 일반 수직밀폐형에서의 U, W 타입의 지중 열교환기(ground heat exchanger)를 매립지 지반에 설치한 후 100시간 연속 운전 조건으로 현장 열성능 실험(thermal performance test)을 수행하였다. 또한 보어홀 열저항 산정 모델들을 이용하여 열효율을 산정한 후 이를 실험값과 비교하였다. 실험 결과 기존에 주로 적용되고 있는 shape factor(SF) 모델보다 multi-pole과 equivalent diameter(EQD) 모델이 계측값과 잘 일치하였다.

현지 측정에 의한 남한지역의 지중유효열전도도, 보어홀 전열저항 및 초기온도 분석 (Analysis of Soil Thermal Conductivities, Borehole Thermal Resistances and Initial Soil Temperature with In-Situ Testing in South Korea)

  • 노정근;연광석;송헌
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.68-74
    • /
    • 2012
  • Investigation of the effective soil thermal conductivity($k$) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. The first step is measured for initial soil temperature. This is done by supplying a only pump power into a borehole heat exchanger. They need to supply into water unload heat power more than 30 minutes. In this study, the initial soil temperature was found to analysis $14.1{\sim}16.0^{\circ}C$,the ratio was 68.7% represented. In this case of $k$, was 2.1~3.0 $W/m{\cdot}k$, $R_b$ was 0.11~0.20 $m{\cdot}K/W$. In this work, it is also shown that the distribution of a soil thermal conductivity and borehole thermal resistance were on the influence of initial soil temperature. And soil thermal conductivity was related with factors of equation by linear least square method, borehole thermal resistance was on the influence of composite factors.

선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation)

  • 노정근;연광석;송헌
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.

가습 주기에 따른 벽면형 식물바이오필터의 토양 수분 안정화 및 실내공기질 정화 (Stabilizing Soil Moisture and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System Controlled by Humidifying Cycle)

  • 이창희;최봄;천만영
    • 원예과학기술지
    • /
    • 제33권4호
    • /
    • pp.605-617
    • /
    • 2015
  • 본 연구의 최종 목표는 실내의 공간과 식물바이오필터의 규모에 따라 실내공기 오염물질을 정화할 수 있는 식물 녹화와 자동관수 그리고 생물학적 여과 기능을 통합한 식물바이오필터 시스템의 개발이다. 본 연구는 가습 주기에 따른 벽면형(수직형) 식물바이오필터내 공기 흐름의 특성에 대한 안정성과 미세먼지 제거율을 비교하고, 이 식물바이오필터에 의한 휘발성 유기화합물의 제거율을 조사하기 위해 수행하였다. 본 실험에 사용된 식물바이오필터는 실내 공간 활용에 적합하도록 물펌프, 물탱크, 송풍기, 가습장치, 그리고 다층구조의 식물 식재 공간을 일체형으로 설계하였다. 실험 결과, 물펌프에 의해 작동하는 세 가지 다른 가습 주기 처리에 관계없이 식물바이오필터의 상대습도, 온도, 그리고 토양 수분 함량은 안정된 값을 나타내었다. 토양 수분 함량은 모든 가습 주기 처리에서 27.1-29.7%의 범위에서 안정적으로 유지하였으며, 특히 15분 작동 45분 작동 중지의 가습 주기를 120시간 동안 처리하여 $29.0{\pm}0.2%$의 평균 토양 수분 함량을 유지하면서 가장 수평적인 일차회귀식(y = 0.0008x + 29.09)을 보여주었다. 가습 주기에 따라 식물바이오필터를 통과한 미세먼지(PM10)와 초미세먼지(PM2.5) 입자 수에 대한 제거율(RE)은 각각 82.7-89.7%와 65.4-73.0% 범위에 있었고, PM10의 무게에 대한 RE는 58.1-78.9%의 범위에 있었다. 식물바이오필터를 통과한 자일렌, 에틸벤젠, 총 휘발성 유기화합물, 톨루엔의 RE는 71.3-75.5%의 범위에 있었으나, 벤젠과 포름알데히드의 RE는 각각 39.7%와 44.9%로 나타났다. 따라서 실내식물을 식재할 수 있는 본 벽면형 식물바이오필터는 실내 공기 정화에 매우 효과가 있는 것으로 확인하였다.

펠렛형 폐기물 고형연료의 저장 특성 연구 (The storage characteristic study of pelletized RDF)

  • 최연석;김영재;한소영;정민홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.157-157
    • /
    • 2010
  • RDF는 장기저장이 가능한 것이 특징 중의 하나이지만, 우리나라보다 앞서 대량저장을 시작한 일본의 RDF 저장 사일로에서 폭발사고가 발생한 사례가 있어, RDF를 실제로 저장하여 RDF 온도 및 가연성가스 발생상황 등을 장기간 감시 측정하여 사일로 안전관리지표를 도출하였다. 실험에 사용한 RDF 저장조는 직경 3.1m, 높이 11.4m의 사일로방식으로 제작하였다. RDF 저장량은 $70m^3$이었으며, 저장기간은 475일이었다. 사일로에는 15개의 열전대를 설치하여 사일로 표면, 직경방향 1.2m 지점 및 기온을 측정하여 수직방향 및 수평방향의 온도변화를 분석하였다. 가스 샘플링포트는 온도측정지점과 동일한 위치 설치하여 진공펌프로 흡인하여 테트라 백에 포집하여 GC로 분석하였으며, 가스샘플링은 17회 실시하였다. 비교적 대형 저장설비이고 RDF가 열전도성이 낮은 물질임에도 불구하고 사일로 내부온도는 기온보다는 높았지만, 기온의 영향을 많이 받아 7월에 정점, 1월에 하점을 나타내는 사인곡선과 같은 패턴을 보였다. 측정지점별 온도차는 수평방향 보다 수직방향에서 높게 나타났으며, RDF층으로 전열 및 축열이 진행되고 생화학반응을 촉진시키는 상승작용의 결과로 월평균온도가 $49^{\circ}C$를 나타내는 지점도 있었다. 실제 사일로는 RDF의 투입과 배출이 연속적으로 진행되어 방열이 이루어지므로 하계에 대량저장을 실시하지 않는 한 RDF층 내부에서 생화학적 반응열이 생성되더라도 $40^{\circ}C$를 상회할 가능성은 매우 희박할 것으로 판단된다. RDF 저장시 발생하는 가스는 대부분 $CO_2$였으며, 미량이지만 $H_2$, CO, $CH_4$도 검출되었다. 가연성 가스는 저장 후 2개월 동안은 발생하지 않았으며, 하계에는 타 계절에 비해 상대적으로 고농도로 검출되었다. 발생가스와 온도 및 $CO_2$$H_2$농도의 상관성은 높게 나타나지 않았지만, 정의 상관관계를 나타내었다. 저장한 RDF의 성상(수분, 발열량, 분화물)은 실험개시 전의 RDF분석결과와 실험종료 후 분석결과에서는 큰 차이가 나타나지 않았다. 따라서 RDF의 안전 저장을 위해서는 (1) 반입되는 RDF성상관리, (2) RDF가 2개월 이상 장기간 체류하는 데드스페이스가 발생하지 않고 선입선출이 확보되는 저장조 설계, (3) 사일로 내부에 최소 3개 이상의 지점에서 온도를 측정하여 상시감시하고 $40^{\circ}C$이하로 관리, (4) 발생가스는 CO, $CO_2$, $H_2$, $CH_4$ 등의 가연성가스를 모두 측정 감시하는 것이 바람직하지만, 최소 $CO_2$$H_2$는 상시감시하고 각각 1%와 100ppm 미만으로 관리, (5) 배풍기 등을 이용한 상시 환기실시, (6) 하계에는 대량저장이 이루어지지 않도록 저장조 운용계획 수립 등을 실시해야 한다.

  • PDF

반응표면분석법을 이용한 제진기의 목메임 방지 개선 및 레이크 최적화 (A Study on the Optimization of Anti-Jamming Trash Screen with Rake using by Response Surface Method)

  • 선상원;이원;홍석범
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.230-236
    • /
    • 2020
  • 제진기는 배수펌프장, 하수처리장, 발전소 등 유입 수로 전단에 설치되어 부유 협잡물의 유입을 차단하는 장치이다. 제진기의 스크린 사이의 협잡물이 끼는 목메임 현상과 노끈류가 제거되지 못하여 물의 유입로의 감소 또는 제진기 파손을 유발하는 문제점이 발생하고 있다. 본 논문에서는 목메임과 노끈류 끼임으로 인한 파손이 주로 발생하는 에이프런을 제거하고 스크린을 확장하여 대체하였다. 그리고 스크린 사이 공간에 내측 레이크를 추가하여 목메임과 노끈류를 제거하도록 개선하는 확장형 레이크를 사용하는 방식으로 설계하였다. 기존의 제진기 레이크의 허용응력을 만족하는 내측 레이크를 설계하기 위하여 레이크 수직 길이와 보강단면의 두께 값을 변수로 하여 실험계획법에 따라 실험점을 결정하고, 구조해석 툴인 ANSYS static structural module과 통계분석 툴인 R software를 이용하여 반응표면분석법에 따른 형상 최적화를 진행하였다. 결정된 최적 설계점 레이크 길이 210.2mm와 보강단면 두께 2mm에서 반응표면분석법 결과와 구조해석의 결과의 상대 오차는 1.63% 이다. 파일럿 제진기를 실제 크기로 제작하여 실증 실험을 수행하였으며 97%이상 목메임과 노끈류를 제거가 가능함을 확인하였다.