ICT Convergenced Cascade-type Incubator for mass production of microalgae (미세조류 대량생산을 위한 ICT 융합 계단식 연속 배양 장치)

  • Lee, Geon Woo;Lee, Yong Bok;Yoo, Yong Jin;Baek, Dong Hyun;Kim, Jin Woo;Kim, Ho Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.379-386
    • /
    • 2021
  • This study was undertaken to develop a cascade-type continuous culture system (CCCS) that combines both ICT and biotechnology (BT), for the mass production of microalgae. This system is capable of maintaining the essential culture conditions of pH, temperature, carbon dioxide, and illuminance control, which are key parameters for the growth of microalgae, and is economical for producing microalgae regardless of the season or location. It has the added advantage of providing stable and high productivity. In the current study, this system was applied to culture microalgae for 71 days, with subsequent analysis of the experimental data. The initial O.D. of the culture measured from incubator 1 was 0.006. On the 71st day of culture, the O.D.s obtained were 0.399 (incubator 1), 0.961 (incubator 2), 0.795 (incubator 3), and 0.438 (incubator 4), thereby confirming the establishment of continuous culture. Thus, we present a smart-farm based on ISMC (in-situ monitoring and control) for a mass culture method. We believe that this developed technology is suitable for commercialization, and has the potential to be applied to hydroponics-based cultivation of microalgae and cultivation of high-value-added medicinal plants as well as other plants used in functional foods, cosmetics, and medical materials.

Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water(2) (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능(2))

  • Park, Geun-Woo;Lee, Eung-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.15-19
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 하는 지열히트펌프의 Pond Loop형 열교환기를 개발하기 위하여 미국에서 상용화된 Slim-Jim 열교환기와 본 연구에서 자체설계, 제작한 Pond-loop type의 열교환기를 유동이 없는 유출수조 내에서 수조온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량의 변화를 측정하였다. 그 결과 유출수를 Heat Source로 사용하는 경우 Slim-Jim에서는 $8,000{\sim}11,000 kcal/hr$의 열량이 전달되었고, 자체 제작한 열교환기에서는 $11,000{\sim}16,000kcal/hr$의 열량이 전달되었다. 유출수를 Heat Sink로 사용할 경우 Slim-Jim에서는 $2,500{\sim}7,000 kcal/h$의 열량이 전달되었고, 자체제작한 열교환기의 경우, $6,800{\sim}14,00 kcal/hr$의 열량이 전달되었다. 측정된 열전달량을 바탕으로 총괄열전달계수를 구한 결과 Slim-Jim 열교환기의 경우 $210{\sim}340 kcal/hr\;m^2{\circ}C$, 자체개발한 열교환기의 경우 $350{\sim}590 kcal/hr\;m^2{\circ}C$로 나타나 자체 개발한 열교환기의 열전달 성능이 비교적 우수함을 입증하였다.

  • PDF

NUMERICAL CHANGES OF THE COLIFORM BACTERIA IN A RECIRCULATING AQUARIUM (순환여과수조수의 대장균군)

  • PARK Soo-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.1
    • /
    • pp.5-8
    • /
    • 1978
  • Numerical changes of coliform bacteria in a recirculating aquarium were measured as fouling indicator. The contamination of the filter bed was mainly due to the food given to fishes, the fecal materials and the additional supply of water polluted already. Abundance of the bacteria in the aquarium was controlled by the physiochemical factors of water quality. Of these factors, pH was the main factor. Under the water temperature $20^{\circ}C$, if pH was controlled at lower than $5\~6$, the bacteria did not flourish seriously. Under the water temperature over $30^{\circ}C$, the bacterial growth was markedly decreased regardless of the pH value, and the bacterial flora seemed to be active in growth under temperature condition lower than $30^{\circ}C$.

  • PDF

갈조류 모자반, Sargassum fulvellum (Turner) C. Agardh의 성숙과 초기생장

  • 황은경;박찬선;김철원;백재민;손철현
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.119-120
    • /
    • 2003
  • 우리나라에 분포하는 모자반류는 모두 28종으로 알려져 있으며 (이와 강 2002) 이 가운데 식용으로 이용되는 것은 모자반 (S. fulvellum)이 대표적이다. 모자반의 양식은 주로 서남해 지역에서 이루어지고 있으며 이들의 종묘생산은 자연에서 생식기탁이 성숙되는 4-5월경에 이루어지는데, 유배의 대량 방출을 위한 성숙 모조의 다량 확보가 어렵고 일시에 유배의 대량 방출을 유도하기 위한 성숙 유도 기법의 연구는 전무한 실정이다. 따라서 이 연구에서는 모조의 실내 배양을 통하여 유배의 대량 방출을 위한 성숙 유도 기법과 배양 조건별 엽체의 성숙 및 난방출율을 구하여 모자반의 조기채묘에 유용한 자료로 사용하고자 하였다. 또한 채묘된 발아체의 초기생장에 필요한 최적 배양 환경을 구명하고자 하였다. 모자반 모조는 전남 진도군 조도 지역의 수심 3-5m에서 채집하였으며, 채집 즉시 실험실로 운반하여 유수식 사육 수조에 수용하였다. 성숙 유도는 20$\ell$ 플라스틱 bottle을 사용하였으며, 성숙률의 정량화를 위하여 암생식기탁을 절단하여 수차례 멸균해수에서 세척후 멸균된 5cm직경의 petri dish에 멸균해수20$m\ell$와 함께 수용하여 Multi-chamber incubator에서 배양하였다. 배양조건은 5개 온도조건 (5, 10, 15, 20, $25^{\circ}C$)과16:8h의 장일 광주기 조건으로하였으며 조도는 80 $\mu$molm$^{-2}$ s$^{-1}$로 하였다. 모든 실험구는 3반복 실험하였으며 2일 간격으로 생식기탁의 생장 및 성숙 그리고 난방출 여부를 현미경하에서 측정하였다. 난이 방출된 모조로부터 유배를 분리하여 3개 조도 구간 (30, 60, 100 $\mu$molm$^{-2}$ s$^{-1}$)과 5개 온도 구간 (5, 10, 15, 20, $25^{\circ}C$)의 조합인 15개 배양 조건하에서 엽체의 길이생장을 측정하였다. 생식기탁으로부터 난의 방출은 15$^{\circ}C$와 2$0^{\circ}C$ 조건에서 배양 2일후부터 방출되기 시작하였으며, 배양 9일후 2$0^{\circ}C$ 조건에서 가장 높은 96.7$\pm$5.8%의 난방출율을 보였다. 또한 15$^{\circ}C$ 조건에서는 배양 9일후 76.7%의 난방출율을 보였다. 1$0^{\circ}C$$25^{\circ}C$ 조건에서는 배양 11일까지 36.7%의 난방출율을 나타내어 온도 조건에 따라 난방출 비율에 차이를 보였다. 따라서 이러한 실내 배양 결과를 다량의 모조를 조기에 성숙시키기 위해 모조 수용 수조의 수온을 자연수온보다 2~5$^{\circ}C$ 높은 12~15$^{\circ}C$ 조건으로 유지하여 15일간의 수조 관리 후 모조의 대량 유배 방출을 유도할 수 있었다. 모조 성숙을 위한 사육 수조의 수온을 2$0^{\circ}C$ 이상으로 가온할 경우 엽체의 끝녹음을 유발하였으며 가온에 따르는 가온 비용이 수반되므로 엽체의 난방출율이 70% 이상에 도달하는 15$^{\circ}C$ 조건으로 유지하는 것이 경제적일 뿐만 아니라 엽체의 건전도 유지에도 바람직하였다. 유배의 초기생장은1$0^{\circ}C$와15$^{\circ}C$의 온도조건에서 길이생장이 빠르게 증가하여, 배양 35일 후 15$^{\circ}C$와 60 $\mu$molm$^{-2}$ s$^{-1}$의 조건에서 3.9$\pm$0.2mm로 가장 높은 값을 나타내었다. 엽체의 초기 길이생장은 15$^{\circ}C$, 60 $\mu$molm$^{-2}$ -s$^{-1}$의 조도 조건에서 가장 우세하였으며, 다음으로 30과 100 $\mu$molm$^{-2}$ s$^{-1}$의 조건 순으로 나타났다. 2$0^{\circ}C$$25^{\circ}C$의 온도 조건에서는 각각 1.8~2.1mm로 길이생장에 있어 유의한 차이가 없는 것으로 나타났다.

  • PDF

Study on fluid flow characteristics of aquarium for optimum environment (최적 양식환경을 위한 수조식 양식장내의 유동특성에 관한 연구)

  • 정효민;정한식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.108-117
    • /
    • 1998
  • This study was performed to analyze the fluid flow characteristics and the temperature distribution of the aquarium for fish breeding. In this study, the finite volume method and turbulence k-$\varepsilon$ model with the SIMPLE computational algorithm are used to study the water flow in the aquarium. The calculation parameters are the circulating flow rate and the basin depth, and the experiments were carried out for the water flow visualization This numerical analysis gives reasonable velocity distributions in good agreement with the experimental data. As the results of the three dimmentional simulations, the sectional mean velocity increased as the sectional mean temperature increases for constant basin depth, and the mean velocity increased more rapidly for small basin depth than that of large basin depth, The mean velocity and temperature can be expressed as the function of the circulating flow rates and the basin depth.

  • PDF

Temperature and Velocity Characteristics in a Land Aquaculture Tank with a Various Inlet Flowrates (육상 수조식 양식장의 유입 유량 변화에 따른 온도와 속도의 특성)

  • Kim, Se-Hyun;Shin, You-Sik;Jun, You-Sin;Seo, Jong-Soo;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2083-2088
    • /
    • 2003
  • This study was performed to analyze the velocity and temperature distributions of the land aquaculture tank for fish breeding. In this study, we analyzed the velocity and temperature distributions in aquarium tank, and the finite volume method and standard ${\kappa}-{\epsilon}$ turbulence model with the SIMPLE computational algorithm are used to study the water flow in the aquarium. The main calculation parameters of the aquarium tank are the inlet flow rate with from 0.5 to 2.0L/M.

  • PDF

월성 2,3,4호기 비상급수계통 성능평가에 관한 연구

  • 오광석;김창호;이중섭;김선철;오종필
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.362-367
    • /
    • 1996
  • CANDU-6형 원자력발전소인 월성 2,3,4호기 비상급수계통의 성능을 평가하기 위하여 설계기능 수행과 관련된 변수로서 격납건물내 집수조(sump) 온도와 열수송계통으로 주입되는 냉각재온도를 사용한 분석을 수행하였다. 이 온도들은 NTU(Number of Transfer Unit)방법을 이용한 비상노심 냉각계통 열교환기의 열전달속도와 열전달계수의 해석을 열평형관계식과 함께 조합한 프로그램을 사용하여 계산하였다. 또한 증기발생기 급수량과 추후 수조에 공급되는 보충수에 대한 설계요건을 검토하였다. 이러한 변수와 설계요건은 비상급수계통이 발전소 정상 열제거기능 상실후 노심의 붕괴열제거에 유효한 열침원으로서의 기능을 수행함을 보여 주었다. 또 격납건물의 건전성 유지와 관련된 집수조내 최고온도가 허용치 이하로 유지되었다.

  • PDF

A Study on the Estimation of Temperature Dependance in Tissue by Ultrasound (초음파에 의한 조직의 온도의존성에 관한 연구)

  • 이상민;박형배
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 1989
  • In this paper, the temperature dependence of tissue is estimated by measuring the attenuation coefficient and the propagation velocity of ultrasonic reflection signal. And, on the basis of expeiments, the possibility of non- invasive temperature estimation is considered. Specimens in the experiment are acryl 1)late. muscle, fat and liver of pig. The temperature of specimen is controlled by water bath which is able to adjust temperature a quarter of a degree. Through the series of experiments, we conformed that the ultrasonic parameters have lin earity to a certain extents with the change of tissue's temperature. And we expect that noninvasive temperature estimation of tissue can be realized after several preconditions be satisfied with the standard experiment conditions and a great number of base data.

  • PDF

Effect of Curing Temperature and Time on Measuring Fundamental Properties of Asphalt Mixture (양생온도 및 시간이 아스팔트 혼합물의 기초특성치 측정에 미치는 영향)

  • Kim, Kwang-Woo;Hong, Sang-Ki;Oh, Heung-Lak;Lee, Soon-Jae
    • International Journal of Highway Engineering
    • /
    • v.4 no.4 s.14
    • /
    • pp.13-21
    • /
    • 2002
  • This study examines the importance of conditioning temperature and period before measuring fundamental properties of asphalt mixture. Marshall specimens were made and cured in the air for one day and conditioned by submerging at $60^{\circ}C$ water for 30 min before loading. It was observed that if the specimen was cured in a lower (or higher) than normal lab temperature ($25^{\circ}C$) before submerging, the measured values were not consistent. Indirect tensile strength (ITS) was also measured on the specimens cured at different temperatures. Although there is no regulation specifying how long the specimen should be conditioned before testing, it is recommended that the conditioning time be for the specimen to be at $25^{\circ}C$. Test must be conducted for the specimen cured well before conditioning for desired test. If curing temperature was lower or higher than normal, and mixture was not properly cured, then test results would not be reliable. This study showed how long the specimen should be submerged at $60^{\circ}C$ for Marshall test and conditioned at $25^{\circ}C$ for ITS test for the specimens cured in different temperature.

  • PDF

Natural Convection in a Water Tank with a Heated Horizontal Plate Facing Downward (아래로 향한 수평가열판이 있는 수조에서의 자연대류)

  • Yang, Sun-Kyu;Chung, Moon-Ki;Helmut Hoffmann
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.301-316
    • /
    • 1995
  • experimental and computational studies ore carried out to investigate the natural convection of the single phase flow in a tank with a heated horizontal plate facing downward. This is a simplified model for investigations of the influence of a core melt at the bottom of a reactor vessel on the thermal hydraulic behavior in a oater filled cavity surrounding the vessel. In this case the vessel is simulated by a hexahedron insulated box with a heated plate Horizontally mounted at the bottom of the box. The box with the heated plate is installed in a water filled hexahedron tank. Coolers are immersed in the U-type water volume between the box and the tank. Although the multicomponent flows exist more probably below the heated plate in reality, present study concentrates on the single phase flow in a first step prior to investigating the complicated multicomponent thermal hydraulic phenomena. In the present study, in order to get a better understanding for the natural convection characteristics below the heated plate, the velocity and temperature are measured by LDA(Laser Doppler Anemometry) and thermocouples, respectively. And How fields are visualized by taking pictures of the How region with suspended particles. The results show the occurrence of a very effective circulation of the fluid in the whole How area as the heater and coolers are put into operation. In the remote region below the heated plate the new is nearly stagnant, and a remarkable temperature stratification can be observed with very thin thermal boundary. Analytical predictions using the FLUTAN code show a reasonable matching of the measured velocity fields.