• Title/Summary/Keyword: 수조 온도

Search Result 129, Processing Time 0.034 seconds

Development of a curling pad performance test system to support Korea curling team (국가대표 컬링 대표팀 지원을 위한 컬링 패드 성능 시험 시스템 개발)

  • Kim, Taewhan;Lee, Sangcheol;Kil, Sekee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.25-30
    • /
    • 2020
  • In this study, a test system which can test performance of curling pad was developed to support Korea curling team. The developed system consists of a water tank, a mechanical pad driving system that can perform sweeping movement using a curling pad on surface of ice made by the water tank, and temperature sensors monitoring ice and air temperatures. To control the temperature of ice and humidity/temperature of air around the ice, all system are installed in a chamber that can isolate the developed system from external environment. Eight kinds of curling pads were tested using the developed system. Test result showed that each curling pad revealed different rate of ice temperature increasing. The pad with the highest rate of ice temperature rising was found to be the same as the most preferred pad by the athletes. Therefore, it was confirmed that the method of measuring change of ice temperature by the sweeping performed in this study is an effective method to test the performance of the pad.

선어회의 가공ㆍ유통에 있어서 얼음물 침지 및 유통온도의 검토

  • 심길보;정호진;김태진;이기봉;이근우;김건배;조영제
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2003.05a
    • /
    • pp.109-110
    • /
    • 2003
  • 우리 국민들은 살아서 펄떡펄떡 뛰는 활어를 조리사가 소비자가 보는 앞에서 바로 회로 처리한 것을 가장 선호하고 있으므로 양식장에서 살아 있는 상태로 활어를 수송하고 있다. 그렇지만 현재의 활어수송 방법은 활어를 운반하기 위하여 많은 량의 해수를 함께 싣고서 수송하고 있으므로 필요 없는 대량의 물을 나르게 되어 수송경비가 증가된다. 또한, 횟집에서는 활어수조 등의 시설비가 들어가며 횟집에서는 수조를 자주 청소해야 하는 단점이 있을 뿐만 아니라 수조관리를 잘못하게 되면 활어가 죽기도 한다. (중략)

  • PDF

Wave Propagations in the Underwater Anechoic Basin in KRISO (무향 수조 내에서의 음파 전파 특성 연구)

  • 김시문;최영철;박종원;임용곤
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.363-368
    • /
    • 2001
  • Because of rapid damping of light and electromagnetic wave, acoustic wave has been widely used for underwater communication. However, the propagation of the acoustic wave is highly dependent on the environment such as water properties(temperature, pressure, salinity), bottom and surface conditions, etc.. This paper deals with the surface reflection effect on the wave propagation in the underwater anechoic basin in KRISO. Both theortical and experimental approaches are performed and the results are compared.

  • PDF

Heat Transfer Performance of Pond loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Wafer (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능)

  • Park Geun-Woo;Kim Jin-Sang;Lee Eung-Youl
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.86-93
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 지열히트펌프의 지초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

Heat Transfer Performance of Pond Loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Water (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능)

  • Park, Geun-Woo;Kim, Jin-Sang;Lee, Eung-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.445-450
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 하는 지열히트펌프의 기초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고, 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500 kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고, 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한총괄열전달계수, U와 실험값을 통해 유추한U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

Growth and Cold Temperature Tolerance of Cultured Juvenile Small Yellow Croaker, $Larimichthys$ $polyactis$ and Yellow Drum, $Nibea$ $albiflora$ (양식산 참조기 및 수조기 미성어의 계절별 성장 경향과 저수온 내성 특성)

  • Kang, Hee-Woong;Kang, Duk-Young;Han, Hyon-Sob;Cho, Kee-Chae
    • Korean Journal of Ichthyology
    • /
    • v.24 no.1
    • /
    • pp.41-47
    • /
    • 2012
  • In the present study, we investigated the characteristic of growth and the tolerance of cold temperature in small yellow croaker and yellow drum. The results shows that the growth of yellow drum were faster than those of small yellow croaker with high food convergency efficiency. In condition factor (CF), the results shows that the values of yellow croaker and yellow drum were significantly higher in September, respectively. In mortality according to cold shock, two fishes was died under $4.7^{\circ}C$ in slow temperature descending test, but was both died under $9^{\circ}C$ in acute temperature descending test.

An Experimental Study on the Measurement of Water Surface Discharge Temperature of High-Temperature Bubble Injected into Cylindrical Acrylic Water Tank (원통 아크릴 수조로 주입된 고온 기포의 수면 배출 온도 측정에 관한 실험적 연구)

  • SeokTae Yoon;YongJin Cho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.99-105
    • /
    • 2023
  • Submarines, which require a high degree of survivability, are among the most critical combat weapon systems in military strategic assets. Conventional submarines need air to operate their propulsion systems. Exhaust gases released into the water during snorkel navigation heat the surrounding fluid, producing a temperature wake. This wake, in turn, reduces the submarine's survivability. In this study, we conducted a preliminary experiment on the temperature traces formed by an underwater submarine's waste discharge. For this purpose, we collected propulsion system and navigation condition data from domestically introduced submarines and developed an experimental system to measure the temperature traces. As a result, we observed that high-temperature bubbles injected into the tank broke down into smaller sizes, and their temperature dropped to levels similar to the surrounding fluid. This observation was confirmed using a thermocouple sensor. Consequently, the thermal imaging system designed to measure the temperature trace of the water's surface did not detect any significant temperature traces.

An Experimental Study on the Water Temperature Sensitivity of Exotic Fishes (외래어종의 수온 민감성에 대한 실험 연구)

  • Son, Minwoo;Park, Byeoung Eun;Byun, Jisun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.483-483
    • /
    • 2018
  • 우리나라 하천 생태계에서 외래어종은 토착 어류의 개체수를 빠르게 감소시키고 서식처에서 우점종이 되어 생태계 교란을 야기하고 있다. 이러한 현안의 문제점을 해결하기 위해 외래어종과 관련된 많은 연구가 진행되고 있다. 본 연구는 우리나라 대표적 외래어종인 배스와 블루길을 대상으로 수온에 따른 서식처 형성을 관찰한다. 그 후 계절별로 형성된 서식처 안에서 수온을 조절하여 외래어종의 생태환경에 따른 민감성을 분석하는 것을 목적으로 수행하였다. 실험실 연구를 진행하는 동안 외래어종이 서식처를 형성할 때 민감하게 반응하는 수온 차가 계절에 따라 달라짐을 발견하였다. 이 사실을 증명하기 위해 농업용 저수지로부터 채집한 배스와 블루길을 길이 12 m, 깊이 0.6 m, 폭 1 m의 하천과 유사한 자연적 환경이 갖추어진 수조에 이식한 후, 외래어종이 서식처를 형성할 때 계절에 따라 어떻게 반응하는지 면밀히 관찰하였다. 수조를 3개의 구역으로 나누어 좌측 끝단을 히터를 설치한 온수대, 우측 끝단을 냉각기를 설치한 냉수대, 중앙은 온도 조절장치를 설치하지 않은 중수대로 구분하여 실험하였고 계절 마다 수온을 조절하며 수온 차와 서식처 형성의 상관성 분석이 진행되었다. 실험 진행 시 수온을 제외한 수조 안 환경은 동일하게 유지하였다. 실험 결과, 동계에는 실험실 수조의 평균 수온이 $12.88^{\circ}C$이고 어류는 각 구간별 수온의 차이가 $1^{\circ}C$ 이하에도 민감하게 반응하며 조금이라도 수온이 높은 구역에 서식처를 형성하였다. 춘계에는 평균 수온 $16.15^{\circ}C$가 되면서 어류가 온수대에 서식처를 형성하기는 하나 각 구간별 $1^{\circ}C$ 정도의 차이에는 중수대까지 서식처를 형성하였다. 즉 동계보다는 수온 차이에 둔감하게 반응하는 특성을 보였다. 또한 춘계에서 하계로 넘어가는 과도기에 수조의 평균 수온이 $21^{\circ}C$로 올라가자 외래어종은 각 구간별 수온 차이와는 관계없이 이미 서식처로 형성했던 온수대를 넘어 수조 전체에 좀 더 확산된 형태의 서식처를 형성하였다. 하계에는 수조의 평균 수온이 $25.67^{\circ}C$였으며 수온을 조절하여 관찰한 결과 외래어종은 약 $24^{\circ}C$ 수온보다 낮은 냉수대에 서식처를 뚜렷하게 형성하는 모습을 보였다. 즉 외래어종은 $20{\sim}24^{\circ}C$ 정도의 수온에 서식처를 가장 선호 하며 동계에는 수온이 가장 높은 곳, 하계에는 가장 낮은 곳에 형성하는 것으로 판단된다. 실험을 진행하는 동안 수조 내 구역의 구분을 위해 공통으로 설치된 가림판 부근에 외래어종의 군락이 형성된 것을 통해, 향후에는 외래어종의 서식처 형성과 장애물과 같은 지형적인 요인이 미치는 영향에 관한 연구가 필요할 것으로 판단된다.

  • PDF

하나로 냉중성자원 헬륨 이중배관의 특성

  • Choe, Ho-Yeong;Kim, Min-Su;Son, U-Jeong;Lee, Mun;Han, Jae-Sam;Jo, Seong-Hwan;Heo, Sun-Ok;An, Guk-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.361-361
    • /
    • 2011
  • 하나로 냉중성자원(CNS: Cold Neutron Source)은 원자로 수조내 반사체 탱크에 위치한 수직 조사공에 설치되어 하나로 노심에서 발생하는 열중성자를 감속재인 액체 수소층을 통과시켜 냉중성자를 생산한다. 생성된 냉중성자는 유도관을 통하여 냉중성자 산란장치에 공급되어 이용 연구에 활용된다. 감속재로 사용되는 수소는 헬륨냉동계통의 운전에 따라 수소가 수조내기기 집합체(IPA: In Pool Assembly) 내로 이동되어 액화되어지므로, 극저온의 헬륨가스의 흐름이 중요하다. 헬륨냉동기에 의해 만들어진 극저온인 헬륨은 IPA 내의 수소와 열교환을 하기 위해서 배관을 통해 이동되며, 열손실없이 전달하기 위하여 헬륨 배관은 진공층이 형성된 이중배관으로 설계되어 있다. 헬륨 이중배관은 공급 및 회수 배관으로 구성되어 있으며, 헬륨 배관의 외관에 진공층을 20개의 구간으로 나누어 제작 및 설치되었으며, 각각의 진공도를 유지하고 있다. 이 논문에서는 하나로 냉중성자원 헬륨 이중배관의 특성과 헬륨냉동계통의 운전 및 정지시 온도 변화에 따른 이중배관 진공도의 변화를 분석하였다.

  • PDF