• Title/Summary/Keyword: 수조수관리계통

Search Result 2, Processing Time 0.016 seconds

Design of the Heat Exchanger in Pool Water Management System of a Research Reactor and Estimation of the Pool Water Temperature Using CFD (전산유체해석을 이용한 연구용원자로 수조수관리계통 열교환기 설계 및 수조수 온도 예측)

  • Jeong, Namgyun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.45-51
    • /
    • 2016
  • The pool water management system, which is installed for purification of the coolant in the pools and the primary cooling system of a research reactor, removes the decay heat from the reactor core when the primary cooling system stops. It also removes the heat generated from the irradiated objects in the service pool and the spent fuels in the spent fuel storage pool to keep the temperature of the pools within a limited value. In this study, the heat exchanger of the pool water management system is designed by CFD method using a commercial code Flowmaster, and the temperature of the pools is estimated along the time to conclude the design and operation method of the pool water management system.

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.