• Title/Summary/Keyword: 수정진동자 가스센서

Search Result 7, Processing Time 0.023 seconds

Development and research of gas sensor for monitoring sulfur compounds (황화물 측정용 가스센서의 연구개발)

  • Kim, Ki-Young;Kim, Jong-Min;Ham, Young-Hwan;Chang, Yong-Keun;Kim, Jong-Deuk;Chang, Sang-Mok
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.33-39
    • /
    • 1994
  • A quartz crystal microbalance (QCM) sensor system for the detection of odorants, especially environmental pollutant, has been constructed by depositing various phospholipids, activated carbon and lead compound pigment onto the surface of the QCM. The characteristics of a QCM operating at 9 MHz deposited with phosphatidyl- choline were analysed. An explanation is given for different odorant affinities based on the monolayer properties of phospholipids. The identification of odorants is discussed in terms of a comparison of their normalized resonant frequency shift patterns and relative response intensities calculated from the response areas. Applying the lead compound pigment coated QCM, it was possible to detect sulfur compound specifically. Using a number of different lipid-coated QCMs, odorants could be identified by comparing the response patterns.

  • PDF

Principle of Sensor Systems by using a Quartz Crystal and Their Applications (수정진동자를 이용한 센서시스템의 원리와 응용)

  • Kim, Jong-Min;Chang, Sang-Mok;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.655-668
    • /
    • 2009
  • The principle and applications of quartz crystal sensors based on the three basic concepts for mass, viscosity, and viscoelastic changes are reviewed. In the general discussion the basic principle of quartz crystal and realization of a resonant frequency-resonant resistance diagram are described in detail. As examples of their applications, gas sensing with a carbon-coated quartz crystal, determination of the blood coagulation factor, an electrochemical analysis and crystallization analysis are reported. The possibility of developing new biosensors and chemical sensors is discussed on the basis of these results.

Sensing and Degradation Properties in the QCM Gas Sensor Coated with the PVC and GC Blended Liquid (PVC 및 GC물질의 혼합액을 코팅한 QCM가스센서의 센싱 및 열화특성)

  • 장경욱;김명호;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.483-486
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal rnicrobalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid GC materials varing with the blended amount of PVC(Po1y Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of 20.4 respectively. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

Sensing and Degradation Characteristics in the QCM Gas Sensor Coated with the PVC and PC (PVC 및 PC 혼합액을 코팅한 QCM 가스센서의 센싱 및 열화 특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.176-179
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We obtained the principal component analysis (PCA) from the frequency change due to the absorption of gas. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

Fabrication and organic gas response characteristics of the copolymer LB films (공중합체 LB막의 제작과 유기가스 반응 특성)

  • 신훈규;최용성;장정수;권영수
    • Electrical & Electronic Materials
    • /
    • v.9 no.2
    • /
    • pp.180-187
    • /
    • 1996
  • The use of preformed copolymers and their cross-linking have been attempted in order to improve the intrinsic fragility of monolayers and Langmuir-Blodgett (LB) films and to make their technological applications. It has shown that an imidization followed a polyion-complexation can stabilize the LB films against heat and solvents. And, when the polymer structure was properly designed, concurrent removal of the alkyl tails together with imide formation could be accomplished. In this paper, the monolayers of the polymers which were polyion-complexed with PAA at the air-water interface can be transferred onto solid substrates such as porous fluorocarbon membranes filter and quartz crystal microbalance. The properties of the monolayers and the LB films will be discussed by .pi.-A isotherms, FT-IR, DSC, deposition ratio, QCM, and SEM. In addition, it was attempted to investigate the response characteristics of polymer LB films to the organic gases by the use of QCM.

  • PDF

Fabrication of TiO2/polyelectrolyte thin film for a methyl mercaptan gas sensor (메칠멜캅탄 가스센서용 TiO2/전해질폴리머 박막 제조)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lee, Mi-Jai;Kim, Sei-Ki;Lim, Tae-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.221-226
    • /
    • 2010
  • Quartz crystal microbalance (QCM) gas sensor to detect methyl mercaptan ($CH_3SH$) gas was fabricated by depositing $TiO_2$ nanoparticles and polyelectrolyte on the electrode of QCM. The $TiO_2$/poly(sodium 4-styrenesulfonate) (PSS) thin film fabricated by a layer-by-layer self-assembly (LBL-SA) method showed a high surface area and increased the sensitivity of gas sensor. When the QCM sensors coated with triethanolamine (TEA) or ($TiO_2$/PSS) were exposed to methyl mercaptan gas (1.0 ppm), the frequency shifts of QCM with TEA casting film and $TiO_2$/PSS thin film were ca. 9 Hz and ca. 24 Hz, respectively. As the bilayer number of ($TiO_2$/PSS) increased, the frequency shift of QCM sensor with ($TiO_2$/PSS) thin film was gradually increased. In addition, the frequency shift of QCM sensor was gradually increased as the concentration of methyl mercaptan gas increased from 0.5 ppm to 2.0 ppm. In this study, the surface morphology and sensor property of QCM sensor coated with ($TiO_2$/PSS) thin film were measured.

Sensing and Degradation Properties in the Quartz Crystal Microbalance Coated with the PVC and the Lipid Blended Materials (지질과 PVC의 혼합액을 감응막으로 도포한 수정진동자 가스센서의 센싱 및 열화특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Choi, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.44-47
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the sensitive and the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We also measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF