• Title/Summary/Keyword: 수정진동자

Search Result 101, Processing Time 0.024 seconds

Electrochemical Determination of Glucose in Sea Water (해수 중 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.73.2-77
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the detennination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a QUartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution and the effect of the concentration is analyzed to find a proper relation between the concentration and the measurements. It is fOlmd that a linear relation between the concentration of less than 900 Dpm and the peak current when a constant potential of -180 m V vs. Ag/ AgCI reference is applied.

  • PDF

Quartz Crystal Microbalance Modified by a Novel Vapor Diffused Molecular Assembly Technique and Measurement of Chiral Mandelic Acid (기상확산 자기조립화법에 QCM수식과 Madelic Acid 키랄물질 측정)

  • Kim, JongMin;Kim, SeungJin;Woo, SunYoung;Jang, SukHee;Kim, Woo-Sik;Chang, SangMok
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.574-582
    • /
    • 2010
  • In this study, the possibility of a quartz crystal micro-balance(QCM) modification of crystallization of L-Penicillamine and D-Penicillamine with a Vapor Diffused Molecular Assembly Technique and its application to the R-(-)-Mandelic acid and S-(+)- Mandelic acid measurement was investigated. The 3-dimensional structures of L-Penicillamine and D-Penicillamine on the surface of QCM were verified to be different from each other through QCM and AFM analyses. The D-Penicillamine modified QCM had specific recognition to the R-(-)-Mandelic acid, but L-Penicillamine modified QCM had no specificity to the R-(-)-Mandelic acid and S-(+)- Mandelic acid. From these results, it was known that the QCM could be modified with various selective meterials via VDMA, and the chiral isomer such as a Mandelic acid isomer could be detected by using a modified QCM.

The Chacteristics of Resonant Resistance Change of the Piezoelectric Quartz Crystal Depending on the Polymer Polarity (고분자의 극성에 따른 수정진동자 공진저항의 변화 특성)

  • Park, Ji Sun;Park, Jung Jin;Lee, Sang Rok;Chang, Sang Mok;Kim, Jong Min
    • Applied Chemistry for Engineering
    • /
    • v.18 no.1
    • /
    • pp.71-76
    • /
    • 2007
  • We have demonstrated the resonant resistance pattern changes of the polymer film in the quartz crystal analysis by the function of the molecular polarity phase transition phenomena. PVA and PMMA/PVAc blend films were used as hydrophilic and/or hydrophbic film, respectively. In the comparison between the hydrophilic shows the pattern changes near by the phase transition temperature. For more detailed explanation, the static capacity in the oscillation parameter was measured and the morphology of Au quartz crystal electrode was studied by AFM. It is suggested that the different resonant resistance pattern change is reliable in the condition of different polarity, and the conclusion is important to analysis of the real mechanism a normal quartz crystal experiments.

A study on the feedback control system for near field scanning optical microscope based on the tuning fork oscillator (수정 진동자를 이용한 근접장광학계 (Near-Field Scanning Optical Microscope) 제작 및 특성연구)

  • 윤선현
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.267-272
    • /
    • 1999
  • We attached a fiber tip on the branch of a quartz crystal oscillator in order to make a feedback control system for near field optical microscope. The electrical impedance of the quartz crystal oscillator depends on the distance between the surface of the sample and the tip caused by the surface damping. Using this method, we can directly monitor the distance between the sample and the tip without inserting extra beam which might give extra optical noise. We characterize the XY scanning resolution and the amplitude of the vibrating tip and the Z-dependent decay of the evanescent wave.

  • PDF

Introduction to Electrochemical Quartz Crystal Microbalance Technique for Leaching Study of Metals (금속 침출연구를 위한 전기화학적 미소수정진동자저울 기술 소개)

  • Kim, Min-seuk;Chung, Kyeong Woo;Lee, Jae-chun
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.25-34
    • /
    • 2020
  • Electrochemical Quartz Crystal microbalance is a tool that is capable of measuring nanogram-scale mass change on electrode surface. When applying alternating voltage to the quartz crystal with metal electrode formed on both sides, a resonant frequency by inverse piezoelectric effect depends on its thickness. The resonant frequency changes sensitively by mass change on its electrode surface; frequency increase with metal dissolution and decrease with metal deposition on the electrode surface. The relationship between resonant frequency and mass change is shown by Sauerbrey equation so that the mass change during metal dissolution can be measured in real time. Especially, it is effective in the case of reaction mechanism and rate studies accompanied by precipitation, volatilization, compound formation, etc. resulting in difficulties on ex-situ AA or ICP analysis. However, it should be carefully considered during EQCM experiments that temperature, viscosity, and hydraulic pressure of solution, and stress and surface roughness can affect on the resonant frequency. Application of EQCM was shown as a case study on leaching of platinum using aqueous chlorine for obtaining activation energy. A platinum electrode of quartz crystal oscillator with 1000 Å thickness exposed to solution was used as leaching sample. Electrogenerated chlorine as oxidant was purged and its concentration was controlled in hydrochloric acid solution. From the experimental results, platinum dissolution by chlorine is chemical reaction control with activation energy of 83.5 kJ/mol.

Development and research of gas sensor for monitoring sulfur compounds (황화물 측정용 가스센서의 연구개발)

  • Kim, Ki-Young;Kim, Jong-Min;Ham, Young-Hwan;Chang, Yong-Keun;Kim, Jong-Deuk;Chang, Sang-Mok
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.33-39
    • /
    • 1994
  • A quartz crystal microbalance (QCM) sensor system for the detection of odorants, especially environmental pollutant, has been constructed by depositing various phospholipids, activated carbon and lead compound pigment onto the surface of the QCM. The characteristics of a QCM operating at 9 MHz deposited with phosphatidyl- choline were analysed. An explanation is given for different odorant affinities based on the monolayer properties of phospholipids. The identification of odorants is discussed in terms of a comparison of their normalized resonant frequency shift patterns and relative response intensities calculated from the response areas. Applying the lead compound pigment coated QCM, it was possible to detect sulfur compound specifically. Using a number of different lipid-coated QCMs, odorants could be identified by comparing the response patterns.

  • PDF

Principle of Sensor Systems by using a Quartz Crystal and Their Applications (수정진동자를 이용한 센서시스템의 원리와 응용)

  • Kim, Jong-Min;Chang, Sang-Mok;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.655-668
    • /
    • 2009
  • The principle and applications of quartz crystal sensors based on the three basic concepts for mass, viscosity, and viscoelastic changes are reviewed. In the general discussion the basic principle of quartz crystal and realization of a resonant frequency-resonant resistance diagram are described in detail. As examples of their applications, gas sensing with a carbon-coated quartz crystal, determination of the blood coagulation factor, an electrochemical analysis and crystallization analysis are reported. The possibility of developing new biosensors and chemical sensors is discussed on the basis of these results.

Density-based Topology Design Optimization of Piezoelectric Crystal Resonators (압전 수정진동자의 밀도법 기반 위상 최적설계)

  • Ha, Youn Doh;Byun, Taeuk;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.63-70
    • /
    • 2014
  • Design sensitivity analysis and topology design optimization for a piezoelectric crystal resonator are developed. The piezoelectric crystal resonator is deformed mechanically when subjected to electric charge on the electrodes, or vice versa. The Mindlin plate theory with higher-order interpolations along thickness direction is employed for analyzing the thickness-shear vibrations of the crystal resonator. Thin electrode plates are masked on the top and bottom layers of the crystal plate in order to enforce to vibrate it or detect electric signals. Although the electrode is very thin, its weight and shape could change the performance of the resonators. Thus, the design variables are the bulk material densities corresponding to the mass of masking electrode plates. An optimization problem is formulated to find the optimal topology of electrodes, maximizing the thickness-shear contribution of strain energy at the desired motion and restricting the allowable volume and area of masking plates. The necessary design gradients for the thickness-shear frequency(eigenvalue) and the corresponding mode shape(eigenvector) are computed very efficiently and accurately using the analytical design sensitivity analysis method using the eigenvector expansion concept. Through some demonstrative numerical examples, the design sensitivity analysis method is verified to be very efficient and accurate by comparing with the finite difference method. It is also observed that the optimal electrode design yields an improved mode shape and thickness-shear energy.

Redox Property of Self-Assembled Viologen Monolayers with Various Concentration using QCM (수정진동자를 이용한 Viologen 자기조립 단분자막의 농도변화에 의한 전하이동 특성 연구)

  • Park, Sang-Hyun;Lee, Dong-Yun;Kang, Hye-Young;Park, Jae-Chul;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.63-64
    • /
    • 2006
  • 본 연구에서는 광에너지를 화학적인 에너지로 변환할 때, 디바이스의 전하전달 매개를 위한 electron transfer mediator로서 널리 이용되는 Viologen이 자기조립화된 수정진동자률 전기화학법의 하나인 순환전압전류법(Cyclic Voltammetry)을 이용하여 산화 환원 반응 (redox reaction) 특성과 주사속도와 피크전류와의 상관관계를 분석하였다. 먼저 수정진동자를 친수 처리한 후, 메탄올 용액과 아세토니트릴 용액을 섞은 용매에 Viologen 분자를 자기조립 (self-assembly)하여, 전해질 용액의 농도 변화에 따른 산화 환원반응 특성과 피크전류의 값을 측정하였다 주사 속도를 2 배씩 증가하여 피크전류와의 상관관계를 조사한 결과, 선형적인 증가를 보였으며, 이를 통해 가역적인 반응(reversible reaction)이 일어났음을 확인할 수 있었다. 또한, 산화 환원 반응과 동시에 측정된 수정진동자의 공진 주파수(resonant frequency) 변화로부터 전하이동(charge transfer) 특성에 의해 반응에 참가한 이온의 질량을 알 수 있었다.

  • PDF