• Title/Summary/Keyword: 수정안

Search Result 584, Processing Time 0.026 seconds

핫이슈 - 출판문화산업진흥법 개정안 국회 본회의 통과

  • Im, Nam-Suk
    • 프린팅코리아
    • /
    • v.14 no.6
    • /
    • pp.50-51
    • /
    • 2014
  • 최재천 국회의원이 발의하고 국회 교육문화체육관광위원회가 수정한 도서정가제 관련 '출판문화산업 진흥법 일부개정법률안(수정안)'이 지난 4월 29일 열린 국회 본회의에서 통과됐다. 본 개정안은 5월 중 개정법률이 공포되고, 6개월 경과 후인 11월부터 시행될 예정이다.

  • PDF

Limbal Lensectomy with or without Anterior Vitrectomy for the Management of Lens Subluxation (비외상성 수정체이탈 환자에서 시행한 윤부 수정체절제술)

  • Chang, Ju-Hee;Cha, Soon-Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.243-251
    • /
    • 2007
  • Purpose : This study was conducted to assess the surgical outcomes of limbal lensectomy with or without anterior vitrectomy for the management of lens subluxation. Materials and Methods : The medical records of 20 consecutive patients (33 eyes) with lens subluxation who had undergone limbal lensectomy with or without anterior vitrectomy from February 1999 to January 2004 were retrospectively reviewed. Results : All the patients, except one high axial myopic patient, were implanted with scleral sutured posterior chamber intraocular lens. We evaluated the preoperative, postoperative visual acuity and postoperative complications and compared the results in group I (limbal lensectomy with anterior vitrectomy, 27 eyes) to those in group II (limbal lensectomy without anterior vitrectomy, 6 eyes). The preoperative best-corrected visual acuity was 0.21 and postoperative best-corrected visual acuity was improved by 2 lines or more in all 27 eyes in group I, and in 5 eyes in group II (p>0.05). The most frequent postoperative complication was intraocular lens dislocation in four eyes (14.8%) in group I alone. No retinal detachment occurred in either group, even in patients with high myopia. Conclusion : Limbal lensectomy without anterior vitrectomy improved visual acuity similarly to limbal lensectomy with anterior vitrectomy without significant increase of postoperative complications. This results of this study suggest that anterior vitrectomy is not necessarily required for the management of lens subluxation.

  • PDF

Determining the existence of unit roots based on detrended data (추세 제거된 시계열을 이용한 단위근 식별)

  • Na, Okyoung
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.2
    • /
    • pp.205-223
    • /
    • 2021
  • In this paper, we study a method to determine the existence of unit roots by using the adaptive lasso. The previously proposed method that applied the adaptive lasso to the original time series has low power when there is an unknown trend. Therefore, we propose a modified version that fits the ADF regression model without deterministic component using the adaptive lasso to the detrended series instead of the original series. Our Monte Carlo simulation experiments show that the modified method improves the power over the original method and works well in large samples.

Design of the Finite Schematic Eye with the Crystalline Lens with GRIN Index (실안의 수정체 굴절률 분포를 갖는 정밀모형안 설계)

  • Kim, Bong-Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.167-170
    • /
    • 2007
  • In this study, clinical data for emmetopia in young Koreans was taken in order to design the finite schematic eye, which had optical properties of real eyes including spherical aberration, astigmatism, field curvature and distortion. Furthermore, the crystalline lens with GRIN medium was optically analyzed, and the finite schematic eye with the GRIN crystalline lens was designed.

Coloration Mechanism and Growth of Synthetic Colored Quartz (유색 수정의 발색 기구 및 성장)

  • 이영국
    • Korean Journal of Crystallography
    • /
    • v.9 no.2
    • /
    • pp.159-167
    • /
    • 1998
  • 천연에서 발견되는 유색수정은 자수정, 연수정, 황수정, 청수정, 녹수정, 장미수정 등 그 색의 종류에 따라 크게 6가지로 분류되며 발색 기구에 따라 색중심(color center), 전이금속 불순물(transition metal impurity), 산란(scattering), 전하이동(charge transfer) 등 4가지로 분류된다. 이들은 천연에서 고온고압의 열수가 냉각되면서 그 안아 녹아있던 광물질이 재결정하여 생성된 것이다. 이러한 유색수정은 실험실에서도 합성되며 그 방법은 천연 수정의 생성 과정과 유사하다. 그러나 천연수정 중의 일부는 실험실에서 성장하기가 거의 불가능하기 때문에 다른 방법을 이용하여 유사한 색을 가지게 한다. 본 논문에서는 불순물 원소의 종류 및 수정 격자내의 위치, 최외각 전자의 상태에 따라 색이 달라지는 것을 고찰하고 이러한 유색수정을 합성하는 원리에 대하여 논하고자 한다.

  • PDF

Design of the Finite Schematic Eye with GRIN Crystalline Lens Considering Iris Eccentricity (홍채 편심을 고려한 GRIN 수정체를 갖는 정밀모형안 설계)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.61-64
    • /
    • 2011
  • Purpose: The purpose of this study was to design the finite model eye with GRIN lens similar to actual eye, which considered the effect of iris eccentricity on eyes. Methods: By using the finite model eye with Radial GRIN and Spherical GRIN, which were designed previously, the location of iris was eccentrically located by 0.5 mm in the direction of nose to show the same eye as actual one. For ray trace and design, Code V program of Optical Research Associates (ORA) was adopted. Results: Designed model eye was compared to actual eye depending on iris eccentricity and the model eye which showed reduced value was corrected according to actual eye to design the finite model eye. Conclusions: Ocular optical systems considered the point that iris was a rotational asymmetry and designed the finite model eye with GRIN lens, which was similar to actual eye, by considering the effect of iris eccentricity on eye.