• Title/Summary/Keyword: 수전설비

Search Result 112, Processing Time 0.022 seconds

전기동향

  • Korea Electrical Manufacturers Association
    • 전기산업
    • /
    • v.8 no.5
    • /
    • pp.114-120
    • /
    • 1997
  • PDF

A Proposed High Voltage Distribution System of the Customer Inside for Reducing Power Loss (수용가내부 고압배전시스템의 전력손실감소효과)

  • Park, Hyung-Joon;Yun, Man-Soo;Chung, Chan-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.39-44
    • /
    • 2005
  • This paper is about the new distribution system of the electric customer inside. The power loss in the distribution system of the customer is disregarded and rarely managed so for. But, economically, this loss is not small quantity to ignore. So, in this paper, we suggest that the new distribution system of the electric customer inside by simply changing the locations of power transformer and other power facilities which is located inside of the customer. And we also show that the power loss is decreased with this systematic changing by approximated calculation.

A Study on the Improvement of Insulation cover for Instrument Transformer Used In Power Receiving System of Construction Sites (건설현장의 수전설비에서 사용되는 계기용변성기 절연커버의 성능개선에 관한 연구)

  • Gil, Hyoung-Jun;Choi, Chung-Seog;Kim, Hyang-Kon;Han, Woon-Ki;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2005
  • There are many risk factors of electrical shock caused by a minimum of protective devices, loose working environments, deterioration of installations at temporary power installations of construction sites. An insulation cover for instrument transformer(MOF) used in 22.9[kV] class power receiving system hasn't shown good performance in terms of electrical safety because of short clearance between insulation cover and each input and output wire junction part. The insulation cover is easily moved by outside environment as wind or rain because of different size between insulation cover and busing, also can be leaded to breakdown by tracking. Therefore, we have proposed the insulation cover which effectively can prevent from electrical disaster in this paper, and a utility model patent had been registered already. To decrease the electric field concentrated on specific part, we had roundly designed the shape of insulation cover and the clearance between cover and live part was adjusted to be longer than the existing thing. The proposed insulation cover was evaluated by using the electric field solution program.

인입설비의 요점

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.5 s.113
    • /
    • pp.81-85
    • /
    • 1986
  • 전기설비는 기능을 향상 유지하기 위한 올바른 설계, 시공 및 적절한 보수, 관리를 해야 된다. 설비관리에서 일상적인 보수는 모터의 베어링이나 브러시의 마모, 형광등이나 전구의 교체등 기능면의 유지에 중점을 둔 점검, 정비가 입체로 되어 있다. 또한 전기설비를 안전하게 사용하기 위해 실시하는 전기설비 관리도 정전, 감전, 화재를 미연에 방지하기 위해 중용한 사항이다. 여기서는 고압수전의 중소규모이 자가용 전기설비를 중심으로 인입설비, 수변전설비, 배전설비 및 사용설비의 보수, 관리의 체크포인트에 대하여 설명하기로 한다.

  • PDF

전력사용과 에너지절약

  • 최수현
    • 전기의세계
    • /
    • v.35 no.4
    • /
    • pp.213-220
    • /
    • 1986
  • 본고의 내용은 다음과 같다. 1. 전기에너지의 기여 2. 에너지 절약형 신발전기술 2.1 전자류체발전기술 2.2 연료전지발전기술 3. 전력수송효율의 향상 3.1 송배전계통합리화 3.2 송전기술 3.3 통신, 제어 및 효율적 운영 4. 전기에너지의 효율적 이용기술 4.1 절전형 전기기기 4.2 전동설비 운전제어 4.3 수전설비의 합리화 4.4 조명기술 4.5 전력관리 전산화 4.6 심야전력의 이용(에너지저장)

  • PDF

A Study of M.O.F turn-ratio difference from customer's equipment accident (고객 파급고장에 타른 M.O.F 비율오차 이상현상에 대한 고찰)

  • Cho, Seong-Hyeun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.627-628
    • /
    • 2005
  • 22.9KV-Y 배전선로의 특고압 수전선비에 계량장치로 부설되어 운영중인 계기용변성기 M.O.F(Metering Out Fit)는 계기용변압기와 계기용변류기를 하나의 상자 속에 수납한 것으로 전력량계와 조합시켜서 전려측정의 변성장치로 사용되고 있다. 계량장치의 사용되고 있는 계기용변성기는 고객과 공정거래 확립을 위하여 상시 정해진 비오차 특성을 만족하여야 한다. 그러나 고객구내 수전설비에서 파급고장이 발생시 과전류로 인하여 계기용변성기의 권선에 큰 충격이 가해져 비오차특성에 문제점이 발생하여 이에 따른 현상으로 고찰하고자 한다.

  • PDF