• Title/Summary/Keyword: 수전설비

Search Result 113, Processing Time 0.028 seconds

A Prediction Scheme for Power Apparatus using Artificial Neural Networks (인공신경망을 이용한 수전설비 고장 예측 방법)

  • Ki, Tae-Seok;Lee, Sang-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.6
    • /
    • pp.201-207
    • /
    • 2017
  • Failure of the power apparatus causes many inconveniences and problems due to power outage in all places using power such as industry and home. The main causes of faults in the Power Apparatus are aging, natural disasters such as typhoons and earthquakes, and animals. At present, the long high temperature status is monitored only by the assumption that a fault occurs when the temperature of the power apparatus becomes higher. Therefore, it is difficult to cope with the failure of the power apparatus at the right time. In this paper, we propose a power apparatus monitoring system as an efficient countermeasure against general faults except for faults caused by sudden natural disasters. The proposed monitoring system monitors the power apparatus in real time by attaching a thermal sensor, collects the monitored data, and predicts the failure using the accumulated information through learning using the artificial neural network. Through the learning and experimentation of artificial neural network, it is shown that the proposed method is efficient.

Error Analysis for Temperature Big Data of Hydropower Collected by IoT sensors (IoT 센서로 수집한 수전 설비의 온도 데이터를 이용한 오류 빅데이터 분석)

  • Joo, Eun-Jin;Hong, Jang-Eui
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.553-555
    • /
    • 2017
  • 수전 설비 시스템은 전력 회사에서 3 상 전원을 받는 설비로, 전기를 공급받기 위한 설비이다. 정전이나 제품생산설비의 중단은 기업에 있어서는 경제적 손실이 매우 큰 사고일 수 밖에 없다. 요즘은 IoT 센서를 이용한 수전설비 관리 시스템의 활용이 늘어나고 있는 추세이다. IoT 센서를 이용한 수전 설비의 구축에서 정확한 상태 값의 센싱과 수집된 값의 전송, 그리고 정확성 판단에 대한 이슈들이 고려되어야 하며, 또한 기기간 통신을 통해 실시간 상호작용으로 수전설비의 고장을 어떻게 예방할 것인가에 대한 것이 중요하다. 본 연구에서는 수전 설비의 실시간 감지와 모니터링을 위한 목적으로 기존의 고장 및 오류 정보를 기반으로 하는 빅데이터 분석을 통해 발생 가능한 고장 및 오류를 사전 예측할 수 있도록 정보를 제공하는 것에 주안점을 두었다.

A study on electric facilities of water supply according to the revisions of electric field standard (전기분야 관련기준 개정에 따른 수도사업장 수전설비 구성방안 연구)

  • Sul, Jae-Hun;Park, Jong-Sun;Cho, Yong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.414-415
    • /
    • 2011
  • 한국전력공사의 전기공급약관 개정('10.11.01)으로 저압 수전범위가 현행 계약전력 100kW 미만에서 500kW 미만으로 확대됨에 따라 500kW 미만의 경우 수용가에서 저압 또는 고압 수전방식 선택이 가능하여 수도사업장 수전방식 선정 기법 및 저압 수전설비 표준구성방안을 수립하였으며, '10.1.8. "전기설비기술기준의 판단기준"의 개정으로 서지보호기 설치의무사항이 신설되어 수도사업장 구내 배전계통 서지보호기 설치구성방안을 수립하였다.

  • PDF

Construction Of Uninterruptible Power System by Reliable Incoming Power Method (신뢰도 높은 수전방식에 의한 무(無)정전 전원설비 구축방안)

  • Choi, Jin-Sung;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.367-371
    • /
    • 2007
  • Large capacity UPS and emergency generators are being installed and operated at the specific target of important electric facilities that need uninterruptible power supply by the method of countermeasure against power failure for the less reliable incoming power method. Recently, CTTS (Closed Transition Transfer Switch) is being used as uninterruptible power transfer switch at the Common sources of electricity, generator and multiple generators. In this paper, construction plans for uninterruptible power supply system has been suggested in which CTTS has been applied to the secondary of incoming power generator for reliable common dual system method. By briefing the construction of incoming power facilities, large capacity UPS, emergency generator installation space and investment saving effects can be achieved.

  • PDF

수전설비 단선 결선도에 대한 변

  • 김광수
    • Electric Engineers Magazine
    • /
    • v.197 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • 내선규정에 수진설비 표준결선도에 대한 해석과 이들 결선도의 변형 또는 응용한 단선도에 대하여 필자의 의견을 제시하여 전력기술인 여러분과 의견을 나누고자 한다.

  • PDF

전기설비의 안전관리2

  • 최연수
    • Electric Engineers Magazine
    • /
    • v.204 no.8
    • /
    • pp.34-43
    • /
    • 1999
  • 진상용 콘덴서는 역률개선을 위하여 수전설비에 많이 이용되며 콘덴서의 설치위치는 통풍이 좋은 장소, 부식성 가스나 진동이 없는 장소에 설치하도록 한다.

  • PDF

수전설비의 사례에서 트립사고와 그 체크포인트

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • no.6 s.102
    • /
    • pp.88-95
    • /
    • 1985
  • 수전설비에서 트립사고의 원인으로서는 전기기기 배전의 고장(단락, 지락)에 의한 것, 과부하의 의한 것 등 당연히 동작해야 될 트립 외에 동작해서는 안될 때에 트립되는 이른바 Nuisance Tripping (불필요동작)이라고 하는 케이스가 있다. 담당 기술자를 곤란하게 하는 현상인데 그 발생요인을 이해해둔다면 대책을 수립하여 방지하는 것은 곤란한 일이 아니다. 과전류에서는 변압기 여자돌입전유가 주로 생각되는데 지로의 경우에는 미소한 사고에너지를 검출, 증폭하고 있기 때문에 몇 가지의 요인을 들수 있다. 여기서는 주로 지로에 의한 요인을 가급적 사례를 기초로 하여 들고 체고 포인트를 설명하기로 한다.

  • PDF