• Title/Summary/Keyword: 수위저감효과

Search Result 164, Processing Time 0.025 seconds

Proposal for the groundwater based countermeasures to secure water resources considering regional characteristics of water resources vulnerable areas (국내 수자원 이용 취약지역의 지역 특성을 고려한 지하수 기반 수자원 확보 방안 제시)

  • Kim, Geon;Lee, Jae-Beom;Agossou, Amos;Yang, Jeong-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.3
    • /
    • pp.191-203
    • /
    • 2022
  • This study is a follow-up study of vulnerable areas according to the vulnerability assessment of groundwater resource management in Korea. In this study, an optimal operation plan for groundwater resource management was proposed for areas vulnerable to groundwater resource management in Korea derived from previous studies. Prior to presenting the optimal operation plan for groundwater resource management, this study grasped the current status of changes in groundwater level and seawater penetration area for vulnerable areas using MODFLOW, a groundwater flow analysis program. As a result of the analysis using basic data for 10 years from 2009 to 2018, the groundwater level fell and the sea infiltration area increased. The final purpose of this study, the optimal operation plan for groundwater resource management, was selected as a total of four alternatives that can be expected to have positive effects to increase groundwater level and reduce seawater penetration. As a result of analyzing the amount of change in groundwater level and seawater penetration by applying the selected optimal operation plan, positive effects were found in all methods. It is expected that the optimal operation plan for groundwater resource management proposed in this study will be applied not only to vulnerable areas of groundwater resources in Korea but also to areas requiring development to establish efficient groundwater resource management measures.

Reduction Effect of EMI Conducted Noises and Improvement of Harmonic Spectrum through RPWM Control (RPWM 제어를 통한 전도성 EMI 잡음의 억제와 고조파 스펙트럼의 향성)

  • 박석하;김양모
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.3
    • /
    • pp.116-123
    • /
    • 1999
  • SMPS는 수위칭 소자를 이용하여 효과적으로 전력을 변환시킨다. 여기에서 가장 중요한 파라미터가 스위칭 주파수이다. 스위칭 주파수를 증가시킴에 따라 전원장치의 소형경량화가 가능하다. 그러나 기존 PWM 컨버터에서는 치명적인 단점으로 스위칭 주파수를 증가시킴에 따라 스위칭 손실 및 EMI 문제를 야기한다. 특히 SMPS의 동작은 상당히 큰 di/dt와 dv/dt에 기인한 EMI 전도성 잡음을 발생시킨다. EMI를 감소시키는 방법들로는 고전적이고 고가인 입력필터 혹은 주 전력단에 능동필터를 첨가하는 방법 등이 있어 왔다. 본 논문에서는 DC/DC 포워드 컨버터에 대해 EMI 잡음 발생원 및 잡음 경로를 분석하였다. SMPS에서 방출되는 전도성 잡음은 스위칭 주파수와 그 고주파 주파수에 집중되어 있다. 따라서 본 연구에서는 일정 출력전압에는 큰 영향 없이 스위칭 주파수를 약간씩 변조하게 되는 RPWM 제어를 통하여 전도성 잡음의 주파수 대역을 측면대역으로 분사시키어 전체 첨두치를 저감시키고, 고조파 스펙트럼을 개선할 수 있다.

  • PDF

An Experimental Study of Runoff Reduction Using Infiltration Facility (건축물에 적용된 우수침투시설의 유출저감효과에 관한 실험적 연구)

  • Park Jae-Roh;Kwon Hyok
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.37-44
    • /
    • 2005
  • The main object of this study is to develop the infiltration facility that it can be used in grounds, parking areas, roads, pathway, housing etc. As a result, it is much alike in the infiltration method of facility to use permeable concrete, permeable hole and be filled with broken stones. And through this experiment, it was perceived the truth that the state of ground, the groundwater level, buildings around them, the history of submerging and the applicable infiltration facilities are the key. To verify how much the infiltration facility reduce the outflow, we set up the infiltration facility in the test area. In result, it reduced the outflow 89% in 24 mm rainfall, 93% in 12 mm, 51% in 140 mm, 75% in 64 mm and 80% in 54 mm. As the rainfall rate increased, the infiltration increased up to the limited rainfall. And in the limited rainfall, we knew that the infiltration was reduced suddenly. Infiltration is closely related to the state of ground, the rain interval etc. and we will analyze these conditions through the continuous monitoring.

Evaluating the Trapping Efficiency of Vegetative Buffer Systems on Sediment Reduction Using SWAT model (SWAT 모델을 이용한 수변 완충지역에서 비점오염원 저감효율 평가)

  • Kim, Ik-Jae;Son, Kyong-Ho;Kim, Jeong-Kon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1819-1823
    • /
    • 2007
  • 유역에서 상류 유역 또는 수변을 따라 자연 자원을 이용하여 조성되어야 할 완충지대는 비점오염의 영향을 줄이기 위한 중요한 최적 관리공법이다. 교란된 토지 피복과 수변 완충지대를 관리 및 복원할 때 같은 지형조건이라도 식생 종류, 발달정도, 토양조건에 따라 오염물 제거효과가 다를 수 있으며, 최소 완충지대 길이도 제거 오염물질 대상별로 적합하게 설계되고 해석되어야 한다. 본 연구의 목적은 용담댐 유역에서 SWAT 모델을 이용하여 식생 완충지대의 비점오염원 저감 모의 재현성을 평가하는 것이였다. 소유역의 관측값과 모델 예측값에 대한 모델의 검 보정이 선행되었으며 그 중에서 가장 높은 모델 효율을 가지는 소유역에서 three zone concept의 90m 수변완충지대를 지방하천을 경계로 하여 토지 피복도를 변화시켜 SWAT 모델에 적용하였다. 이 때 교목으로는 포플러 (Populus, 30m)을 적용하였고, 포플러의 높이 및 Leaf area index를 조정하여 관목 지대(30m)에 입력하였다. 잔디 지대(30m)는 자연초지를 선택하였다. 또한 지형변수(average slope)와 Manning's coefficient을 수변완충지대의 조건에 고려하여 변화를 주었고 이에 따른 유출량 및 유사량, T-N, T-P의 변화율을 조사하였다. 또한 5, 10, 30m의 식생 여과대를 밭 지역에만 적용하여 오염물의 저감 효율을 평가하였다. SWAT 모델은 각 소유역에서 발생된 전반적인 유출량과 수질변수의 추세를 잘 예측하였으며 정자천 소유역이 선택되었다. 모의된 완충지대에서는 연평균 940 m3/ha의 유출량이 감소되는 것으로 유사농도는 28.7 %의 저감효과를 보였다. 그러나 T-N, T-P의 농도는 오히려 증가되었는데 본 연구에서 고려된 보다 수변완충지대를 조성할 때 지하수 수위, 식생 성장변화 등과 같은 보다 정확한 설계 인자 산출 및 모델 DB 개발이 유역모델에 포함되어야 할 것으로 판단되었다.한 해결책을 얻어내는 상호보완적인 결과를 추구한다. 그가 디자인하는 작품은 전형적인 이미지를 내포하지 않는다. 즉 그의 작품은 기존의 가치와 이념적인 것은 배제하고, 창의적인 개념을 도출하였다.형모서리는 건물 특화 성격이 강하므로 불가피할 경우 소형 액센트 광고 위치를 미리 벽면으로 할애하는 것이 경관 및 입면계획에 유리한 것으로 분석되었다. 불확실도 해석모형 등의 새로운 기능을 추가하여 제시하였다. 모든 입출력자료는 프로젝트 단위별로 운영되어 data의 관리가 손쉽도록 하였으며 결과를 DB에 저장하여 다른 모형에서도 적용할 수 있도록 하였다. 그리고 HyGIS-HMS 및 HyGIS-RAS 모형에서 강우-유출-하도 수리해석-범람해석 등이 일괄되게 하나의 시스템 내에서 구현될 수 있도록 하였다. 따라서 HyGIS와 통합된 수리, 수문모형은 국내 하천 및 유역에 적합한 시스템으로서 향후 HydroInformatics 구현을 염두에 둔 특화된 국내 수자원 분야 소프트웨어의 개발에 기본 토대를 제공할 것으로 판단된다.았다. 또한 저자들의 임상병리학적 연구결과가 다른 문헌에서 보고된 소아 신증후군의 연구결과와 큰 차이를 보이지 않음을 알 수 있었다. 자극에 차이가 있지 않나 추측되며 이에 관한 추후 연구가 요망된다. 총대장통과시간의 단축은 결장 분절 모두에서 줄어들어 나타났으나 좌측결장 통과시간의 감소 및 이로 인한 이 부위의 통과시간 비율의 저하가 가장 주요하였다. 이러한 결과는 차가운 생수 섭취가 주로 결장 근위부를 자극하는 효과를 발휘하는 것이 아닌가 해석된다. 이와 같은 연구결과를 통해 생다시마를 주원료로 개발된 생다시마차와 생다시마 음료가 만성 기능성 변비 증세를 개선하는 효능이 잠재적으로 있음을 확인하였다. 그러나 생약제재의 변비약 수준으로 변비 개선 효능을 증대하기 위해서는 재료 배합비의 개선이나 대장 운동기능을 향상시키는 유효성분의 보강 등이 필요하다는 점도 알 수 있었다.더불어 산화물질 해독에 관

  • PDF

A Plot Scale Experiment to Assess the NPS Reduction of Sediment Trap for Non-irrigated Cropland (침사구의 밭 비점오염 저감효과 평가를 위한 포장실험 연구)

  • Park, Tae-Yang;Kim, Sung-Jae;Jang, Jeong-Ryeol;Choi, Kang-Won;Kim, Sang-Min
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.97-103
    • /
    • 2011
  • The purpose of this study was to analyze the pollutant reduction effect for non-irrigated crop land by nonpoint source pollution control. For a field scale monitoring, 6 plots (5m width and 22m length) and 3 sediment traps were installed. At the outlet of each plot, the stage gauges were installed for runoff monitoring. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Through the artificial irrigation, runoff from the plots were monitored. The SS, TOC, T-N, T-P, COD, NTU of sampled water were analyzed by standard methods. The SS, TOC, T-N, T-P, COD, NTU concentration of initial runoff were 15.00, 1.54, 5.27, 0.07, 4.72, 0.45mg/L, respectively. Four hours later than the initial runoff, the concentration was changed to 1.00, 0.94, 4.06, 0.01, 0.60, 0.33 mg/L, respectively. As a result of artificial irrigation, three out of four sediment traps were filled with runoff water from the experimental plots. One sediment trap was not filled with runoff water because the artificial irrigation was not supplied for two experimental plots. The stage of sediment traps were gradually lowered. However, the water quality didn't showed a decrease trend as the stage went down because the suspended solid was not equally collected during the water sampling.

Effect of Dam Operation on the Spatial Variability of Downstream Flow (댐운영에 따른 하류하천 유량의 공간적 변동성 평가)

  • Jeong Eun Lee;Jeongwoo Lee;Chul-gyum Kim;Il-moon Chung
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.627-638
    • /
    • 2023
  • This study aimed to evaluate the spatial variability of downstream river flow resulting from the operation of the Gimcheon Buhang Dam in the Gamcheon watershed. The dam's effects on flood reduction during the flood season and on increasing streamflow during the dry season-two main functions of multipurpose dams-were quantitatively analyzed. Streamflow data from 2013 to 2021 for the study waterhsed were simulated on a daily basis using SWAT-K (Soil and Water Assessment Tool - Korea) model. Comparison of the simulated and observed values found goodness of fit values of 0.75 or higher for both the coefficient of determination and the Nash-Sutcliffe model efficiency coefficient. The spatial analysis of the dam's effect on flood reduction focused on the annual maximum flood: rates of flood reduction at the four stations ranged from 8.5% to 25.0%. The evaluation of streamflow increase during times of low flow focused on flow duration curves: in particular, compared to the case without an upstream dam, the average low flow at the four sites increased from 33% to 198%.

Dam Effects on Spatial Extension of Flood Discharge Data and Flood Reduction Scale I (홍수 유출자료의 공간확장과 홍수저감효과에 대한 댐 영향 분석 I)

  • Kim, Nam Won;Jung, Yong;Lee, Jeong Eun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.209-220
    • /
    • 2015
  • In this study, the effects of changed environment on spatial extension of flood discharge data which is generating discharge data at ungauged watersheds. Especially, effects of dams on spatial extensions of flood discharge data and on natural flow generation were studied. This is somehow an intial trial of flood discharge data generation for heterogeneous watersheds because of dam installation. Data extensions have been performed based on the flood discharge data from YeoJoo water gauge station located on the Nam-Han River. For the evaluation of flood discharge data spatial extension under dam effects and producing natural flow, 41 flood events associated with YeoJoo water gauge station were selected from 1986 to 2010. When flood discharge data were extended based on YeoJoo water gauge station, 77% of selected flood events were over the satisfaction ranges (NSE>0.5) of Nash-Sutcliffe Efficiency for model validation. Extended flood discharge data at Yangpyung has 0.84 NSE obtained from spatial data extension based on YeoJoo water gauge station. Generated natural flow at YeoJoo was influenced strongly by Chungju Dam which has larger effects on streamflow at YeoJoo than Hoangsung Dam. Observed peak discharges after the 1986 of Chungju Dam installation were smaller than those of the obtained natural flow. Through these results, spatial extension of flood discharge data with installed dams works efficiently for ungauged watersheds and natural flow can be generated using extended flood discharge data.

Improvement and Application of Pump Station Operating System and Economic Analysis of the Application (빗물펌프장 운영시스템 개선 및 적용과 경제효과분석)

  • Joo, Jin- Gul;Yoo, Do-Guen;Yang, Jae-Mo;Jung, Dong-Hwi;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • In low-lying districts of urban areas, pump stations were built to protect flooding by the heavy rain. Particularly, the automatic pump operation system was installed for efficiency in the pump stations of Seoul. However, the effective pump operation is difficult under existing operating system because the system only performs operation by reservoir depth. This study would like to improve the real time operating system suggested by Jun et al.(2007) and to apply the system Gasan 1 pump station in Seoul. For various design rainfall events, maximum water levels simulated by the suggested system were 10~70cm lower than results by the existing system. And overflow volume at upstream manholes were 50% reduced. We converted the flood control effects by establishment of the suggested system to economic indicators. To obtain the same effect, approximately 4.9 billion won needs to expand pump capacities or 3.2~6.9 hundreds million won needs to construct storm water detention on upstream area. The suggested system could improve the flood control stability by efficient operation of the existing pump station.

A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model (도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가)

  • Tak, Yong Hun;Kim, Jae Dong;Kim, Young Do;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.395-406
    • /
    • 2016
  • Population and development are concentrated by urbanization. Consequently, the usage of underground area and the riverside area have been increased. By increasing impermeable layer, the urban basin drainage is depending on level of sewer. Flood damage is occurred by shortage of sewer capacity and poor interior drainage at river stage. Many of researches about flood stress the unavailability of connection at the river stage with the internal inundation organically. In this study, flood calculated considering rainfall and combined inland-river. Also, using urban runoff model analyze the overflow of sewer. By using results of SWMM model, using flood inundation analysis model analyzed internal drainage efficiency of drainage system. Applying SWMM model, which results to flood inundation analysis model, analyzes internal drainage efficiency of drainage system under localized heavy rain in a basin of the city. The results of SWMM model show the smoothness of internal drainage can be impossible to achieve because of the influence of the river level and sewer overflow appearing. The main manholes were selected as the manhole of a lot of overflow volume. Overflow reduction scenarios were selected for expansion of sewer conduit and instruction retention pond. Overflow volume reduces to 45% and 33~64% by retention pond instruction and sewer conduit expansion. In addition, the results of simulating of flood inundation analysis model show the flood occurrence by road runoff moving along the road slope. Flooded area reduces to 19.6%, 60.5% in sewer conduit expansion scenarios.

An Experimental Study on Cylindrical Countermeasures for Dissipation of Debris Flow Energy (원통형 대책 구조물의 토석류의 에너지 저감 효과에 대한 실험적 연구)

  • Kim, Beom-Jun;Han, Kwang-Do;Kim, Ho-Seop;Choi, Clarence E.;Yune, Chan-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • In this study, to investigate the effect of cylindrical countermeasure on the flow characteristics of debris flow, a series of small-scale tests were conducted using a flume with cylindrical baffles. Various heights and row numbers of installed baffles were considered as a test condition. High speed cameras and laser level sensors were also installed at the top and side of the channel, respectively, to capture the debris flow dynamics before and after baffles. Based on test results, the energy dissipation of debris flow due to baffles was analyzed. Test results showed that baffles can significantly reduce the velocity and flow depth of debris flows. The energy dissipation effect of baffles also increase as the increase of height and row number of baffles.