Evaluation for conjunctive operation of multi-regional water supply system through risk analysis (위기대응 취약성 분석을 통한 광역상수도 연계운영 평가)

  • Hwang, Jinsoo;Choi, Taeho;Hong, Gonghyun;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.269-279
    • /
    • 2019
  • This study would present a risk analysis method to evaluate stable tap water supply in a multi-regional water supply system and propose a measure for the evaluation of the effect of the conjunctive operation of the multi-regional water supply system using this. Judging from the vulnerability for the crisis response of the entire N. multi-regional water supply system, as compared to the result of Scenario 1 in which no conjunctive pipes were operated, it was found that in Scenario 2, in which conjunctive pipes were partially operated, the vulnerability of crisis response decreased by about 30.6%, and as compared to Scenario 3, the vulnerability of crisis response decreased by 86.2%. In setting a plan for stable tap water supply in N multi-regional water supply system, using the estimated value and the method for the evaluation of the vulnerability of crisis response by pipe, by interval and by line, it is judged that this can be utilized as a basis for the judgment of the evaluation of the operation or the additional installation of conjunctive pipes.

Performance Evaluation Systems in Water Distribution Network (상수관망의 성능평가를 위한 진단체계 구축)

  • Kim, Ju-Hwan;Kim, Jung-Hyun;Lee, Doo-Jin;Woo, Hyung-Min;Bae, Cheol-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.864-868
    • /
    • 2008
  • Water transmission and distribution systems play a important role to deliver safe and clean water and are responsible for the most direct impacts of water utilities to customers. Although the performance of WDS(Water Distribution Systems) should be evaluated by a certain standards, interests has not been in WDS and developed due to invisible, hard-working and insufficient information in the evaluation process in Korea till now. The investigations and researches were carried out to develop software to assist the evaluation of WDS with respects to hydraulics, water quality and structural analysis methods. The methodologies have been developed which can be used to estimate the performance to water distribution network and software are implemented by the process. Developed systems are consisted with database, analysis techniques, simulation models, decision support systems and other tools. The concepts and functions are introduced in this paper and the performance index are discussed for accurate assessment of water distribution systems.

  • PDF

Application of Transient and Frequency Analysis for Detecting Leakage of a Simple Pipeline (누수탐지를 위한 천이류와 주착수분석 적용 연구)

  • Kim, Hyung-Geun;Kim, Hyun-Soo;Lee, Mi-Hyun;Kim, Sang-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1065-1071
    • /
    • 2005
  • Many techniques of leak detection in pipeline systems have developed based on the propagation wave speeds and wave attenuation. In this paper, the transient analysis methodology is used for calculating the wave speed in the plastic pipe and a frequency analysis methodology is developed for leakage detection in water pipe networks. Data acquisition system for pressurized pipeline system were designed md fabricated to obtain high frequency pressure data. The methodology properly handles the unavoidable uncertainties in measurement and modeling error. Based on information from head pressure test data, it provides leak prediction capability from the transient events with leakage.

Real-time optimal pump operation model development (경제적인 용수공급을 위한 실시간 송수펌프의 최적운영 모형 개발)

  • Kim, Kang Min;Choi, Jeong Wook;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.185-185
    • /
    • 2016
  • 일반적인 송 배수시스템의 운영은 지대가 높은 곳에 위치한 배수지(tank)에 용수를 저장한 후, 자연유하에 의해 수요절점으로 용수를 공급한다. 이때 배수지에 용수를 송수하기 위한 펌프장 운영에서 많은 전기에너지가 소모된다. 일반적으로 송수펌프의 운영은 다년간의 운영자료를 기반으로 운영자의 판단에 의해 이루어지거나, SCADA(Supervisory Control and Data Acquisition)시스템을 통해 관측되는 배수지 수위를 기준으로 펌프 작동여부를 결정하고 있다. 본 연구에서는 이러한 기존 펌프운영방법을 개선하고 좀 더 효율적인 운영방법을 모색하기 위해 실시간 송수펌프 최적운영 모형을 개발하였다. 최적화 기법으로는 유전자 알고리즘(genetic algorithm)을 사용하였으며, 다양한 제약조건(operational constraints)을 적용하고 급수지역의 24시간 용수사용량을 미리 예측하여 실제 시스템의 운영형태와 근접하게 반영하였다. 또한 최적화 과정에서 상수관망해석 프로그램(EPANET)을 연계하여 수요절점의 수압조건 및 시스템의 운영상황을 모의하였다. 개발된 모형을 국내 P시의 광역상수도 시스템에 실제 적용하였으며, 현장 실시간 운영 데이터를 입수하여 전력사용량, 배수지수위, 이산화탄소 발생량 등을 비교, 분석하였다. 개발 모형을 이용하여 펌프운영을 실시하였을 경우, 기존의 운영방식과 비교하여 경제적/환경적으로 뚜렷한 개선 효과를 확인할 수 있었다.

  • PDF

Real-time Optimal Pump Operation for Water Transmission Network (송·배수시스템의 실시간 최적 펌프운영)

  • Kim, Kyung Wan;Choi, Jeong Wook;Kang, Doosun;Kim, Byug Seop;Kang, Min Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.158-158
    • /
    • 2015
  • 대부분의 대규모 배수지는 고지대에 위치함으로써 자연유하를 통해 배, 급수지역으로 용수를 공급한다. 이를 위해 배수지 전단에는 가압장이 위치하여 정수장에서 처리된 용수를 고지대에 위치한 배수지로 송수한다. 이때 가압장에서 발생하는 전력소비량이 매우 높은 것으로 알려져 있으며, 효율적인 펌프운영을 통해 상당한 전력비용 절감이 가능할 것으로 판단된다. 일반적인 가압장의 운영은 시스템 운영자의 경험을 토대로 해당 가압장에 연결된 배수지의 수위에 따라 펌프의 작동여부를 결정하는 방법이 주로 사용되고 있다. 이러한 운영방법은 용수공급의 안전성을 우선시함으로써 배수지의 수위를 일정하게 유지하고자 빈번하게 펌프를 작동하게 되고 따라서 가압장에서 소모되는 전력량이 커서 운영효율 측면에서는 바람직하지 않다고 할 수 있다. 또한 빈번한 펌프의 작동으로 인해 펌프의 수명이 단축될 뿐만 아니라, 배수지내 용수의 수질저하 문제도 발생할 수 있다. 본 연구에서는 효율적인 펌프장 운영을 위해 급수지역의 24시간 용수사용량을 예측하고, 그에 따른 펌프장의 가압 유량 및 양정을 파악하여 적정용량의 펌프를 선정하고 운영함으로써 펌프의 운영비용의 최소화 및 안정적인 용수공급을 동시에 달성하고자 한다. 이를 위해, 실시간 최적화 모형을 개발하였다. 개발된 최적화 모형은 상수관망해석 프로그램(EPAENT)을 연계하여 수요절점의 수압조건 및 운영상황을 모의하였다. 최적화 기법으로는 유전자알고리즘을 사용하였으며, 실제 시스템의 운영상황를 반영하기 위한 다양한 제약조건(operational constraints)을 적용하였다. 개발된 모형은 정속펌프(혹은 On/Off 펌프) 뿐만 아니라, 최근 실무에서 널리 사용되고 있는 변속펌프(variable speed pump)를 추가적으로 고려하였다. 개발된 모형은 국내에서 실제 운영되고 있는 송, 배수 시스템에 적용하여 모형의 실무 적용가능성을 검증하였다.