• Title/Summary/Keyword: 수송온도

Search Result 284, Processing Time 0.02 seconds

육계의 수송 및 계류 환경 조사 연구

  • Kim, Dong-Hun;Yu, Yeong-Mo;Jo, Su-Hyeon;Park, Beom-Yeong;Chae, Hyeon-Seok;An, Jong-Nam;Kim, Yong-Gon;Lee, Jong-Mun
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2004.10a
    • /
    • pp.288-290
    • /
    • 2004
  • 이 연구는 국내에서의 육계수송 및 계류실태를 파악하여 이를 개선하기 위해 수행하였다. 수송차량 당 최고 80수가 폐사하였으며 수송밀도는 $242.6cm^2/kg$으로 비교적 양호하였다. 계류 시간은 평균 9시간 내외로 지나치게 길어 이에 대한 개선이 요구되었다. 수송 중의 온도는 트럭 적재함 위쪽에 위치한 어리장에서 가장 높았으며 운행과 정지에 관계없이 전체적으로 적정온도보다 크게 높았다. 계류장 온도 또한 적정온도 수준에 비해 높았으며 계류 중 물 뿌림은 온도를 낮추는 데에 효과적이었다.

  • PDF

Thermo-hydraulic Numerical Analysis for the Leakage of Buried District Heating Pipe (열수송관의 누수에 대한 열-수리적 수치해석)

  • Shin, Hosung;Hong, Seung-Seo
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.3
    • /
    • pp.17-26
    • /
    • 2022
  • Domestic district heating system needs safety management guidelines using the change of surface temperature to detect damages to buried heat pipes. This paper performed numerical analyses on the temperature change of ground surface due to the burial and leakage of heat pipes. Temperature difference between the ground surface above the buried heat pipes and the surrounding surface rises to a crescendo between 3 am and 8 am. It is more significant in winter rather than in summer. Low groundwater level magnifies the temperature increase of the ground surface by the heat pipe, which is smaller in the asphalt pavement than in the bare soil. Without leakage of the buried heat pipe, the temperature increment on the ground surface by the heat pipe is within 3.0℃ in the bare soil and 3.5℃ in the asphalt pavement. Leakage of the supply heat pipe in the bare soil increases the temperature on the ground surface gradually in the summer but rapidly in the winter. Asphalt pavement shows a lower increment and increasing rate of the temperature on the ground surface due to pipe leakage than bare soil surface. And leakage on both sides of the supply pipe takes 1-2 days for the temperature difference from the surrounding soil surface to reach 10℃.

Upheaval Buckling of Offshore Pipelines due to the Transportation of High Pressure and High Temperature Liquid (고온 고압의 유체 수송에 의한 해저 파이프의 수직 좌굴 현상)

  • Hyun-Mo Son;Si-Young Kim;Han-Suk Choi
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.52-57
    • /
    • 2002
  • 본 논문은 고온 고압의 유체를 수송하는 해저 파이프의 좌굴 현상에 대해서 논하였다. 고온 고압의 유체를 해저 파이프로 수송 할 때, 수송되는 고온 고압의 유체와 수위 해저의 온도와 압력들의 차에 의해서 유체 수송 파이프는 축 방향으로 압축력을 받게 되고 이 압축력을 견디지 못하면 수송 파이프는 수직 방향의 좌굴 현상이 발생하게 된다. 논문에서는 "semi-empirical design method"를 사용하여 수송 유체의 온도와 압력의 여러 가지 변화에 따라 파이프의 축 방향 압축력을 계산하고 수직 좌굴 현상에 따른 안전계수를 구하여 파이프의 초기 설계 결정에 도움을 주고자 했다.

Thermal Analysis for Dry Transport of a Shipping Cask (수송용기의 건식수송에 대한 열해석)

  • Lee, J.C.;Kang, H.Y.;Yoon, J.H.;Chung, S.H.;Kwack, E.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.248-254
    • /
    • 1993
  • The purpose of this study is to evaluate the thermal safety for dry transport of a shipping cask. Analysis condition was based on an ambient temperature of 38$^{\circ}C$ for normal heat condition. The cask was designed to carry 4PWR spent fuel assemblies with a burnup of 38,000 MWD/MTU and 3 years of cooling time. Thermal analysis was carried out by using the COBRA-SFS code. The fuel cavity was considered to be filled with air, nitrogen or helium gas for dry transport. The results of analysis showed that the maximum temperatures of fuel rod cladding in air and helium cavity would be 277$^{\circ}C$ and 226$^{\circ}C$, respectively, for 3 years of cooling time. These values were less than the specified temperature to maintain the thermal integrity of fuel assembly for dry transport.

  • PDF

Effect of Transportation Temperature and Treatment Time of Ethylene in the Simulated Export on Ripening and Quality of 'Cheongdobansi' Astringent Persimmon (떫은감 '청도반시' 모의 수출에서 수송 온도와 에틸렌 발생제 투입시기가 과실의 숙성 및 품질에 미치는 영향)

  • Kim, Ji-Young;Kim, Il-Ho;Nam, Hyun-Jin;Park, Young-Hoon;Kang, Jum-Soon;Choi, Young-Whan;Son, Beung-Gu;Lee, Yong-Jae
    • Journal of agriculture & life science
    • /
    • v.51 no.4
    • /
    • pp.79-86
    • /
    • 2017
  • We performed simulations of shipping conditions to export 'Cheongdobansi' astringent persimmon to tropical regions. We stored the fruits at $0^{\circ}C$, $5^{\circ}C$, or $10^{\circ}C$ temperature for 15 days to simulate the transport conditions, and then maintained the fruits at $30^{\circ}C$ for 5 days to simulate the distribution condition. Variables that we focused on are 1) the transport temperature($0^{\circ}C$, $5^{\circ}C$, or $10^{\circ}C$) and 2) the treatment time of ethylene generator(before or after shipping). We examined the ripening ratio and quality of the fruits at the end of the shipping and at that of the distribution. The examination at the end of the shipping showed that all of the fruits were ripened at $10^{\circ}C$ transportation but not ripened at $0^{\circ}C$ or $5^{\circ}C$ transportation in the ethylene treated condition. The untreated fruits were not ripened regardless of the transportation temperature. The examination at the end of the distribution showed that all of the fruits were ripened at $5^{\circ}C$ and $10^{\circ}C$ transportation, while 38.5% of fruits were ripened at $0^{\circ}C$ transportation in the ethylene treated fruits before shipping. The fruits treated after shipping were 63.5% and 59.6% ripened at $0^{\circ}C$ and $5^{\circ}C$ transportation, respectively. Unexpectively, only 19.2 % of fruits treated after shipping ripened at $10^{\circ}C$ transportation.

Expansion Analysis of Subsea Pipe-In-Pipe Due to High Temperature and High pressure Product (고온 고압 수송용 해저 이중배관의 팽창해석)

  • 최한석;손현모;김시영
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.56-60
    • /
    • 2002
  • 본 논문은 고온 고압의 유류 수송용 이중배관의 팽창에 대한 해석적 방법에 대한결과고찰과 해석, 그리고 설계시 응용이 가능한 현상에 대해 논하였다. 고온의 유류수송시 온도를 유지할 목적으로 내부의 수송 배관과 외부의 케이싱 배관사이에 절연체가 쓰여진다.이런 이중배관의 팽창을 조사할 수 있는 간단한 해석적 방법이 개발되었다. 본 논문에서는온도의 분포, 입력, 토질의 저항, 수송배관과 케이싱 배관과의 상호작용 등이 고려되어졌으며, 이 해석적 방법은 심해의 이중배관 해석에 적합하게 개발되었다. 계산의 결과 분석에서고온의 영향이 고압보다 현저한 것이 밝혀졌다.

KSC-28 사용후핵연료 수송용기의 열해석 평가

  • 이주찬;방경식;민덕기;도재범;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.268-273
    • /
    • 1997
  • 사용후핵연료는 장기간 강한 방사선과 붕괴열이 방출된다. 따라서 사용후핵연료를 안전하게 운반하기 위하여 수송용기는 방사선차폐의 건전성, 격납경계의 유지 및 내부 붕괴열의 적절한 제거 등의 설계기준을 만족하도록 설계되어야 한다. 본 연구에서는 28개의 PWR 사용후핵연료집합체를 운반할 수 있는 KSC-28 수송용기의 적절한 열전달 특성을 갖는 copper 냉각핀 및 aluminum 전열판을 설정하였다. 또한, 정상수송조건 및 화재사고조건에 대한 열전달해석을 수행하여 수송용기의 열적 건전성을 평가하였고 여기에서 얻어진 온도를 열하중으로 고려하여 열응력해석을 수행함으로써 수송용기의 온도변화에 따른 구조적 건전성을 평가하였다.

  • PDF

Numerical Analysis of the Non-Isothermal Heat Transfer in Solids Conveying Zone of a Single Screw Extruder (단축압출기 고체수송부에서의 비등온 열전달 현상에 관한 수치 해석)

  • Ahn Young-Cheol
    • Polymer(Korea)
    • /
    • v.29 no.6
    • /
    • pp.549-556
    • /
    • 2005
  • Effects of the dimensionless variables on the heat transport phenomena in the extrusion process of a single screw extruder have been studied numerically. Based on the understanding of the solids conveying related to the geometrical structure and characteristics of the screw, the heat balance equation for the solids conveying zone was established and normalized. The finite volume method and power-law scheme were applied to derive a discretized equation and the equation was solved using the alternating direction iterative method with relaxation. Effects of the dimensionless parameters, Biot and Peclet numbers, that define the heat transfer characteristics of the solids conveying zone have been investigated with respect to the temperature of the feeding zone and the length of the solids conveying zone. As the Biot number is increased, the heat loss by cooling dominates to decrease the temperature of the barrel but it has little effects on the temperature of the solids bed and the length of the solids conveying zone. On the other hand, if the Peclet number is increased, the convection term dominates to decrease the temperature of the solids bed and it results in an increase in the length of the solids conveying zone.

KSC-7 수송용기의 건식조건에 대한 열적 건전성 평가

  • 이주찬;방경식;이홍영;도재범;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.447-452
    • /
    • 1996
  • 본 연구에서는 7개의 PWR 사용후핵연료집합체를 운반할 수 있는 KSC-7 수송용기의 건식수송조건에 대한 열적 건전성을 평가하였다. 수송용기 축소모델을 제작하여 열시험을 수행하였고 또한, 시험조건과 동일한 조건으로 열전달해석을 수행하여 두가지 결과를 비교 분석함으로써 시험 및 해석결과에 대한 신뢰성을 검증하였다. 신뢰성이 검증된 해석방법을 이용하여 수송용기 본체 및 핵연료집합체에 대한 열전달해석을 수행함으로써 방사선차폐체 및 핵연료봉에 대한 열적 건전성을 입증하였다. 또한, 수송용기의 온도상승에 따른 구조적 건전성을 평가하기 위한 열응력해석을 수행하였다.

  • PDF

수송용기 Slice 모델에 의한 열전달시험

  • 방경식
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.339-343
    • /
    • 1995
  • PWR 사용후핵연료 집합체를 운반할 수 있는 수송용기를 개발하기 위하여 단면이 수송용기의 실제 크기인 slice 모델을 사용하여 법규에서 규정하고 있는 정상조건인 주변온도 38$^{\circ}C$에서 냉각 매체로 nitrogen 과 helium 인 경우에 대하여 열시험을 수행하여 수송용기의 열전달 특성 및 핵연료봉의 건전성을 평가하였다. 열시험결과 내부핵연봉의 최대 은도는 각각 448$^{\circ}C$ 와 416$^{\circ}C$로 측정되었다. 이 값들은 핵연료봉의 건전성 유지에 필요한 허용치 이내 만족하는 것으로 수송 용기의 열전달성능이 우수함을 입증하는 것이다.

  • PDF