• Title/Summary/Keyword: 수소전지

Search Result 1,288, Processing Time 0.033 seconds

Effects of Electrolyte Concentration on Growth of Dendritic Zinc in Aqueous Solutions (수용액중 아연 덴드라이트의 성장 반응에 미치는 전해질 농도의 영향)

  • Shin, Kyung-Hee;Jung, Kyu-Nam;Yoon, Su-Keun;Yeon, Sun-Hwa;Shim, Joon-Mok;Joen, Jae-Deok;Jin, Chang-Soo;Kim, Yang-Soo;Park, Kyoung-Soo;Jeong, Soon-Ki
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.4
    • /
    • pp.390-396
    • /
    • 2012
  • In order to understand the nature of dendritic zinc growth, electrochemical zinc redox reaction on nickel plate was investigated in aqueous solutions containing different concentrations, 0.2, 0.1 and 0.02 $mol{\cdot}dm^{-3}$ (M), of zinc sulfate ($ZnSO_4$) or zinc chloride ($ZnCl_2$). Zinc ion was efficiently reduced and oxidized on nickel in the high-concentration (0.2 M) solution, whereas relatively poor efficiency was obtained from the other low-concentration solutions (0,1 and 0.02 M). Cyclic voltammetry (CV) analysis revealed that the 0.2 M electrolyte solution decomposes at more positive potentials than the 0.1 and the 0.02 M solutions. These results suggested that the concentration of electrolyte solution and anion would be an important factor that suppresses the reaction of the zinc dendrite formation. Scanning Electron Microscopy (SEM) data revealed that the shape of dendritic zinc and its growing behavior were also influenced by electrolyte concentration.

a-SiGe:H 박막의 고상결정화에 따른 주요 결험 스핀밀도의 변화

  • 노옥환;윤원주;이정근
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.78-78
    • /
    • 2000
  • 다결정 실리콘-게르마늄 (poly-SiGe)은 태양전지 개발에 있어서 중요한 물질이다. 우리는 소량의 Ge(x=0.05)으로부터 다량의 Ge(x=0.67)을 함유한 수소화된 비정질 실리콘-게르마늄 (a-SiGe:H) 박막의 고상결정화 과정을 ESR (electron spin resonance)방법으로 조사해보았다. 먼저 PECVD 방법으로 Corning 1737 glass 위에 a-Si1-xGex:H 박막을 증착시켰다. 증착가스는 SiH4, GeH4 가스를 썼으며, 기판온도는 20$0^{\circ}C$, r.f. 전력은 3W, 증착시 가스압력은 0.6 Torr 정도이었다. 증착된 a-SiGe:H 박막은 $600^{\circ}C$ N2 분위기에서 다시 가열되어 고상결정화 되었고, 결정화 정도는 XRD (111) peak의 세기로부터 구해졌다. ESR 측정은 상온 x-band 영역에서 수행되었다. 측정된 ESR스팩트럼은 두 개의 Gaussian 함수로써 Si dangling-bond와 Ge dangling-bond 신호로 분리되었다. 가열 초기의 a-SiGe:H 박막 결함들의 스핀밀도의 증가는 수소 이탈에 기인하고, 또 고상결정화 과정에서 결정화된 정도와 Ge-db 스핀밀도의 변화는 서로 깊은 상관관계가 있음을 알 수 있었다. 특히 Ge 함유량이 큰 박막 (x=0.21, 0.67)에서 뿐만 아니라 소량의 Ge이 함유된 박막(x=0.05)에서도 Ge dangling-bond가 Si dangliong-bond 보다 고상결정화 과정에서 더 중요한 역할을 한다는 것을 알수 있었다. 또한 초기 열처리시 Si-H, Ge-H 결합에서 H의 이탈로 인하여 나타나는 Si-dangling bond, Ge-dangling bond 스핀밀도의 최대 증가 시간은 x 값에 의존하였는데 이러한 결과는 x값에 의존하는 Si-H, Ge-H 해리에너리지로 설명되어 질 수 있다. 층의 두께가 500 미만인 커패시터의 경우에 TiN과 Si3N4 의 계면에서 형성되는 슬릿형 공동(slit-like void)에 의해 커패시터의 유전특성이 파괴된다는 사실을 알게 되었으며, 이러한 슬릿형 공동은 제조 공정 중 재료에 따른 열팽창 계수와 탄성 계수 등의 차이에 의해 형성된 잔류응력 상태가 유전막을 기준으로 압축응력에서 인장 응력으로 바뀌는 분포에 기인하였다는 사실을 확인하였다.SiO2 막을 약화시켜 절연막의 두께가 두꺼워졌음에도 기존의 SiO2 절연막의 절연 파괴 전압 및 누설 전류오 비교되는 특성을 가졌다. 이중막을 구성하고 있는 안티퓨즈의 ON-저항이 단일막과 비교해 비슷한 것을 볼 수 잇는데, 그 이유는 TiO2에 포함된 Ti가 필라멘트에 포함되어 있어 필라멘트의 저항을 감소시켰기 때문으로 사료된다. 결국 이중막을 구성시 ON-저항 증가에 의한 속도 저하 요인은 없다고 할 수 있다. 5V의 절연파괴 시간을 측정한느 TDDB 테스트 결과 1.1$\times$103 year로 기대수치인 수십 년보다 높아 제안된 안티퓨즈의 신뢰성을 확보 할 수 있었다. 제안된 안티퓨즈의 이중 절연막의 두께는 250 이고 프로그래밍 전압은 9.0V이고, 약 65$\Omega$의 on 저항을 얻을수 있었다.보았다.다.다양한 기능을 가진 신소재 제조에 있다. 또한 경제적인 측면에서도 고부가 가치의 제품 개발에 따른 새로운 수요 창출과 수익률 향상, 기존의 기능성 안료를 나노(nano)화하여 나노 입자를 제조, 기존의 기능성 안료에 대한 비용 절감 효과등을 유도 할 수 있다. 역시 기술적인 측면에서도 특수소재 개발에 있어 최적의 나노 입자 제어기술 개발 및 나노입자를 기능성 소재로 사용하여 새로운 제품의 제조와 고압 기상 분사기술의 최적화에 의한 기능성 나노 입자 제조 기술을 확립하고 2차 오염 발생원인 유기계 항균제를 무기계 항균제로 대체할 수 있다. 이와 더불

  • PDF

Comparison of Membrane Degradation of PEMFC by Fenton Reaction and OCV Holding (Fenton 반응과 OCV Holding에 의한 PEMFC 고분자 전해질 막의 열화비교)

  • Oh, Sohyung;Kwag, Ahhyun;Lee, Daewoong;Lee, Mooseok;Lee, Donghoon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.768-773
    • /
    • 2019
  • The Fenton reaction, which evaluates the electrochemical durability of polymer membranes of polymer electrolyte fuel cells (PEMFC), and the degradation of polymer membranes by OCV holding method are compared. The Fenton reaction is a method that can evaluate the chemical durability of the polymer membrane at outside the cell in a shorter time than the OCV Holding method. The Fenton reaction was carried out at 30% hydrogen peroxide, 10 ppm iron, and $80^{\circ}C$ for 24 hours. OCV Holding was driven at $90^{\circ}C$, 30% relative humidity and OCV for 168 hours. The Fenton reaction caused a lot of degradation inside the polymer membrane. On the other hand, in OCV Holding, the membrane thickness was thinned by the entire surface and internal degradation. The fluorine emission rate was more than 10 times higher than that of OCV Holding due to the Fenton reaction. The hydrogen permeation rate increased about 30% at 24 hours of Fenton reaction. At OCV Holding, hydrogen permeability decreased after 24 hours and then increased. As a whole, there was a difference in a membranes deteriorated by Fenton reaction and OCV Holding.

Effects of Mixed Casting Solvents on Morphology and Characteristics of Sulfonated Poly(aryl ether sulfone) Membranes for DMFC Applications (직접 메탄올 연료전지용 술폰화 폴리아릴에테르술폰 전해질 막의 혼합 캐스팅 용매에 따른 형태 및 특성)

  • Hong, Young-Taik;Park, Ji-Young;Choi, Jun-Kyu;Choi, Kuk-Jong;Hwang, Taek-Sung;Kim, Hyung-Joong
    • Membrane Journal
    • /
    • v.18 no.4
    • /
    • pp.282-293
    • /
    • 2008
  • Partially sulfonated poly(aryl ether sulfone) membranes were prepared from the sulfonated sulfone monomer, which was synthesized by a nucleophilic substitution, non-sulfonated monomers and potassium carbonate by a direct polymerization method and a subsequent solution casting technique with mixed solvents of N-methyl-2-pyrrolidone (NMP) and dimethylacetamide (DMAc). To investigate the effect of mixed solvent, the volume ratios of NMP and DMAc were varied in the range of $0{\sim}100%$ and the degrees of sulfonation of the copolymers were fixed as 50%. The surface properties of the resulting membranes were examined by scanning electron microscope (SEM) and atomic force microscope (AFM), and a comparative study of the morphology changes and the physicochemical properties such as proton conductivity and methanol permeability was achieved. It was found that proton conductivities depend on the volume ratio of NMP-DMAc mixed solvents, and the proton conductivity determined at the condition of $25^{\circ}C$ and 100% relative humidity was $1.38{\times}10^{-1}\;S/cm$ for the membrane prepared in the 50:50 v/v-% of NMP : DMAc mixed solvent.

Poly(arylene ether ketone) block copolymer prepared through sulfonation process for polymer electrolyte membrane fuel cell (술폰화 공정을 통해 제조한 고분자 전해질형 연료전지용 폴리(아릴렌 이서 케톤) 블록 코폴리머)

  • Jang, Hyeri;Nahm, Keesuk;Yoo, Dongjin
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.66-72
    • /
    • 2016
  • In this study, a sulfonated poly(arylene ether ketone) block copolymer was prepared from hydrophilic oligomer and hydrophobic oligomer. The structure of the prepared membrane was characterized by $^1H$-NMR, FT-IR and GPC. The $M_w$(weight-average molecular weights) of the polymer was $209,700g\;mol^{-1}$ and the molecular weight distribution($M_w/M_n$) of 1.25 was obtained. The prepared membrane showed excellent thermal stability with gradual weight loss up to $200^{\circ}C$. The proton conductivity of SPAEK block copolymer reached the maximum of $9.0mS\;cm^{-1}$ at $90^{\circ}C$ under 100% relative humidity (RH). From the observed results, it is necessary to do more aggressive attempt to study the possibility of application as an ion-conductive composite electrolyte.

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

Effect of Current Density on Ion Conductivity of Membrane in Proton Exchange Membrane (고분자전해질 연료전지에서 고분자막의 이온전도도에 미치는 전류밀도의 영향)

  • Hwang, Byungchan;Oh, Sohyung;Lee, Daewoong;Chung, Hoi-Bum;You, Seung-Eul;Ku, Young-Mo;Na, Il-Chae;Lee, Jung-Hoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • In this work, we study the ion conductivity by analyzing the impedance to the high current density range that the PEMFC (Proton Exchange Membrane Fuel Cell) is actually operated. The effect of GDL (Gas Diffusion Layer)presence on impedance was investigated indirectly by measuring hydrogen permeability. When the RH (Relative Humidity)was higher than 60% in the low current range (< $80mA/cm^2$), the moisture content of the polymer membrane was sufficient and the ion conductivity of the membrane was not influenced by the current change. However, when RH was low, ion conductivity increased due to water production as current density increased. The ion conductivity of the membrane obtained by HFR (High Frequency Resistance) in the high current region ($100{\sim}800mA/cm^2$)was compared with the measured value and simulated value. At RH 100%, both experimental and simulated values showed constant ion conductivity without being influenced by current change. At 30~70% of RH, the ionic conductivity increased with increasing current density and tended to be constant.

Organic-inorganic Nanocomposite Adhesive with Improved Barrier Property to Water Vapor for Backsheets of Photovoltaic Modules (태양광모듈용 저가형 백시트 제조를 위한 고수분차단성 유무기 나노복합형 접착제)

  • Hwang, Jin Pyo;Lee, Chang Hyun
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.530-537
    • /
    • 2015
  • Photovoltaic (PV) modules are environmentally energy conversion devices to generate electricity via photovoltaic effect of semiconductors from solar energy. One of key elements in PV modules is "Backsheet," a multilayered barrier film, which determines their lifetime and energy conversion efficiency. The representative Backsheet is composed of chemically resistant poly(vinyl fluoride) (PVF) and cheap poly(ethylene terephthalate) (PET) films used as core and skin materials, respectively. PVF film is too expensive to satisfy the market requirements to Backsheet materials with production cost as low as possible. The promising alternatives to PVF-based Backsheet are hydrocarbon Backsheets employing semi-crystalline PET films instead of PVF film. It is, however, necessary to provide improved barrier property to water vapor to the PET films, since PET films are suffering from hydrolytic decomposition. In this study, a polyurethane adhesive with reduced water vapor permeation behavior is developed via a homogeneous distribution of hydrophobic silica nanoparticles. The modified adhesive is expected to retard the hydrolysis of PET films located in the core and inner skin. To clarify the efficacy of the proposed concept, the mechanical properties and electrochemical PV performances of the Backsheet are compared with those of a Backsheet employing the polyurethane adhesive without the silica nanoparticles, after the exposure under standard temperature and humidity conditions.

Experimental study on heating performance characteristics of electric heat pump system using stack coolant in a fuel cell electric vehicle (연료전지 스택 폐열 활용 전동식 히트펌프 시스템 난방 성능 특성 연구)

  • Lee, Ho-Seong;Kim, Jung-Il;Won, Hun-Joo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.924-930
    • /
    • 2018
  • The objective of this study was to investigate heating performance characteristics of electric heat pump system in a fuel cell electric vehicle (FCEV). In order to analyze heating performance characteristics of electric heat pump system with plate-type heat exchanger using stack coolant to evaporate the refrigerant, R-134a, each component was installed and tested under various operating conditions, such as air inlet temperature of inner condenser and compressor speed. When the air inlet temperature of inner condenser was varied from $0.0^{\circ}C$ to $-20.0^{\circ}C$, heating capacity was not quite different due to similar temperature gap between inlet and outlet of inner condenser with electric-driven expansion valve (EEV). However, COP increased until certain EEV opening, especially under 45.0%, because of decreasing power consumption. According to the compressor speed variation from 2,000 to 4,000 RPM, heating capacity and COP were found to have opposite trend. In the future works, stack coolant conditions as the heat source for tested heat pump system were analyzed with respect to heating performance, such as heating capacity and COP.

Study on the Platinum Deposition in Membrane of Polymer Electrolyte Membrane Fuel Cell during Electrode Degradation Process (고분자전해질 연료전지의 전극 열화 과정에서 고분자막에 석출된 백금에 관한 연구)

  • Oh, Sohyeong;Gwon, Hyejin;Yoo, Donggeun;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.202-207
    • /
    • 2022
  • The study on electrode degradation of Proton Exchange Membrane Fuel Cell (PEMFC) was mainly studied on the particle growth and active area reduction of Pt on the electrode. The degradation of the electrode catalyst Pt in contact with the membrane affects the deterioration of the polymer membrane, but there are not many studies related to this. In this study, the phenomenon of the deposition of deteriorated Pt inside the polymer membrane during the accelerated electrode catalyst degradation test and its effects were studied. The voltage change (0.6 V ↔ 0.9 V) was repeated up to 30,000 cycles to accelerate the platinum degradation rate. When the voltage change cycle was repeated while oxygen was introduced into the cathode, the amount of Pt deposited inside the film was larger than when nitrogen was introduced. As the number of voltage change cycles increased, the amount of Pt deposited inside the membrane increased, and Pt dissolved in the cathode moved toward the anode, showing a uniform distribution throughout the membrane at 20,000 cycles. In the process of the accelerated electrode catalyst degradation test, the hydrogen crossover current density of the membrane did not change, and it was confirmed that the deposited Pt did not affect the durability of the membrane.