Research Trends on Developments of High-performance Perfluorinated Sulfonic Acid-based Polymer Electrolyte Membranes for Polymer Electrolyte Membrane Fuel Cell Applications (고분자 전해질 막 연료전지 응용을 위한 고성능 과불소화계 전해질 막 개발 연구 동향)

  • Choi, Chanhee;Hwang, Seansoo;Kim, Kihyun
    • Membrane Journal
    • /
    • v.32 no.5
    • /
    • pp.292-303
    • /
    • 2022
  • An eco-friendly energy conversion device without the emission of pollutants has gained much attention due to the rapid use of fossil fuels inducing carbon dioxide emissions ever since the first industrial revolution in the 18th century. Polymer electrolyte membrane fuel cells (PEMFCs) that can produce water during the reaction without the emission of carbon dioxide are promising devices for automotive and residential applications. As a key component of PEMFCs, polymer electrolyte membranes (PEMs) need to have high proton conductivity and physicochemical stability during the operation. Currently, perfluorinated sulfonic acid-based PEMs (PFSA-PEMs) have been commercialized and utilized in PEMFC systems. Although the PFSA-PEMs are found to meet these criteria, there is an ongoing need to improve these further, to be useful in practical PEMFC operation. In addition, the well-known drawbacks of PFSA-PEMs including low glass transition temperature and high gas crossover need to be improved. Therefore, this review focused on recent trends in the development of high-performance PFSA-PEMs in three different ways. First, control of the side chain of PFSA copolymers can effectively improve the proton conductivity and thermal stability by increasing the ion exchange capacity and polymer crystallinity. Second, the development of composite-type PFSA-PEMs is an effective way to improve proton conductivity and physical stability by incorporating organic/inorganic additives. Finally, the incorporation of porous substrates is also a promising way to develop a thin pore-filling membrane showing low membrane resistance and outstanding durability.

Physical Properties and Sulfur Absorption Capacity of Spray-dried Solid Sorbents for Desulfurization of Syngas (합성가스 중 $H_2S$ 정제용 탈황제의 물성 및 반응특성)

  • Baek, Jeom-In;Lee, Joong-Beom;Kim, Ji-Woong;Eom, Tae-Hyoung;Ryu, Jeong-Ho;Jeon, Won-Sik;Ryu, Chong-Kul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.880-883
    • /
    • 2009
  • 석탄가스화복합발전(IGCC) 시스템에서 합성가스 중에 포함된 황화수소($H_2S$)는 후단의 가스 터빈과 같은 장치의 부식을 방지하고, 합성가스를 이용하는 연료전지 등의 연계 공정에서 요구하는 수준에 맞추어 정제되어야 한다. 본 연구에서는 $H_2S$ 정제공정 추가에 따른 IGCC 시스템의 효율저하를 최소화하기 위하여 고온고압에서 사용가능한 탈황제를 분무건조법을 이용하여 제조하고 제조된 탈황제에 대해 물성 및 황 흡수능 시험을 실시하였다. 형상, 내마모도, 평균입자크기, 충진밀도와 함께 제조된 탈황제가 적용되는 유동층 공정에 적합한 강도를 보유하는지 여부를 미국표준시험방법에 의하여 측정하였다. 황 흡수능은 열중량분석기를 반응기로 사용하여 모사 합성 가스 분위기에서 측정하였다. 분무건조 성형된 탈황제의 일부가 구형이 아닌 타원형 또는 도넛 형태를 나타내고 있어 형상 개선을 위한 제조방법 개선이 필요한 것으로 나타났다. 제조된 탈황제는 기공도가 65% 이상으로 macropore가 기공부피의 대부분을, mesopore가 비표면적의 대부분을 제공하고 있었다. 소성온도를 650 $^{\circ}C$에서 750 $^{\circ}C$로 증가시킴에 따라 대체로 강도가 감소하는 경향을 나타내었다. 열중량분석기로 측정된 황 흡수능은 약 10 wt%로 나타났다. 제조된 탈황제 중 일부는 유동층 공정에 적합한 물성을 보유하고 있었으며 반응성 또한 기존에 개발된 탈황제에 버금가는 성능을 나타내어 향후 공정 적용이 가능할 것으로 분석되었다.

  • PDF

Hydrogen Production for PEMFC Application in Plasma Reforming System (PEMFC용 플라즈마 개질 시스템의 수소 생산)

  • Yang, Yoon Cheol;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.1002-1007
    • /
    • 2008
  • The purpose of this paper studied the optimal hydrogen production condition of plasma reforming system to operate the PEMFC. Plasma reforming reactor used with Ni catalyst reactor at the same time, So $H_2$ concentration increased. Also the WGS and PrOx reactor were designed to remove CO concentration under 10 ppm, because CO has effect on catalyst poisoning of PEMFC. The maximum $H_2$ production condition in plasma reforming system was S/C ratio 3.2, $CH_4$ flow rate 2.0 L/min, catalytic reactor temperature $700{\pm}5^{\circ}C$ and input power 900 W. At this time, the concentration of produced syngas was $H_2$ 70.2%, CO 7.5%, $CO_2$ 16.2%,$CH_4$ 1.8%. The hydrogen yield, hydrogen selectivity and $CH_4$ conversion rate were 56.8%, 38.1% and 92.2% respectively. The energy efficiency and specific energy requirement were 37.0%, 183.6 kJ/mol. In additional, The experiment of $CO_2/CH_4$ ratio proceeded. Also WGS reactor experiment was proceeding on optimum condition of plasma reactor and the exit concentration were $H_2$ 68%, CO 337 ppm, $CO_2$ 24.0%, $CH_4$ 2.2%, $C_2H_4$ 0.4%, $C_2H_6$ 4.1%. At this time, experiment result of PrOx reactor were $H_2$ 51.9%, CO 0%, $CO_2$ 17.3%.

Parametric Study of SOFC System Efficiency Under Operation Conditions of Butane Reformer (부탄 개질기 운전조건에 따른 SOFC 시스템 효율에 대한 연구)

  • Kim, Sun-Young;Baek, Seung-Whan;Bae, Gyu-Jong;Bae, Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.341-347
    • /
    • 2010
  • In this study, the efficiency of a solid-oxide fuel cell (SOFC) system with a steam reformer or prereformer was analyzed under various conditions. The main components of the system are the reformer, SOFC, and water boiling heat recovery system. Endothermic and exothermic reactions occur in the reformer and SOFC, respectively. Hence, the thermal management of the SOFC system greatly influences the SOFC system efficiency. First, the efficiencies of SOFC systems with a steam reformer and a prereformer are compared. The system with the prereformer was more efficient than the one with steam reformer due to less heat loss. Second, the system efficiencies under various prereformer operating conditions were analyzed. The system efficiency was a function of the heat requirement of the system. The efficiency increased with an increase in the operating temperature of the prereformer, and the maximum system efficiency was observed at $450^{\circ}C$ for a S/C of 2.0.

Recent Research Trends of Catalytic Conversion of CO2 to High-value Chemicals (촉매 전환을 이용한 이산화탄소의 고부가 가치제품 생산에 대한 최근 연구 동향)

  • Song, Ki-Hun;Ryu, Jun-hyung;Chung, Jong-Sik
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.519-530
    • /
    • 2009
  • Reducing the emission of carbon dioxide, which is the main contributor to the green house effect, is becoming a global hot issue. Great attention has been thus given to utilization of carbon dioxide rather than just capturing and isolating it because it could convert carbon dioxide to high-value chemicals. In this paper, recent research trends are investigated on the catalytic conversion of carbon dioxide to syngas in the context of $CH_4$, dry-reforming, trireforming, and the electro-catalytic conversion of carbon dioxide through SOFC(Solid Oxide Fuel Cell) system. Research trends for utilizing syngas to high-value-added useful products, mainly fuel such as DME(Dimethyl Ether) are also discussed.

Study on Development of the Isolation Resistance Measurement System for Hydrogen Fuel Cell Vehicle (수소연료전지자동차용 절연저항 측정시스템 개발에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Moon, Hyun-Wook;Kim, Hyang-Kon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1068-1072
    • /
    • 2011
  • Hydrogen Fuel Cell Vehicle(HFCV) is system that uses electrical energy of fuel cell stack to main power source, which is different system with other vehicles that use high-voltage, large-current. Isolation performance of this system which is connected with electrical fire and electrical shock is important point. Isolation resistance of electric installation is divided according to working voltage, it follows criterion more than $100{\Omega}$/VDC (or $500{\Omega}$/VAC) about system operation voltage in a hydrogen fuel cell vehicle. Although measurement of isolation resistance in a hydrogen fuel cell vehicle is two methods, it uses mainly measurement by megger. However, the present isolation resistance measurement system that is optimized to use in electrical facilities is unsuitable for isolation performance estimation of a hydrogen fuel cell vehicle because of limit of maximum short current and difference of measurement resolution. Therefore, this research developed the isolation resistance measurement system so that may be suitable in isolation performance estimation of a hydrogen fuel cell vehicle, verified isolation performance about known resistance by performance verification of laboratory level about developed system, and executed performance verification through comparing results of developed system by performance verification of vehicle level with ones of existing megger. Developed system is judged to aid estimation and upgrade of isolation performance in a hydrogen fuel cell vehicle hereafter.

Research on evaluation technique concerning electrical safety for electrical shock protection of HFCV(Hydrogen Fuel Cell Vehicle) (HFCV의 감전보호를 위한 전기안전 평가기법에 관한 연구)

  • Lee, Ki-Yeon;Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Yu, Byeong-Yeol;Park, Yong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.200-202
    • /
    • 2009
  • 본 논문에서는 수소연료전지자동차의 고전압 시스템에서 직 간접접촉에 의한 인체 감전사고를 방지하기 위한 전기안전 평가기법인 절연저항과 전기적연속성 등에 대하여 분석하였다. ISO, UNECE, Japan Attachment 등의 외국 규격에서는 감전보호를 위한 평가 기준을 제시하고 있지만 세부적인 평가방법에 대해서는 명확하게 규정하고 있지 않기 때문에 전기안전 평가를 위한 측정방법 및 측정장비에 대한 최소한의 기준 정립이 필요한 실정이다. 따라서 본 연구에서는 전기안전 평가기법에 대한 HFCV 실차 상태의 실험을 통하여 나타난 문제점 분석을 통하여 감전보호를 위한 전기안전 평가기법 중 전기적 연속성 및 절연저항에 대한 측정방법과 측정장비의 사양에 대하여 제시하고자 한다.

  • PDF

Computational Fluid Dynamic Modeling for Internal Antenna Type Inductively Coupled Plasma Systems (CFD를 이용한 내장형 안테나 유도 결합 플라즈마 시스템 모델링)

  • Joo, Jung-Hoon
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.164-175
    • /
    • 2009
  • CFD is used to analyze gas flow characteristics, power absorption, electron temperature, electron density and chemical species profile of an internal antenna type inductively coupled plasma system. An optimized grid generation technology is used for a complex real-scale models for industry. A bare metal antenna shows concentrated power absorption around rf a feeding line. Skin depth of power absorption for a system is modeled to 50 mm, which is reported 53 mm by experiments. For an application of bipolar plates for hydrogen fuel cells, multi-sheet loading ICP nitriding system is proposed using an internal ICP antenna. It shows higher atomic nitrogen density than reported simple pulsed dc nitriding systems. Minimum gap between sheets for uniform nitriding is modeled to be 39 mm.

Performance Characteristics of the Electrical Air Conditioning System for the Zero Emission Passenger Vehicle (무공해 승용 자동차의 냉방을 위한 전동식 냉방시스템 성능에 관한 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5430-5437
    • /
    • 2011
  • The objective of this study is to investigate the cooling performances of the electrical air-conditioning system using electric driven scroll compressor for zero emission passenger vehicles. This air conditioner with air source was used R-134a as a refrigerant and installed in a real zero emission passenger vehicle for tests under various driving conditions. The cooling performance of the electrical air conditioner was affected by driving velocities and conditions of the tested vehicle. The condensing rate of the condenser during driving is better than that of the idle condition. The average cool down temperature in the cabin room decreased on average $5.2^{\circ}C$ with the increase of the outdoor temperature from $20.0^{\circ}C$ to $30.0^{\circ}C$. In addition, the cooling performances were sufficient for cooling loads of the tested passenger car under tested conditions.

Environmental Life Cycle Assessment (LCA) of Polymer Electrolyte Membrane Fuel Cell (PEMFC) System (Polymer Electrolyte Membrane Fuel Cell 시스템의 환경 전과정평가)

  • KIM, HYOUNGSEOK;HONG, SEOKJIN;HUR, TAK
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.1
    • /
    • pp.111-116
    • /
    • 2018
  • The environmental impacts of a 1 kW polymer electrolyte membrane fuel cell (PEMFC) system are quantitatively assessed by performing a Life Cycle Assessment (LCA) study. A PEMFC system produces electricity and heat simultaneously, so an appropriate allocation of associated inputs and outputs is performed between the electricity and heat produced. The environmental impacts of the PEMFC system on the impact categories such as global warming (GW), abiotic depletion (AD), acidification (AC), and eutrophication (EU) are assessed from the life cycle impact assessment. The impact indicator results of the impact assessment on these impact categories are obtained as $3.70E-01kg\;CO_2\;eq./kWh$, 1.86E-03 kg Sb eq./kWh, $4.09E-04kg\;SO_2\;eq./kWh$, and $1.88E-05kg\;PO_4{^{3-}}/kWh$, respectively. For all impact categories studied the most influential stage is the operation stage, which accounts for 98.8%, 98.7%, 70.3%, and 62.3% of the total impact on GW, AD, AC, and EU, respectively. For the impact categories of AD, AC, and EU, most of the environmental impacts during the operation stage is attributed to the production of city gas. However, for the impact category of GW, $CO_2$ emission from the reforming process of city gas is the main reason for the largest contribution of the operation stage to the total impact results.