• Title/Summary/Keyword: 수복재료

Search Result 321, Processing Time 0.035 seconds

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.

SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING (치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과)

  • Kim, Min-Jeong;Lee, Mi-Jeong;Yu, Mi-Kyung;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The purpose of this study was to compare the effect of surface sealing materials on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 after applying Single Bond. Following 7 days storage in distilled water at $37^{\circ}C$, the restorations were sealed as following systems : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. Then, toothbrush abrasion test was conducted using a wear testing machine. Surface roughness was measured by means of profilometer before and after toothbrushing and the results were statistically analysed by using a paired t-test and ANOVA. The bonded interfaces and the changes of surface roughness were examined by SEM. For microleakage test, specimens were stained in a $2\%$ methylene blue solution, then longitudinally sectioned and analyzed for leakage at occlusal and cervical interfaces using stereomicroscope. The results were statistically analysed by using a Kruskal-Wallis and Mann-Whitney U test. Surface roughness was increasing in all groups after toothbrushing, but no statistically significant differences. In SEM observation, surface sealant was partially retained and partially detached in bonded interfaces. Especially, microgap was identified in cervical margins. In microleakage test, there was better seal in the enamel region and a significant difference between groups at occlusal margin. Control group and Single Bond group had significantly better marginal seal at enamel margin than cervical margin.

The study of fractural behavior of repaired composite (수리된 복합 레진 수복물의 파괴 거동에 관한 연구)

  • Park, Sang-Soon;Nam, Wook;Eom, Ah-Hyang;Kim, Duck-Su;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.461-472
    • /
    • 2010
  • Objectives: This study evaluated microtensile bond strength (${\mu}TBS$) and short-rod fracture toughness to explain fractural behavior of repaired composite restorations according to different surface treatments. Materials and Methods: Thirty composite blocks for ${\mu}TBS$ test and sixty short-rod specimens for fracture toughness test were fabricated and were allocated to 3 groups according to the combination of surface treatment (none-treated, sand blasting, bur roughening). Each group was repaired immediately and 2 weeks later. Twenty-four hours later from repair, ${\mu}TBS$ and fracture toughness test were conducted. Mean values analyzed with two-way ANOVA / Tukey's B test ($\alpha$= 0.05) and correlation analysis was done between ${\mu}TBS$ and fracture toughness. FE-SEM was employed on fractured surface to examine the crack propagation. Results: The fresh composite resin showed higher ${\mu}TBS$ than the aged composite resin (p < 0.001). Mechanically treated groups showed higher bond strength than non-mechanically treated groups except none-treated fresh group in ${\mu}TBS$ (p < 0.05). The fracture toughness value of mechanically treated surface was higher than that of non-mechanically treated surface (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. Specimens having high KIC showed toughening mechanism including crack deviation, microcracks and crack bridging in FE-SEM. Conclusions: Surface treatment by mechanical interlock is more important for effective composite repair, and the fracture toughness test could be used as an appropriate tool to examine the fractural behavior of the repaired composite with microtensile bond strength.

The Effect of 15% Carbamide Peroxide on the Surface Roughness and Staining of Esthetic Restoratives (15% Carbamide Peroxide가 심미수복재의 표면조도와 착색에 미치는 영향)

  • Kim, Soo-Hwa;Choi, Hye-Sook;Roh, Jj-Yeon;Kim, Kwang-Mahn
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study was to evaluate the surface change after 15% carbamide peroxide home bleaching to various restorative materials (composite resin [CR], resin modified glass ionomer [RMGI] and glass ionomer [GI]) and to observe the effect of surface condition of the materials on re-staining. Three esthetic restorative materials (Filtek Z250, 3M, USA; Fuji II LC, GC, Japan; Fuji II, GC, Japan) were used in this study. Twenty specimens per material group were made and divided into two groups (bleached and control). The specimens were immersed in coffee after applying bleaching agent. The color change and surface roughness were measured before and after bleaching and after immersion in coffee. The data were analyzed with SPSS 18.0. The results were as follows: 1. The color of all experiment groups was significantly changed after bleaching (p<0.05). RMGI was the greatest value of ${\Delta}E^*$ and ${\Delta}L^*$. GI and CR groups were in ordering (p<0.05). The ${\Delta}a^*$ value was decreased GI, RMGI and CR. RMGI was only significantly decreased in ${\Delta}b^*$ value (p<0.05). 2. The surface roughness before and after bleaching was significantly different on CR, RMGI and GI (p<0.05). 3. After staining with coffee, the value of ${\Delta}E^*$ was increased in GI, RMGI and CR, furthermore GI and RMGI showed significant difference in the bleaching groups (p<0.05). The ${\Delta}L^*$ value of GI and RMGI was significantly decreased. 4. The change of surface roughness after staining was not significantly different in all groups (p>0.05). The maintenance of color stability in esthetic restorations is one of the most important properties. Tooth whitening is for the aesthetic. Therefore, dental professionals should notice to patients about re-staining after tooth whitening. They should give an instruction that how to prevent and which kinds of agents could be stained.

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.

Flexural strength and reliability of highly translucent colored zirconia (고반투명 유색 지르코니아의 굽힘강도와 신뢰도에 대한 연구)

  • Kong, Hyun-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.41-47
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the flexural strength and reliability of highly translucent colored zirconia for all ceramic restoration. Materials and Methods: Bar-shaped specimens (25 × 4 × 2.5 mm) were prepared from highly translucent monolithic zirconia. Three experimental groups were set up according to color (shade A0, A1, and A3). For each group, 20 specimens were prepared. Flexural strength was determined using a 3-point flexural test and results were analyzed with one-way ANOVA test. Weibull statistical analysis provided 2 parameter estimates: Weibull modulus and characteristic strength. X-ray diffraction (XRD) analysis was performed. Results: There was statistically significant difference between uncolored (Shade A0) and colored (shade A1 and A3) (P < 0.05), but there was no difference between colored groups (P > 0.05). The uncolored group had higher reliability compared with colored study groups. On x-ray diffraction analysis of each group, typical peaks of tetragonal phase appeared in all groups. Conclusion: Within the limitations of this in vitro study, coloring highly translucent zirconia had significant effect on flexural strength and reliability. Therefore, clinicians should be careful when using highly translucent colored zirconia to prevent breakage of veneering ceramic and enhance aesthetics.

A STUDY ON CHANGE OF COMPRESSIVE STRENGTH AND FLEXURAL STRENGTH OF DENTAL COMPOSITE RESIN AFTER WATER STORAGE (치과용 콤포짓트 레진의 수분 흡수에 따른 압축강도와 굴곡강도의 변화에 관한 연구)

  • Jeong, Nae-Jeong;Kim, Jung-Wook;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.146-153
    • /
    • 2001
  • The difference of composition of composite resin may affect the mechanical properties of composite resin and the environment is important for the properties of materials. The composite resin restoration is always exposed to fluid in oral cavity and the composite resin matrix is able to absorb water, which is accompanied by some swelling of the composite The uptake of water by composites has been correlated with decreases in surface hardness and wear resistance. The purpose of this study was to investigate the effects of water storage in $37^{\circ}C$ distilled water after 7days, 30days, 60days, 120days on compressive strength and flexural strength of dental composite resin, Z-100(group 1) Spectrum(group 2), Clearfil AP-X(group 3), Pyramid(group 4), Heliomolar(group 5). The compressive and flexural strength were measured by instron machine. The following results were obtained: 1. There were significant reduction of compressive strength as water storage time increased, 7days, 30days, 60 days, 120days(p<0.05). 2. There were significant reduction of flexural strength as water storage time increased, 7days, 30days, 60days, 120days(p<0.05). 3. Group 1, 2, 3 -hybrid type showed higher compressive and flexural strength than group 5-microfine type which had lower filler contents.

  • PDF

EFFECT OF RESIN MONOMERS ON THE ACTIVITY OF CARIOGENIC BACTERIA (수종의 레진 모노머가 우식 유발성 세균의 활성에 미치는 영향)

  • Seo, Young-Ju;Kook, Joong-Ki;Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.247-255
    • /
    • 2004
  • The purpose of this study was to examine the effects of resin composite monomers (Bis-GMA, TEGDMA, EGDMA, UDMA, HEMA, Camphorquinone) on the growth of the two cariogenic bacteria, Streptococcus mutans and Streptococcus sobrinus. We obtained the following results : 1. The growth rate of S. mutans and S. sobrinus was decreased significantly in the group of all composite resin monomer at a concentration of 0.03mmo1/L(P<0.01). 2. The growth rate of S. mutars in the group of UDMA at a concentration of 0.01 mmol/L and the group of CQ at a concentration of 0.005 mmol/L, 0.01 mmol/L was decreased significantly compared to the control group(P<0.01). 3. The growth rate of S. sobrinus in the group of HEMA, UDMA at a concentration of 0.01 mmol/L and the group of CQ at a concentration of 0.005mmol/L. 0.01mmo1/L was decreased significantly compared to the control group (P<0.01). 4. The growth rate of S. sobrinus in the group of EGDMA at a concentration of 0.001, 0.01, 0.03mmo1/L was decreased significantly compared to the control group(P<0.01) and were showed to be statistically significant difference between experimental groups(P<0.01).

  • PDF

Dimensional Changes of Ceromer Crown by Water Absorption (치과용 심미수복재료 세로모에서 수분흡수와 체적 변화에 관한 연구)

  • Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.119-124
    • /
    • 2009
  • Statement of problem: The increasing demand for esthetic restorations has been required developing new materials for tooth colored restoration. Ceromer(Ceramic Optimized Polymer) has some advantages over porcelain, and has gained increasing popularity in restorative dentistry. However, there is little information on the dimensional changes in a clinical restoration in moist conditions. Purpose: This study examined the dimensional changes in Ceromer restorations with a clinical crown shape that were fabricated in a clinical manner. Material and methods: The crowns for the maxillary central incisor were fabricated with two Ceromers($BelleGlass^{(R)}$ and $Targis^{(R)}$) using a similar clinical restoration manufacturing technique. A total of twenty specimens were prepared and immersed in distilled water at room temperature to allow for water absorption. The weight, height and width were measured at 24, 72 and 168 hours. The accumulated ratios of the changes were calculated and evaluated using a paired t-test and an independent independent t-test. Results: The dimensions and weight increased with increasing soaking time. $Targis^{(R)}$ showed significant differences in height and weight between 24 hours and the other times(P<.05). $BelleGlass^{(R)}$ showed significant differences in width and weight between 24 hours and the other times. The two materials showed different changing patterns of the dimensions but there were no statistically significant differences between them. Conclusion: The dimensions and weight of the Ceromer restorations were changed by water absorption. The clinical crown shaped specimen showed more complicated dimensional changes than the simplified specimens.

A study on the debate on traditional technique for Architectural Heritage conservation - Focusing on the dispute over the application of traditional technique for the restoration of the Sungnyemun gate - (건축문화유산 보존과 관련된 전통기술 논의 고찰 - 숭례문 복구에 있어서의 전통기술 적용 논란을 중심으로 -)

  • Kang, Hyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.3
    • /
    • pp.208-223
    • /
    • 2014
  • Since the recent restoration of the Sungnyemun gate (South gate of Seoul) which was burnt down in 2008, there were dispute about the application of traditional technique for the conservation of cultural heritage. In this research, the definition of traditional technique for cultural heritage conservation is thought and mentioned. In general, the understanding of traditional technique is based on the idea of 'tradition'. Tradition is not defined as a 'eternal doctrine existence', but a 'development of succession' and a 'living existence'. Thus 'traditional performance and craft as intangible cultural heritage' is defined as 'intangible' which also makes it difficult to define the 'original form/state' from 'the conservation of the original form' which is a major principle of cultural heritage. In case of Korea, if the 'traditional technique as intangible cultural heritage' is put into application to cultural heritage conservation, the unclear definition will cause many problems in the restoration/conservation site. This is because the site will apply this technique without any discussion of the range and limitation of 'traditional technique'. This means there will be the lack of discussion for the conservation of the cultural heritage which will not have a strict criteria for the allowable range of usage for the 'traditional material' using the vaguely defined 'traditional technique'. In this study, these application issues of the traditional technique were also considerecl, comparing the development of international wnservation principles. As a result, the conservation of 'traditional technique as intangible cultural heritage' is important, but the 'technique left inside the tangible cultural heritage' which is the 'material which is carrying the technique when it was firstly built' has more importance to preserve and need to be in the major considerations.