• Title/Summary/Keyword: 수명기간비용분석

Search Result 41, Processing Time 0.026 seconds

Cost-Benefit Analysis Method for Ageing Equipment of Chemical Plants Using Risk Assessment (위험성평가를 이용한 노후설비에 대한 비용 편익분석 방법)

  • Jung, Soomin;Jung, Changmo;Kang, Seok-Min;Chae, Seungbeen;Kang, Seung-Gyun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.84-92
    • /
    • 2020
  • Most facilities in chemical plants operate in environments that are outside the range of temperature and pressure that can be encountered on a daily basis, and are vulnerable to aging due to these stresses and environmental conditions. The facilities exposed to these conditions are not only likely to fail due to cumulative damage, but also lead to accidents if maintenance and replacement are not performed.Recommendation guidelines called risk-based inspection are widely used around the world-wide. However, limits exist for facilities that have already elapsed for a certain. As a result of the survey on the aging of Ulsan industrial complex in Korea, which carries out proper inspection, many of the facilities have been used for 20 years. Also, most of the facilities where the accident occurred have been in operation for more than 20 years. Therefore, this study suggested criteria for classifying devices that have exceeded a certain period of use as obsolete facilities. In addition, quantitative risk assessment was conducted. The safety investment method using the cost-benefit analysis method was proposed in order to calculate the loss cost and reduce the risk by expressing the risks of the corresponding aged facility as an Economic index. By utilizing the method of cost-benefit analysis of old facilities using the quantitative risk assessment presented in this study, it can be expected to improve the performance and life of old facilities, improve production efficiency and reliability of the system of facilities, change the recognition of safety management costs, increase employee stability, and reduce loss costs.

LCC Analysis of Steel Plate Bridge Deck Pavement Through Internalization of Improved Functions (기능 개선의 내재화를 통한 강상판 교면포장의 LCC 분석)

  • Baek, Jae Wook;Park, Tae Hyo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.113-123
    • /
    • 2011
  • LCC analysis is a method that coordinates with function evaluation for value improvement, rather than a separate one for cost evaluation. Although its accuracy is rising, materials and structural types developed or applied relatively recently have yet to obtain a sufficient maintenance profile DB, inducing reliability to reduce from difficulties in estimating maintenance records. Based on the above mentioned background, this paper presents the LCC methodology of coordinating functional intensification matters with cost for analysis on alternatives with difficulties in setting maintenance profile. Recently, steel plate bridge deck pavements are faced with problems such as plastic deformation due to the increase in heavy vehicles and traffic, promoting the development of a new compound pavement. This paper execute LCC analysis by mentioning case studies of SMA, Guss and PSMA pavements to include performance scale compared between alternatives as relative evaluation coefficients into the maintenance profile.

Reappraisal of Feed-In Tariffs of Electricity Generating from New and Renewable Energy Sources (신.재생에너지원 발전전력 차액지원을 위한 현행 기준가격의 재산정)

  • Kim, Eun-Il;Kim, Keon-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.281-286
    • /
    • 2008
  • Current feed-in tariffs(FIT) of Electricity generating from new and renewable energy sources are reappraised with the corrected formula of levelized generation cost(LGC) of utility power. The LGC of new and renewable electricity should be formulated in explicitly reflecting the capital cost and corporate tax during the economic life cycle based on its realistic application data. An applicable term of the FITs should, especially, be equal to the economic life cycle. The revised FITs issued in 2006 were, however, derived from the incorrect formula described in the study of KERI(Korea Electrotechnology Research Institute), and consequently misestimated. The reappraisal values for FIT of new and renewable electricity were shown and interpreted in this paper. An FIT of PV more than 30 kW, for example, should be 972.86 won/kWh instead of current 677.38 won/kWh increasing 43.6%. An upward revision of other FITs for new and renewable electricities should also be required in the range of 8.6% to 47.3%.

  • PDF

The Estimation of the Number of Spare Parts and the Changing Time about DSRC Road Side Equipment (단거리전용통신방식 노변기지국의 예비부품수 및 교체시기 산정)

  • Han, Dae-Hee;Lee, Chung-Won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.3
    • /
    • pp.174-182
    • /
    • 2007
  • There are not many studies on the maintenance and replacement for the ITS equipments. Most of ITS center has no comprehensive regulation on the equipment replacement. This study was focusing on estimation of equipment replacement period and the number of spare parts in stock using the actual failure data of Road Side Equipment (RSE) by Dedicated Short Range Communication (DSRC). The failure data showed a type of bath-tub curves. The data, however, did not fit to any probability distribution curve, which means that the preventive replacement cannot be strongly applied for the RSE. In the aspect of practical strategy, this study suggest that repairing cost and failure frequency be used for decision of replacement of RSE after the 1 or 2 year warrant period. The future study needs to include more RSE failure data as well as other equipments of the ITS.

  • PDF

A case study of life cycle cost analysis on high pressure sodium lamp and LED lamp for tunnel lighting (터널 조명 고압나트륨램프와 LED램프의 LCC 분석 사례 연구)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.5
    • /
    • pp.315-323
    • /
    • 2021
  • Tunnel is the most energy-consuming structure in road due to the characteristic of using artificial lighting during day and night. Therefore, tunnel lights are being replaced by LED lamp that have advantages with respect to low power consumption. The best use of social overhead capital can be expected by considering the life cycle cost, because to tunnel structures are accompanied by a series of medium-to-long-term and continuous processes of replacing auxiliary facilities. In this study, the saving effect by LCC analysis was quantitatively analyzed by replacing tunnel light sources from high-pressure sodium lamps to LED lamps. The effect of reducing the replacement cycle by increasing the life of the lamps and the resulting maintenance cost is very significant, on replacing tunnel lighting light sources with LED lamp.

RAM Modeling and Analysis of Earth Observation Constellation Satellites (지구관측 군집위성의 RAM 모델링 및 분석)

  • Hongrae Kim;Seong-keun Jeong;Hyun-Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.11-20
    • /
    • 2024
  • In the recent era of NewSpace, unlike high-reliability satellites of the past, low-reliability satellites are being developed and mass-produced at a lower cost to launch constellations satellites. To achieve cost-effective cluster satellite development, satellite users and developers need to assess the feasibility of maintaining mission performance over the expected lifespan when cluster satellites are launched. Plans for replacements due to random failures should also be established to maintain performance. This study proposed a method for assessing system reliability and availability to maintain mission performance and establish replacement strategies for Earth observation constellation satellites. In this study, a constellation reliability and availability model considering mission performance required for a satellite constellation, situations of satellite backup, and additional ground backups was established. The reliability model was structured based on the concept of a k-out-of-n system and the availability model used a Markov chain model. Based on the proposed reliability model, the minimum number of satellites required to meet mission requirements was defined and satellites needed in orbit during the required mission period to satisfy mission reliability were calculated. This research also analyzed the number of spare satellites in orbit and on the ground required to meet the desired availability during required service period through availability analysis.

A Study on the LCC Analysis of an Office Building HVAC System (오피스빌딩 냉난방시스템의 수명주기비용 분석에 관한 연구 : 흡수식 냉온수 유닛의 설치 유형을 중심으로 한 사례연구)

  • Park, Moon-Sun;Shin, Hyeong-Sik;Kim, Yong-Su
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.3 s.31
    • /
    • pp.112-121
    • /
    • 2006
  • The purpose of this study is to execute economical analysis for two types of office building HVAC system using LCC technique : single vs, separated HVAC(equal partition installation, unequal partition installation) system. The research method of this study includes the case analysis and questionnaire surveys. The results of this study are as follows: (1) LCCs of 3 types of HVAC system are estimated and the most economical one is investigated as single HVAC system, (2) In this case study, the single HVAC system was investigated as 34% lower in LCC during 15 years per $100m^2$ compared to equal partition installation, as 41% compared to unequal partition installation.

A Study on the Performance Prediction Model for Life Cycle Maintenance of Reservoir (저수지 생애주기 유지관리를 위한 성능저하예측 모델 연구)

  • Lee, Huseok;Kim, Ran-Ha;Cho, Choong-Yuen
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.568-574
    • /
    • 2021
  • According to the Framework Act on Sustainable Infrastructure Management, which has been enforced since 2020, reservoirs should be managed to minimize life cycle costs caused by aging through preemptive management such as systematic maintenance and performance improvement. For maintenance in consideration of the life cycle, it is essential to derive the end of life due to continuous performance degradation as the common period increases. For this purpose, it is necessary to develop a performance-predicting model for reservoirs. In this study, a reservoir was divided into main complex facilities to develop a model for the maintenance of the life cycle. A model was developed for each facility. For model development, maintenance information data were collected under management by the Rural Community Corporation. The data available for model development were selected by analyzing the collected data. The developed model was used to predict the expected life expectancy of the reservoir in the current maintenance system and the expected life expectancy in the case of no action. By using the developed model, it is expected that it will be possible to support decision making in operation management and maintenance while considering the life cycle of the reservoir.

DMSMS Management Survey and Analysis Method (부품단종에 대한 조사·분석 및 관리방안)

  • Jung, Hyun-Woo;Shim, Bo-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.257-265
    • /
    • 2020
  • Parts obsolescence is a component type, in which raw materials or parts that make up a weapons system, are developed and produced according to demand, but they age due to changes in technology or market conditions. The weapon system equipment currently being used by the military is having difficulty in procurement, maintenance, and operation because of the obsolescence of parts. Parts obsolescence during the life cycle of a weapons system affects not only the combat readiness of the military but also the economic loss of material, parts, and equipment manufacturers and suppliers. On the other hand, advanced technology has reduced the life span of electronic components that make up the weapons system. In addition, because of the nature of the weapons system, the obsolescence of components takes decades from development to disposal, which has a serious adverse effect on equipment readiness and life cycle costs. Therefore, it is necessary to manage systematically the parts obsolescence from development until the disposal of the weapons system equipment. This study examined the system of component control in developed countries to present a proper management plan for local situations and propose development plans for the early settlement of component control.

A Case Study on Green Pricing Program in USA (미국 Green Pricing 프로그램 평가 사례분석 및 시사점)

  • Lee, Ye-Ji
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.298-298
    • /
    • 2009
  • 미국의 DOE(Department of Energy)산하 EERE(Energy Efficiecy & Renewable Energy)에서 신재생 에너지 프로그램 평가를 하고 있다. 특히 General program evaluation Guide에는 많은 평가기관에서 제안되었던 5가지 방법 중 Outcome 평가는 프로그램의 목적을 얼마나 달성했는지를 측정하는 것으로 일정한 기간이 지난 후 프로그램의 목적을 달성함으로써 얻어지는 결과를 추산함으로써 그 기간 동안 프로그램이 의도했던 목적을 얼마나 잘 수행했는지를 보여준다. 한국에서 시행되고 있는 신재생에너지 보급 프로그램의 성과를 정량화 분석을 통하여 평가할 수 있어 국내 적용성이 크다. 본 연구에서는 미국 에너지부 EERE로부터 지원받아 NREL(National Renewable Energy Laboratory)에서 실행한 Utility Green Pricing 프로그램을 사례 분석하였다. Utility Green Pricing 프로그램은 1993년 시작되었으며 2002년 말 미국 전역의 300여개 시설을 통한 90개의 프로그램을 발전시킴으로써 소비자가 자발적으로 재생에너지 발전을 지원하기 위한 한 방법으로 최근 이런 프로그램 수는 증가하고 있다. 2002년 말 기준으로 국가 전기 사용자의 20%, 대략 270,000명의 소비자가 선택하였고 2002년 290MW급 재생에너지 설비용량과 2003년 140MW급 시설을 담당하였으며 미국 이외에 캐나다, 일본, 호주, 12개 유럽 국가들이 시행하고 있다. 이 프로그램 목표는 어떤 프로그램이 green pricing 프로그램의 소비자 참가와 재생에너지 구매의 최대화를 돕는지를 제공하는 것으로 Data Pool은 90개 프로그램 중 더 이상 실행하지 않는 4개를 제외한 86개로 응답률은 77%였다. 분석대상은 거주자와 비거주자로써 자료는 2003년 초 66개의 green pricing 프로그램의 질문서를 토대로 도출되었다. Green Pricing 프로그램 질문서는 참여, 지난해 판매, 재생에너지 공급, 할 증금(초과 구매력), 프로그램 디자인과 실행, 마케팅, 소비자를 위한 부가서비스 이렇게 총 7부분으로 나누어져있다. 특히 거주자와 비거주자와 참여, 재생에너지 판매량, 프로그램 수명, 사용하는 재생에너지의 종류, 프로그램 가격, 비용 할증료, 프로그램 평가의 종류, 프로그램 마케팅 노력, 참여자에게 제공되는 부수적 가치와 관련된 자료를 모으기 위해 실행되었다. 종속적 변수로 프로그램 유효성 측정과 관련된 비/거주자 참여와 재생에너지 구매를 선택하였으며 독립적 변수로 프로그램 디자인과 마케팅 특징을 들었다. 분석방법으로는 이변성과 다변성 통계적 분석을 이용하였다. 이변성 분석은 쉽게 개별적 독립 변수와 종속변수와의 직접적 관계를 보여주며 다변성 분석은 보다 정확한 영향 산정을 위해 선택한 복합적 독립변수를 이용하였다. 프로그램 유효성 측정을 위해 비/거주자 참여 퍼센트와 재생에너지 구매 퍼센트를 구하였다. 그러나 이 분석에 몇 가지 제한점이 있었다. 소비자 중 국외자의 영향으로 분석에 많은 영향을 주지 않지만 single utility 프로그램은 비거주자참여율과 재생에너지 구매율에 영향을 끼칠 가능성이 있으며 독립/설병변수를 프로그램성공을 위해 거듭 강조하지만 빠지거나 무딘 변수는 여전히 존재한다. 분석 대상이 2002년까지를 대상으로 하기 때문에 시간상의 지체 역시 문제가 될 수 있다. 다중공산성 역시 독립변수간의 상관관계가 나타나면서 발생된다. 하지만 몇 가지 재미있는 결과를 얻어냈다. 프로그램 기간이 소비자 응답에 영향을 미치며 초기 거주고객의 높은 구매력이 지속된다는 것이다. 가격 할증료와 최소 월사용료는 프로그램 성공 초기 결정요인이 되지 않는다. 작은 시설이 성공 달성가능성이 더 큰 것으로 나타났으며 비거주자의 사적 이득 제공 역시 성공 강화에 영향을 끼쳤다.

  • PDF