Background and Objectives: Obstructive sleep apnea (OSA) is often undiagnosed but is an important risk factor affecting the health of an individual. The level of awareness of the illness among patients with OSA is low and is not correlated with severity of the illness. This study was conducted to compare awareness of OSA symptoms and illness between patients with OSA and simple snorers. Materials and Methods: Two hundred eighty-two patients who were suspected of having OSA participated in this study. All subjects underwent overnight polysomnography. Those with an apnea-hypopnea index (AHI) ${\geq}5$ were classified as the OSA group, while those with an AHI < 5 were classified as the simple snoring group. A sleep questionnaire, which included items on awareness of the illness, OSA, and sleep symptoms, was administered to all subjects and their bed-partners. Results: Simple snorers were much more aware of their symptoms such as snoring, irregular breathing, and apnea than were patients with OSA. Bed-partners of simple snorers were also more aware of the participants' sleep symptoms than were partners of patients with OSA. However, the duration of OSA symptoms was longer in the OSA group. In the correlation analysis, the level of awareness of OSA symptoms was negatively correlated with AHI, age, body mass index, and Epworth Sleepiness Scale score. Among the sleep questionnaire and polysomnography results, only Pittsburgh Sleep Quality Index was positively correlated with level of awareness of OSA symptoms. The minority of the respondents had heard about the treatment methods of continuous positive airway pressure and oral appliance and preferred them as treatment options. Conclusion: This study suggests that simple snorers are more aware of their symptoms than are patients with OSA. A higher severity of OSA, represented by a higher AHI, is correlated with lower awareness of one's OSA symptoms.
Park, Kyung Won;Kim, Hyeong Wook;Choi, Mal Rye;Kim, Byung Jo;Kim, Tae Hyung;Song, Ok Sun;Eun, Hun Jeong
Sleep Medicine and Psychophysiology
/
v.24
no.2
/
pp.86-96
/
2017
Objectives: This study aimed to analyze causality among sleep apnea, depression and cognitive function in patients with obstructive sleep apnea. Methods: We reviewed the medical records of 105 patients with sleep apnea and snoring who underwent overnight polysomnography (PSG). We analyzed various biological data, sleep variables (sleep duration and percentage) and respiratory variables [arousal index (AI), periodic leg movement index (PLM index), snoring Index (SI), mean SpO2, minimum SpO2, apnea-hypopnea index (AHI), and respiratory disturbance index (RDI)]. We also analyzed various data by sleep, cognition, and mood related scales: Pittsburgh sleep quality index (PSQI), Epworth sleepiness scale (ESS), snoring index by scale (SIS), Montreal Cognitive Assessment-Korean (Moca-K), Mini-mental State Examination-Korean (MMSE-K), clinical dementia rating (CDR), and Beck Depression Inventory (BDI). We analyzed causation among sleep, and respiratory, mood, and cognition related scales in obstructive sleep apnea patients. We analyzed the mediating effects of depression on sleep apnea patient cognition. Results: As Duration N1 increased and Total sleep time (TST) decreased, MOCA-K showed negative causality (p < 0.01). As BDI and supine RDI increased, causality was negatively related to MOCA-K (p < 0.01). As PSQI (p < 0.001) and SIS (p < 0.01) increased and as MMSE-K (p < 0.01) decreased, causality was positively related to BDI. BDI was found to mediate the effect of age on MOCA-K in patients with obstructive sleep apnea. Conclusion: Duration N1, total sleep time, BDI, and supine RDI were associated with cognitive function in obstructive sleep apnea patients. Depression measured by BDI partially mediated cognitive decline in obstructive sleep apnea patients.
Objectives: Continuous positive airway pressure (CPAP) is effective in the treatment of obstructive sleep apnea syndrome (OSAS), but the major limitation of CPAP may be poor compliance. The aims of the study were to investigate the compliance and side effects of CPAP, and to evaluate the efficacy of CPAP in patients with OSAS. Methods: This study enrolled 106 patients with OSAS who took the CPAP treatment. The severity of daytime sleepiness was measured using Epworth Sleepiness Scale (ESS), and sleep quality and depressive symptoms were assessed by Pittsburgh Sleep Quality Index (PSQI) and Beck Depression Inventory (BDI), respectively. Results: During 29 months of the study period, 41.5% of patients were using CPAP and 38.7% of patients stopped using it. Compared to non-compliant patients, compliant patients had a higher PSQI score and obstructive apnea index. Among non-compliant patients, 51.2% of them stopped using CPAP within 1months. 85.7% of non-compliant patients were discomforted by the CPAP, but much more nasopharyngeal symptoms were reported in the compliant group. ESS (p<0.01), PSQI (p<0.01) and BMI (p<0.01) were reduced significantly after CPAP treatment but not BDI (p=0.86). Conclusions: We concluded that CPAP can reduce the daytime sleepiness, nocturnal sleep disturbance, and body mass index. To increase the compliance of CPAP, we suggest that some education and support are needed at the early stage of the CPAP treatment.
Journal of the Korea Society of Computer and Information
/
v.25
no.7
/
pp.113-123
/
2020
Obstructive sleep apnea (OSA) among sleep disorders is one of relatively common diseases. Patients can be checked for the disease through sleep polysomnography. However, as far as he diagnosis of OSA using polysomnography (PSG) is concerned, many practical problems such as an increasing number of patients, expensive testing cost, discomfort during examination, and the limited number of people for testing have been pointed out. Accordingly, for the purpose of substituting PSG researchers have been actively conducting studies on OSA diagnosis based on machine learning using bio signals. In this regard, we review a rich body of existing OSA diagnosis studies applying machine learning techniques based on bio-signal data. As a result, this paper presents a novel taxonomy of the reviewed studies and provides their comprehensive comparative analysis results. Also, we reveal various limitations of the studies using the bio signals and suggest several improvements about utilization of the used machine learning methods. Finally, this paper presents future research topics related to the application of machine learning techniques using bio signals.
Journal of the korean academy of Pediatric Dentistry
/
v.47
no.4
/
pp.377-388
/
2020
The aim of this study was to evaluate the association between various predicting tools and Apnea-Hypopnea Index (AHI) to identify children with sleep disordered breathing (SDB). From 5 to 10 years old who came for orthodontic counseling, 61 children, whom had lateral cephalograms, pediatric sleep questionnaire (PSQ) records, and portable sleep monitoring results, were included in this study. A total of 17 measurements (11 distances and 6 angles) were made on lateral cephalograms. The measurements of lateral cephalograms, PSQ scales and portable sleep monitoring results were statistically analyzed. 49 of 61 (80%) patients showed AHI > 1, which suspected to have SDB and their mean AHI was 2.75. In this study, adenoid size (A/N ratio), position of the hyoid bone from mandibular plane, gonial angle, and PSQ scale were related to a higher risk of pediatric SDB. Also, oxygen desaturation index (ODI) and snoring time from sleep monitoring results were statistically significant in children with SDB using Mann-Whitney test (p < 0.05). In conclusion, evaluation of hyoid bone position, adenoidal hypertrophy, gonial angle in lateral cephalogram, and PSQ scale was important to screen out potential SDB, especially in children with frequent snoring.
Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.
Objectives : High co-morbidity of periodic limb movements during sleep(PLMS) and obstructive sleep apnea syndrome(OSAS) is well known and their incidences tend to increase in the elderly. Previous studies have inconsistently rep0l1ed increase or no change of periodic limb movement index(PLMI) by nasal continuous positive airway pressure(CPAP) in OSAS without analyzing possible variables affecting PLMI. We attempted to examine PLMI change evoked during CPAP titration and also factors affecting it in OSAS. Methods : Twenty-nine OSAS patients(M:F=26:3, mean age: $51.6{\pm}10.6\;yrs$) without other sleep disorders except for PLMS were selected, based on the nocturnal (baseline) polysomnograhy. Another night of noctumal polysomnography was performed for CPAP pressure titration. We compared between those two nights PLMI, mean and lowest $SaO_2$, and sleep variables. We also calculated PLMI differences between baseline and CPAP nights, named as delta PLMI (value of CPAP night PLMI minus value of baseline night PLMI). Correlations were calculated between delta PLMI and factors such as age, body mass index, applied CPAP pressure, baseline night values of respiratory disturbance index, mean and lowest $SaO_2$, and sleep parameter differences between baseline and CPAP nights. Results : Decrease of RDI(p<.01) and increase in mean and lowest $SaO_2$ (p<.05, p<.01) were observed during CPAP night. No sleep parameters showed significant change except for the decrease of total stage 1 sleep%(p<.01) during CPAP night. Ten out of 29 patients showed PLMI increase, while the other 19 patients showed either no change(n=14) or even PLMI decrease(n=5) during CPAP night. The 10 patients showing PLMI increase during CPAP night showed a significant positive correlation between delta PLMI and baseline night RDI(p<.05), which meant that PLMI increase was found to be more prominent in higher RDI patients than in lower RDI ones. There were no significant correlations between delta PLMI and other factors in the other 19 patients. Conclusions : We suggest that during the baseline night PLMS would have been underscored and/or masked due to the overlapping of PLMS and apneas/hypopneas or the arousals induced by apneas/hypopneas. Despite its still unknown mechanism, the CPAP application may unmask PLMS and increase PLMI in a subgroup of OSAS patients. It needs to be evaluated further whether the chronic CPAP use sustains the above finding.
Journal of the Institute of Electronics Engineers of Korea SC
/
v.42
no.3
s.303
/
pp.47-52
/
2005
Obstructive Sleep Apnea (OSA) is a representative symptom of sleep disorder caused by the obstruction of upper airway. Because OSA causes not only excessive daytime sleepiness and fatigue, hypertension and arrhythmia but also cardiac arrest and sudden death during sleep in the severe case, it is very important to detect the occurrence and the frequency of OSA. OSA is usually diagnosed through the laboratory-based Polysomnography (PSG) which is uncomfortable and expensive. Therefore researches to improve the disadvantages of PSG are needed and studies for the detection of OSA using only one or two parameters are being made as alternatives to PSG. In this paper, we developed an algorithm for the detection of OSA based on Heart Rate Variability (HRV). The proposed method is applied to the ECG data sets provided from PhysioNet which consist of learning set and training set. We extracted features for the detection of OSA such as average and standard deviation of 1 minute R-R interval, power spectrum of R-R interval and S-peak amplitude from data sets. These features are applied to the input of neural network. As a result, we obtained sensitivity of $89.66\%$ and specificity of $95.25\%$. It shows that the features suggested in this study are useful to detect OSA.
Kim, Kyoung-Woo;Yoon, Seok-Joon;Yang, Chang-Kook;Han, Hong-Moo
Korean Journal of Psychosomatic Medicine
/
v.10
no.1
/
pp.37-47
/
2002
Objective : Previous studies have suggested an association between sleep-related breathing disorder (SRBD) and several psychological problems, and there were increasing recognition of the link. The purpose of this study is to evaluate the characteristic profiles of MMPI and SCL-90-R in patients with SRBD. Methods : This study consisted of 80 SRBD patients(73 men, 7 women) referred from Sleep Disorder Clinic of Dong-A University Hospital, Busan, Korea. Basic informations including demographic findings and physical examination were collected. Subjects completed the Epworth Sleepiness Scale(ESS), Minnesota Multiphasic Personality Inventory(MMPI), and Symptom Check List-90-Revision (SCL-90-R) prior to standard overnight polysomnography that was performed at hospital sleep laboratory. SRBD was divided into two groups of primary snoring(PS) and obstructive sleep apnea(OSA) according to polysomnographic findings. Results : SRBD showed significant elevation rate of Hs, D, and Hy scales of MMPI and SOM scale of SCL-90-R, which exceeded the rate expected in normal individuals(>5%, 2SD). On comparison of clinical scales of SCL-90-R, OSA group had significantly greater mean score than that of PS group in terms of O-C, DEP, PAR, GSI(p<0.05), SOM and PST(p<0.01). OSA group also showed significantly higher elevation rate in Hs scale of MMPI and SOM scale of SCL-90-R than that of PS. Among OSA group, three scales of MMPI(D, Pt, Si) and three scales of SCL-90-R(ANX, PAR, PSDI) had significant correlation with some PSG variables including total sleep time and sleep efficiency. Among PS group, two scales of MMPI(Hy and Pt), elevation rate of MMPI scales and three scales of SCL-90-R(I-S, PAR, PSDI) had significant correlation with some PSG variables including sleep efficiency, sleep latency and REM sleep percent. Conclusion : The above results suggest that SRBD show neurotic profiles in MMPI and SCL-90-R. This study also clearly indicates that PS group are suffered from clinically meaningful psychiatric symptoms, which are quantitatively lessened but qualitatively similar as compared to that of OSA group.
Periodic limb movements during sleep (PLMS) are prevalent in various sleep disorders, such as restless legs syndrome (RLS), periodic limb movements disorder, obstructive sleep apnea (OSA), REM sleep behavior disorder (RBD), and narcolepsy. PLMS has been hypothesized to be related to the decline of dopaminergic transmission. In RLS, PLMS is suggested to be related to iron deficiency and symptom severity. PLMD is a rare sleep disorder, and the role of PLMS in PLMD has not been clearly investigated yet. PLMS in OSA, which remain after proper PAP therapy, may need further management. The clinical relevance of PLMS in RBD and narcolepsy have not been investigated thoroughly and need further studies. Whether PLMS are to be considered as a mere symptom of individual sleep disorders or not can be elucidated through studies investigating the efficacy of therapeutic approaches to reduce PLMS in various sleep disorders.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.