• Title/Summary/Keyword: 수류순환

Search Result 11, Processing Time 0.023 seconds

Field Applications of Non-powered Downward Water Circulation System to Improve Reservoir Water Quality (저수지 수질개선을 위한 무동력 하향류 수류순환시스템의 현장적용성)

  • Jang, YeoJu;Lim, HyunMan;Jung, JinHong;Park, JaeRho;Kim, WeonJae
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.2
    • /
    • pp.109-119
    • /
    • 2019
  • Eutrophication has occurred due to the inflow of various water pollutants in many Korean reservoirs with low depth, and algal blooms of surface layer and low oxygenation of deep layer have repeated every year. There are several existing technologies to alleviate the stratification of reservoirs, but it is difficult to apply them in field sites due to the necessity of electric power and low economic efficiency. In this study, a non-powered water circulation system using natural energy of wind and water flow has been developed, and two test-beds constructed in the reservoirs with different conditions and examined its field applicability. Through computational fluid dynamics (CFD) simulation, it has been shown that the water circulation system could induce the downward flow to mitigate the stratification between surface and deep layers, and its influence radius could reach about 30 m. As a result of long-term monitoring of the test-beds, various water quality improvement effects have been observed such as moderation of DO fluctuation by water circulation, reduction of DO supersaturation and prevention of excessive pH rising. In order to improve the applicability of the water circulation system, it is considered necessary to review countermeasures against flood and depth conditions of each reservoir.

성유굴의 지형 분석

  • 홍시환
    • Journal of the Speleological Society of Korea
    • /
    • v.8 no.9
    • /
    • pp.6-14
    • /
    • 1983
  • 성유굴도 다른 석회동굴과 같이 지면에 투수된 지하수에 의하여 그 지반을 덮고 있는 석회암층이 용해, 용식되면서 지면하에 용출이 생겼다. 물론 지하수대가 순환수대인 경우도 있고 한편 포화수대상태에 있는 경우의 두 가지가 있는데 성유굴은 포화수대의 지하수면하에서 형성된 것이다. 그리고 그후에 순환수류의 영향을 받게 되었다. (중략)

  • PDF

울진성유굴의 퇴적물조사

  • 홍시환
    • Journal of the Speleological Society of Korea
    • /
    • v.9 no.10
    • /
    • pp.57-65
    • /
    • 1984
  • 성유굴도 다른 석회동굴과 같이 지면에 투수된 지하수에 의하여 그 지반을 덮고 있는 석회암층이 용해, 용식되면서 지면하에 동굴이 생겼다. 물론 지하수대가 순환수대인 경우도 있고 한편 포화수대상태에 있는 경우의 두가지가 있는데 성유굴은 포화수대의 지하수면하에서 형성된 것이다. 그리고 그후에 순환수류의 영향을 받게 되었다. (중략)

  • PDF

Design and Cold Flow test of a Multi-injector Engine using Hydrogen Peroxide/Kerosene (과산화수소 케로신을 추진제로하는 다중 인젝터 설계 및 수류실험)

  • Kim, Ki-Woo;Jeon, Jun-Su;Park, Jin-Ho;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.95-98
    • /
    • 2010
  • A multi-injector rocket engine using high concentrated hydrogen peroxide and kerosene as the oxidizer and fuel was designed and fabricated. Six coaxial swirl injectors were mounted on the mixing head and flow analysis in the manifold was performed to minimize stagnation and recirculation zones. Finally, uniformity of mass flow rate and spray pattern was evaluated by cold flow tests and the mixing head design process was successfully verified the results.

  • PDF

A Study on the Circulating Water Purification System using Oxygen Solubilization and Diffusion Device (산소용해수와 확산장치를 결합한 순환형 수질정화 장치의 검증)

  • Ahn, Chang-Hyuk;Song, Ho-Myeon;Joo, Jin-Chul;Lee, Yeon-Ku;Kim, Il-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.318-318
    • /
    • 2011
  • 자연수를 가압(4~5기압)하면서 물과 공기의 비를 4:1~3:1로 혼합하면 수체 내 초미세기포(Diameter $3{\sim}10{\mu}m$)가 발생하는데 이를 산소용해수라 하며 수질정화시설 또는 양식장 등에 널리 사용되고 있다. 산소용해수의 특징은 기포의 비표면적이 넓고 10시간 이상 포화 농도를 유지하여 수체에 잔류하는 시간이 길기 때문에, 일반 산기석을 활용한 포기나 순산소 용해 등의 타 방법과 구별된다. 산소용해수의 산소전달효율은 기존 방법과 큰 차이를 보이기 때문에 실제 적용시에는 대상수를 이용하여 산소전달계수($K_{L}a$)를 사전에 산정할 필요가 있다. 본 연구에서는 한국건설기술 연구원의 안동 수자원 환경실험센터 내 실외형 콘크리트 사각반응수조에 산소용해장치 및 확산장치를 결합한 일체형 시스템을 적용시켜 2010년 9월~2011년 1월의 5개월간 결과를 분석, 본 장치의 $K_{L}a$를 산정 후 수질정화의 활용 면에서 검토하였다. $K_{L}a$의 산정에는 다양한 방법이 이용되나 용존 산소 농도의 제어에 한계가 있는 실외 대형실험장에 적합한 Lewis and Whitman의 Two-film 이론에 근거한 정상포기법을 적용하였다. 체적 $80m^3$의 수조 내에서 현장 유지용수를 대상으로 실험한 결과 산소전달계수는 $0.324\pm0.050$/min, 포화농도는 8.64 mg $O_2$/L, 도달시간은 11 /min이 산정되었으며, 이는 기존 산기석 포기의 산소전달계수 범위인 $0.105\pm0.019$ /min보다 약 3.1배 높은 결과를 보였다. 또한, 확산장치의 수류 순환 방향 및 정도를 검토하기 위하여 실험수조에서 1m단위로 격자를 구성한 후 초음파 유속계로 실측한 결과 0.0~2.5 m/s 의 평면적 유속범위를 도출하였다. 그리고 전체 순환을 고려했을 때 용존산소는 약 8시간 후 8.64 mg $O_2$/L 값에 도달하여 안정화 되었으며, 강한 수류순환과 산소용해수에 의해 하상에 존재하는 퇴적물들의 이송 및 산화촉진을 유도하였다. 이를 근거로 실험수조의 체적과 기준 가동시간인 8시간을 적용시켰을 때, 실험구 수질은 대조구와 비교하여 COD, T-N, T-P가 모두 25~35% 개선되었다. 이 결과는 여과공정 없이 단순 순환만을 고려한 물리적 수질정화 방법의 단독 활용 가능성을 나타내며, 기존 연구에서 나타난 SOD (Sediment oxygen demand) 저감 능력을 감안할 때 향후 폐쇄성 수역의 수질관리에도 효율적으로 활용할 수 있음을 시사한다.

  • PDF

Design and Cold Flow Test of a Multi-injector Engine using Hydrogen Peroxide/Kerosene (과산화수소/케로신을 이용한 다중 분사기 엔진 설계 및 수류 실험)

  • Lee, Yang-Suk;Jeon, Jun-Su;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.1
    • /
    • pp.36-44
    • /
    • 2012
  • Multi-injector rocket engine using high-concentrated hydrogen peroxide and kerosene was designed and manufactured. Design requirements of a rocket engine were determined and main geometrical parameters of rocket engine were determined on the basis of fundament. Six coaxial swirl injectors were mounted on the multi-injector engine. Flow analysis in the hydrogen peroxide manifold was performed to minimize stagnation and recirculation zones. Finally, the optimized hydrogen peroxide manifold was manufactured and cold flow test was carried out to confirm mass flow rate per uni-element, spray pattern and atomization characteristics. The results of cold flow test showed that the mixing head design process was successful and enough to use as a essential database for the development of a full-scale engine.

Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant (정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석)

  • Song K. S.;Oh S. Y.;Park Y. B.
    • Journal of computational fluids engineering
    • /
    • v.7 no.2
    • /
    • pp.1-7
    • /
    • 2002
  • The present study is developed device that effectively mixes raw water and chemicals by using the residual head of fluid in the front pipe of flocculation basin, and performed non-dimensional analysis and presented design standard to apply to water plants that have different equipment capacity. The variables for design are a proper ratio between an outer diameter of deflector and a diameter of pipe, a distance between deflector and orifice and a determination of orifice diameter for an optimal mixing. Numerical study has analyzed flow field on a basis of turbulent intensity in an orifice downstream. As Reynolds number of In-Line Orifice was increased from identical design variable, the turbulent intensity of pipe center was no changed almost.

Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant (정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석)

  • Song K. S.;Oh S. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.132-137
    • /
    • 2001
  • We used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Code of computational fluid dynamics for numerical analysis was performed using FLUENT, a commercial code. As variable for exactly standardizing, a proper ratio between an outer diameter of deflector and a diameter of pipe, the distance between deflector and orifice, a determination of orifice diameter fur an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Vertebral abnormality in Hatchery-reared River puffer, Takifugu obscurus fingerlings (인공종묘 생산 황복 (Takifugu obscurus) 치어의 척추 변형에 관하여)

  • Park, Sung-Woo;Kang, Kook-Hee
    • Journal of fish pathology
    • /
    • v.20 no.2
    • /
    • pp.129-137
    • /
    • 2007
  • Skeletal deformity in hatchery-reared river puffer (Takifugu obscurus) fingerlings occurred. The vertebral abnormality was recognized with naked eyes 80 days after hatching. Affected fish had a good appetite but no clinical signs were found except the vertebral abnormality. As more than 90% of the hatchery-reared fish exhibited vertebral abnormality, the fingerlings could not be used for commercial seeds any more. Morphological changes in the vertebrate and the swim bladder were observed with a soft X-ray. Histopathological changes on the caudal muscle around the deformed vertebrae, gill, and spleen were also examined to clarify the cause of the deformity. Spinal curvature occurred between vertebrae 10 and 12, but any malfunction of the swim bladder was not found. The diameters of the muscle fibers around the deformed vertebrae were much smaller and more irregular than those in normal fish, and the gabs between the fiber bundles were greatly enlarged. No evidence of inflammation response was found in the muscle layer. In the hatchery, feed was putting at the position of water inflow, which might attract the fingerings to move toward the feed in spite of incomplete development of their caudal muscle fibers. From these results, it is suggested that the high speed of water current in rearing aquaria might be associated with the development of vertebral abnormality.

Development and Application of Multi-Functional Floating Wetland Island for Improving Water Quality (수질정화를 위한 다기능 인공식물섬의 개발과 적용)

  • Yoon, Younghan;Lim, Hyun Man;Kim, Weon Jae;Jung, Jin Hong;Park, Jae-Roh
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.221-230
    • /
    • 2016
  • Multi-functional floating wetland island (mFWI) was developed in order to prevent algal bloom and to improve water quality through several unit purification processes. A test bed was applied in the stagnant watershed in an urban area, from the summer to the winter season. For the advanced treatment, an artificial phosphorus adsorption/filtration medium was applied with micro-bubble generation, as well as water plants for nutrient removal. It appeared that the efficiency of chemical oxygen demand (COD) and total phosphorus (T-P) removal was higher in the warmer season (40.9%, 45.7%) than in the winter (15.9%, 20.0%), and the removal performance (suspended solid, chlorophyll a) in each process differs according to seasonal variation; micro-bubble performed better (33.1%, 39.2%) in the summer, and the P adsorption/filtration and water plants performed better (76.5%, 59.5%) in the winter season. From the results, it was understood that the mFWI performance was dependent upon the pollutant loads in different seasons and unit processes, and thus it requires continuous monitoring under various conditions to evaluate the functions. In addition, micro-bubbles helped prevent the formation of anaerobic zones in the lower part of the floating wetland. This resulted in the water circulation to form a new healthy aquatic ecosystem in the surrounding environment, which confirmed the positive influence of mFWI.