• Title/Summary/Keyword: 수력원자력

Search Result 418, Processing Time 0.02 seconds

Review on Regulatory and Technical Standards of Radiation Protection for Lens of the Eye (수정체 방사선 방호에 관한 규제기준 및 기술기준 검토)

  • Si Young Kim;Seok-Ju Hwang;Jae Seong Kim;Jung-Kwon Son
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • The International Commission on Radiological Protection (ICRP) lowered the annual equivalent dose limit of lens of the eye for radiation workers from 150 to 20 mSv in April 2011. This trend of lowering the equivalent dose limit for radiation workers has been observed worldwide, including international organizations such as the International Atomic Energy Agency (IAEA), International Organization for Standardization (ISO) and the European Commission (EC). In 2016, the Nuclear Safety and Security Commission of South Korea published research results that included a proposal for lowering the equivalent dose limit of lens of the eye for radiation workers in line with the ICRP recommendation. However, as of now, South Korea's Nuclear Safety Act and related regulations still specify an annual equivalent dose limit of lens of the eye as 150 mSv for radiation workers. The IAEA and ISO have issued guidelines regarding radiation protection for lens of the eye and recommended a dose level for the lens of the eye at 5 or 6 mSv per year for periodic monitoring of the equivalent dose for the lens of the eye.

벨기에의 원자력발전 개발현황

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.8 no.3 s.61
    • /
    • pp.14-16
    • /
    • 1988
  • 국내 부존에너지자원이 석탄과 소규모의 수력발전 뿐인 벨기에의 에너지정책은 원자력발전계획을 성공적으로 추진하는 것이다. 다음은 영국 원자력공사 (UKAEA)가 발행하는 ${\ulcorner}$ATOM${\lrcorner}$지 '88년 1월호에 소개된 벨기에의 원자력발전개발현황이다.

  • PDF

The Regulatory Effects of Low-Dose Ionizing Radiation on Ikaros-Autotaxin Interaction (저선량 방사선에 의한 Ikaros-Autotaxin 상호작용 조절 효과)

  • Kang, Hana;Cho, Seong-Jun;Kim, Sung Jin;Nam, Seon Young;Yang, Kwang Hee
    • Journal of Radiation Industry
    • /
    • v.10 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • Ikaros, a transcription factor containing zinc-finger motif, has known as a critical regulator of hematopoiesis in immune system. Ikaros protein modulates the transcription of target genes via binding to the regulatory elements of the genes promoters. However the regulatory function of Ikaros in other organelle except nuclear remains to be determined. This study explored radiation-induced modulatory function of Ikaros in cytoplasm. The results showed that Ikaros protein lost its DNA binding ability after LDIR (low-dose ionizing radiation) exposure. Cell fractionation and Western blot analysis showed that Ikaros protein was translocated into cytoplasm from nuclear by LDIR. This was confirmed by immunofluorescence assay. We identified Autotaxin as a novel protein which potentially interacts with Ikaros through in vitro protein-binding screening. Co-immunoprecipitation assay revealed that Ikaros and Autotaxin are able to bind each other. Autotaxin is a crucial enzyme generating lysophosphatidic acid (LPA), a phospholipid mediator, which has potential regulatory effects on immune cell growth and motility. Our results indicate that LDIR potentially regulates immune system via protein-protein interaction of Ikaros and Autotaxin.

미리가본 서기 2000년

  • 한국발명진흥회
    • 발명특허
    • /
    • v.10 no.10 s.116
    • /
    • pp.52-53
    • /
    • 1985
  • 서기 2000년이 되어도 현재 에너지 공급의 대부분을 차지하고 있는 석탄, 석유, 가스등 화석연료는 동력원의 대부분을 차지할 것이다. 그러나 원자력이 새로운 에너지로서 원자력선, 원자력 열차, 원자력 비행기가 등장할 것이고 이어 원자력 우주선도 선보일 것이 확실하다. 또 지열은 난방에, 수력과 풍력 그리고 조수등은 모두 발전에 이용될 것이다.

  • PDF

안전감압계통의 열수력과도현상 평가

  • 이희도;윤선홍;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.186-192
    • /
    • 1996
  • 가압기의 유체 조건이 증기에서 이상유체로 변화하는 완전급수상실사고 경우에 대한 안전감압계통의 가압기 노즐 및 밸브 전단에서의 유량, 밸브 후단에서의 압력 변화 등 RELAP5/MOD1과 RELAP5/MOD3로 계산된 열수력 조건이 유사한 추세를 나타내었다. 또한 RELAP5/MOD1-CALPLOTFIII와 RELAP5/MOD3-CALPLOTFIII 전산체제로 계산된 안전감압계통의 각 배관부위에서의 동하중도 유사한 추세를 나타내었다. 즉, RELAP5/MOD1-CALPLOTFIII와 RELAP5/MOD3-CALPLOTFIII 전산체제를 이용한 안전감압계통의 열수력 과도현상 해석 결과가 유사하여 RELAP5/MOD1 대신에 RELAP5/MOD3가 안전감압계통의 열수력 과도현상 분석에 대체사용될 수 있을 것으로 판단된다. 그러나 본 연구는 안전감압계통에 국한하여 수행되었으며, RELAP5/MOD1과 RELAP5/MOD3를 이용한 가압기안전밸브 방출배관에 대한 기존의 연구 결과에 의하면 RELAP5/MOD3가 만족스러운 곁과를 제공하지 못하는 바, 다른 계통에 RELAP5/MOD1 대신 RELAP5/MOD3를 대체적용하기 위해서는 개별적으로 각 계통에 대한 비교 평가가 선행되어야 할 것으로 판단된다.

  • PDF