• Title/Summary/Keyword: 수두차

Search Result 59, Processing Time 0.02 seconds

Feasibility Study for Tidal Power Plant Site in Garolim Bay Using EFDC Model (EFDC모형을 이용한 가로림만의 조력발전 위치 타당성 검토)

  • Shin, Bum-Shick;Kim, Kyu-Han;Kim, Jong-Hyun;Baek, Seung-Hwa
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.6
    • /
    • pp.489-495
    • /
    • 2011
  • Fossil fuel energy has become a worldwide environmental issue due to its effect on global warming and depletion in its supply. Therefore, the interest in developing alternative energy source has been rising. Ocean energy, especially, has gained strength as an alternative energy source for its unlimited supply with low secondary risks. Among all the ocean energy, the west coast of Korea holds the field of large-scale energy development because of its distinctive tidal range. Tidal power plant construction at the sea may expedite multi development effects such as bridge roles, tourism resource effects and adjustability of flood inundation at the inner bay. This study introduces the validity of tidal power plant construction at Garilim Bay in west coast of Korea by examining anticipated hydraulic characteristics using EFDC model. Through EFDC numerical simulations, the feasibility of Garolim Bay as a tidal power plant field has been proved. And the most effective tidal power plant construction would be to install hydraulic turbine in the west side of bay entrance where ebb current is stronger, and install water gate in the east side of bay entrance where the flood current is superior.

An Experimental Study of Wave Overtopping Characteristics on the Structure for Wave Overtopping Power Generating System (월파형 파력발전구조물의 월파 특성에 관한 실험적 연구)

  • Shin, Seung-Ho;Hong, Key-Yong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.8 s.114
    • /
    • pp.649-655
    • /
    • 2006
  • Waves progressing into the coastal area can be amplified, swashed and overtopped by a wave overtopping control structure, and it converts the kinetic energy of the waves to the potential energy with a hydraulic head above the mean sea level by conserving the overflow in a reservoir. Then the potential energy in the form of hydraulic head can be converted to electric power utilizing extremely low-head hydraulic turbine. This study aims to find the most optimal shape of wave overtopping structure which maximizes overtopping volume rate of sea water. Laboratory experiments for the performance evaluation of wave overtopping control structures were carried out in three dimensional wave tank, and the three dimensional structure models with planar wave concentration shapes(B/b) were manufactured into five classes, which were optimized by cross sectional parameters of the structure, ie, length of ramp(l), gradient of inclined ramp($cot{\phi}$) and freeboard height of the wave overtopping structure($h_e$) proposed by Shin and Hong(2005). The wave overtopping discharges were investigated with 20 incident wave conditions and wave directions of $0^{\circ},\;15^{\circ},\;30^{\circ}$.

Analysis of the Effects of Drainage Systems in Wetlands Based on Changes in Groundwater Level, Soil Moisture Content, and Water Quality (지하수위, 토양수분함량 및 수질변화를 활용한 습윤화 지역의 배수시설 효과 평가)

  • Kim, Chang-Hoon;Ryu, Jeong-Ah;Kim, Deog-Geun;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.26 no.2
    • /
    • pp.251-260
    • /
    • 2016
  • Groundwater flow due to hydraulic gradients across a geologic barrier surrounding a dam reservoir can cause swamps or wetlands to form on the downstream side of the dam, thereby restricting land use. The difference in head between the reservoir level and the downstream groundwater level creates a hydraulic gradient, allowing water to flow through the geologic barrier. We constructed a drainage system at the Daecheong dam to study the effects on groundwater levels and soil moisture contents. The drainage system consisted of a buried screened pipe spanning a depth of 1-1.5 m below a land surface. Groundwater levels were monitored at several monitoring wells before and after the drainage system was installed. Most well sites recorded a decline in groundwater level on the order of 1 m. The high-elevated site (monitoring well W1) close to the reservoir showed a significant decline in groundwater level of more than 2 m, likely due to rapid discharge by the drainage system. Soil moisture contents were also analyzed and found to have decreased after the installation of the drainage system, even considering standard deviations in the soil moisture contents. We conclude that the drainage system effectively lowered groundwater levels on the downstream side of the dam. Furthermore, we emphasize that water seepage analyses are critical to embankment dam design and construction, especially in areas where downstream land use is of interest.

Appropriate Technology and Field Application of Non-powered Water Purification System Using Nanofiber Membrane (나노섬유 멤브레인 기반 무동력 정수 시스템의 적정기술 및 현장 적용)

  • Lee, Jin;Yun, Byeong Gweon;Han, Kyoung Gu;Lee, Seung Hoon;Kim, Cheol Hyeon;Kim, Chan;Lee, Yunho;Lee, Dongwhi;Lee, Seunghyeok;Kim, Kyoung-Woong
    • Journal of Appropriate Technology
    • /
    • v.7 no.1
    • /
    • pp.72-81
    • /
    • 2021
  • Gravity-driven membrane (GDM) filtration system based on the nanofiber membrane was investigated. This system can be operated with little energy demand due to a gravitational pressure-driven filtration and biological fouling control strategy. Moreover, the optimal module configuration based on the high permeance of nanofiber membrane can provide a significantly high water productivity. In order to evaluate its applicability potential, the pilot-scale (3000-5000 L/day) systems with nanofiber membranes were operated in developing countries (Kiribati and Tuvalu). Our results showed that the 14-92 L/(m2×h) of the permeate flux was determined indicating a stabilized water productivity. In addition, the permeate water indicated a high removal rate (more than 99.99%) of turbidity and bacteria. Consequently, the system can provide a stabilized water production with safe permeate water quality during long-term operation. These findings exemplify an effective approach to decentralized drinking water treatment for developing countries.

Simultaneous Removal of Cd and Cr(VI) in the Subsurface Using Permeable Reactive Barrier Filled with Fe-loaded Zeolite: Soil Box Experiment (Fe-loaded zeolite로 충진된 투수성 반응벽체를 이용한 지반 내 Cd과 Cr(VI)의 동시제거: 모형 토조 실험)

  • Rhee, Sung-Su;Lee, Seung-Hak;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.10
    • /
    • pp.61-68
    • /
    • 2010
  • A pilot-scale model test was performed to estimate the availability of new material, Fe-loaded zeolite, as the filling material in permeable reactive barrier (PRB) against the contaminated groundwater with both Cd and Cr(VI). Aquifer was simulated by filling up a large scale soil tank with sands, and mobilizing the water flow by the head difference of water level in both ends of the tank. Then, the mixture of concentrated Cd and Cr(VI) solution was injected into the aquifer to form a contaminant plume, and its behavior through Fe-loaded zeolite barrier was monitored. The test results showed that Fe-loaded zeolite barrier successfully treated the contaminant plume containing both Cd and Cr(VI) and that the immobilized contaminants in the barrier were not desorbed or released. The results indicated that the Fe-loaded zeolite could be a promising material in PRBs against the multiple contaminants with different ionic forms like Cr(VI) and Cd.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Performance Characteristics with Various Fuel Composition and Temperature for an External Type Fuel Pump in LPLi System (LPLi 시스템에서 외장형 펌프의 연료조성 및 온도에 따른 성능특성 연구)

  • Nam, Deok-Woo;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.566-575
    • /
    • 2011
  • Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.

Discharge Variation of Perforated Hoses and Drip Irrigation Systems for Protected Cultivation (시설재배용 분수호스 및 점적관수 시스템의 관수균일도 분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.297-302
    • /
    • 2007
  • Discharge variations of perforated hose and drip irrigation systems were examined to evaluate irrigation uniformity at different pressures and length of branch line. Evaluation using statistical uniformity indicated that button drippers performed at excellent level but drip tapes and drip hoses were a little lower level. Nominal discharge of drip irrigation systems showed at the high side within the range of regulating pressure provided by the manufacturer. It is desirable that the length of branch line for drip hose, drip tape, and button dripper should be limited to 50 m, 70 m, and 100 m, respectively. Irrigation uniformity of perforated hoses showed very low level. So it is recommended that the length of branch line for perforated hoses should be limited to $30{\sim}35m$.

Flow Characteristics for the Variation of Total Angles in Open Channel Bends (개수로 만곡부에서의 중심각 변화에 따른 흐름특성)

  • Lee, Jong Tae;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.195-202
    • /
    • 1987
  • The flow characteristics in the shallow open channel bends are investigated, whose total angles were 30, 60, 90, 120, 150 and 180 in degree, and whose bed frictions were relatively rough(C=30) and smooth(C=60), respectively. The terms analyzed in this study are the water surface profile, the distribution of velocity and the flow direction, relating to the various total angles in the bends. The maximum depth in the bends could be found at the outside section of the location of $15^{\circ}$ local angle from the bend inlet, having no relation to the total angle and bed friction. It is supposed that the path of maximum velocities is especially influenced by the bottom friction when the total angles are bigger than 150 in degree, approximately. The ratio of the superelevation to the velocity head seems to increase as the total angle of the bends increases. The flow direction is skewed to the inner side at the bend inlet, and skewed to the outside at the bend outlet, regardless of their total angles.

  • PDF

Performance Evaluation for Water Quality Enhancement (수질향상을 위한 정수장 성능평가)

  • Simpson Stephen-L;Singer Charlie
    • 수도
    • /
    • v.24 no.4 s.85
    • /
    • pp.30-38
    • /
    • 1997
  • County는 비용과 부지소요는 최소화하면서도 증가하는 지역적 물수요에 부합되는 높은 유량에서 정수장의 성능을 최대화해야하는 필요성에 직면해있다. 개선사항을 찾아내기 위하여 시설물에 대한 상세한 성능평가가 행해졌다. 성능평가는 여과와 소독공정이 운전방식의 조정과 함께 추가시설의 건설에 의하여 개선될 수 있음을 나타내었다. Pilot test는 실험된 여러 가지 대안들 중에서 혼화, 응집, 이중 여과방식이 입자의 제거와 정수 수질에 가장 좋은 것임을 보여주었다. 소독에 대한 분석 결과는 소독방법을 교정하고 추가적인 염소접촉시간을 주는 것이 소독의 안전성을 확보함과 동시에 정수의 소독부산물 농도를 최소한으로 하고 강화되는 규제치와 부합할 수 있는 최선의 방법이 될 것이라는 것을 보이고 있다. Pilot test는 저수두 자동역세척여과지가 1차여과지(roughing filter)로서 효과적이라는 것을 보여주었다. 실험결과는 이중여과가 최종유출수의 탁도를 평균 0.1NTU이하로 감소시키며 입자의 제거율을 3 log로 증가시킴을 나타내고 있다. 정수공정 전반에서의 입자의 제거는 여러 개의 공정의 개별적 성과의 합이 아니므로 시설물들을 건설하기 전에 정수장 전체적으로 예상되는 개선정도를 수량화하기 위하여 Pilot 실험이 필요하였다. Pilot test중에 탁도보다는 입자측정이 유량, 응집제의 주입량, 및 여타 운전조건의 변화에 훨씬 민감함을 보여주었다. 이러한 점이 입자측정이 특히 저탁도 원수에서 처리공정의 성능을 나타내 주는 적절한 추가적 수질인자라는 결론을 보강하여 주었다. 물수요에 부합하기 위하여 Freedom District 정수장을 성공적으로 개선하는 데는 원수의 수질, 단위공정의 성능, 활용가능한 수리학적 수두, 현시설의 배치, 운전양태 등과 같은 기술적 사항에 대한 고려가 필요하였다. 비록 모든 사항들이 각각 일정정도의 영향을 가지고 있으나, 상기의 모든 것들이 수질에 영향을 미쳤으며 수질의 성공적인 개선은 정수장 운전의 모든 부분을 파악할 수 있는 상세한 성능평가를 통하여 가장 잘 달성될 수 있다.

  • PDF