• Title/Summary/Keyword: 수관로

Search Result 856, Processing Time 0.031 seconds

Throughfall, Stemflow and Rainfall Interception Loss in Pinus koraiensis Sieb. et Zucc., Larix Leptolepis (Sieb. et Zucc.) Gordon and Quercus Species Stand at Kwangju-Gun, Kyunggi-Do (경기도(京畿道) 광주(廣州) 지방(地方) 잣나무림, 낙엽송림 및 참나무림에서 수관통과우(樹冠通過雨), 수간류(樹幹流) 및 차단손실(遮斷損失))

  • Lee, Don Koo;Kim, Gab Tae;Joo, Kwang Yeong;Kim, Young Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.2
    • /
    • pp.200-207
    • /
    • 1997
  • The throughfall, stemflow and precipitation interception during the period of May to November 1995 were compared between three stands of Pinus koraiensis, Larix leptolepis and Quercus species stand growing at Kwangju-Gun, Kyunggi-Do. The total amount of precipitation during the period in the study area was 1,821mm, higher than average precipitation. The amount of interception showed 21.8% of the total precipitation in Quercus stand, whereas 15.7 and 19.4 in P. koraiensis and L. leptolepis stands, respectively. Precipitation leached on forest floor was occupied mainly by throughfall for all the stands, and it was specially higher in P. koraiensis stand. The amount of stemflow was appeared higher in Quercus stand(5.0%) than P. koraiensis stand(1.1%) or L. leptolepis stand(1.1%). The relationship between throughfall or stemflow and total precipitation in all the stands were highly significant.

  • PDF

The Study on Tree Vigor of Damaged Forest by Thecodiplosis japonensis Uchida et Inouye (솔잎혹파리 피해임지의 수세변동에 관한 연구)

  • Lee, Chan-Yong;Chae, Hee-Mun;Kim, Jong-Kuk
    • Journal of Forest and Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.34-41
    • /
    • 2000
  • This study investigated tree vigor of damaged forest by Thecodiplosis japonensis Uchida et Inouye. In damaged forest by pine gall midge, the investigation result of damaged rate section (severe, moderate, light) indicated that severe stand showed higher value of electric resistance ($k{\Omega}$) than that of light stand, the investigation result of tree density section(crowed, middle, little) indicated that crowed stand showed higher value of electric resistance than that of little stand (the value of electric resistance at which low reading show high vigor tree and high reading low vigor tree). The crown width and DBH (diameter of breast height) of external factors showed lower value of electric resistance than that of small size. The results of comparative between Crown area and value of electric resistance in each stand were $13.4m^2$ in severe stand, $10.9m^2$ in moderate stand and $7.9m^2$ in light stand. Therefore, the tree which have big crown showed low value of electric resistance (below $15k{\Omega}$)that has high possible of survial.

  • PDF

Heat Transfer Characteristics of 2 t/h-Class Modular Water-Tube-Type Boiler (모듈형 2 t/h급 수관식 보일러의 열전달 특성)

  • Ahn, Joon;Hwang, Sang-Soon;Kim, Jong-Jin;Kang, Sae-Byul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1127-1133
    • /
    • 2012
  • A finned-tube-type evaporator module has been proposed for a 2 t/h-class water-tube-type industrial boiler with multiple burners. The geometry of the fins was changed at each module to equalize the evaporation. The modules were designed by considering the energy balance at each row rather than by following a conventional bulk design procedure. The designed module was built into a 2 t/h-class water-tube-type boiler, and its performance was tested. A numerical simulation was also conducted to evaluate the two- or three-dimensional effects of factors such as the inlet conditions. The numerical simulation also included the conjugate heat transfer problem to predict the fin tip temperature. The heat transfer coefficient with fins is lower than that obtained from the empirical correlation of a bare tube. The fin tip temperature from CFD is higher than that from the analytical solution.

Index of Optimum Harvest Time as Seasonal Hesperidin Content Changes for Citrus lemon Juice in Plastic Film House (레몬 하우스 재배에 있어 시기별 과즙의 Hesperidin 함량변화에 따른 적정수확 기준)

  • Lee, Kwang Ju;Han, Sang Heon
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.55-59
    • /
    • 2013
  • This study was evaluated that seasonal change of the hesperidin content was in relation to the skin color and weight of fruit in outer or inner side of the canopy, for determine the optimum time and the index of most abundant hesperidin content in lemon fruits juice. The hesperidin content was different with fruit growth and on fruit bearing site of the tree. The fruits of the either side contained the highest hesperidin value at 162 and 176 days after anthesis just after de-greening and the value was highest in the fruits of outer side of the canopy. This time also corresponded to the time just before the cessation of fruit growth. These results suggested that the optimum harvesting period for more hesperidin content was the stage just after de-greening and just before fruit growth cessation.

Analysis of Forest Fuel Quality by Forest Fire Damage (산림연료 특성별 산불피해도 분석)

  • Kwon, Chun-Geun;Lee, Si-Young;Lee, Myung-Woog;Lee, Hae-Pyeong
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.196-196
    • /
    • 2011
  • 산림연료 특성별 산불피해도 분석을 위하여 산불피해의 조사지역은 2009년, 2010년 산불이 발생했던 강원도 고성지역과 양양지역, 강릉지역과 삼척지역을 조사 대상지역으로 선정하였으며, 고성군의 경우 숲구조가 유령림인 활엽수림이 2개소, 칩엽수림 1개소, 장령림인 활엽수림 2개소로 총 5개소, 양양군은 숲구조가 유령림인 침엽수림이 1개소, 장령림 침엽수림 2개소 총 3개소, 삼척시의 경우는 숲구조가 유령림인 침엽수림이 1개소 외 대조구 장령림 침엽수림 1개소, 강릉시의 경우 숲구조가 장령림인 침엽수림이 3개소 총 13개소를 각각 대상지로 선정하였다. 산림연료 특성별 산불피해도를 조사하기 위한 조사지 규모는 $10m{\times}10m$로 하였으며, 현장 조사 항목은 조사지내의 산불피해 상태, 조사지 지형특성으로 나누어 조사를 실시하였다. 산불피해 상태는 산불진행방향, DBH, 총수고, 지하고, 고사여부, 편면연소, 밀도, 수간피해율, 수관피해율 등을 조사하였고, 조사지의 지형특성을 알아보기 위해 조사지의 위치(GPS), 해발고도, 사면방위, 산지경사, 지형을 조사하였다. 현장조사를 위한 조사장비로는 조사지의 지형도, 야장, 디지털 카메라, GPS, 수고측정기, 직경테이프, 캘리퍼, 50m 줄자 2개, 2m 폴대, 클리노메타, 바인더끈 등을 사용하였다. 산불사례 현장조사를 통해 임목고사여부, 편면연소, 수간피해율, 수관피해율 등의 산불피해 특성을 분석한 결과 연료의 특성별 유령림과 장령림의 편면연소율은 유령림은 97.3%, 장령림은 16.5%로 유령림의 편면연소율이 장령림보다 80.8% 더 피해를 받는 것으로 나타났으며, 수관피해율은 유령림은 95.4%, 장령림은 19.9%로 유령림의 수관피해율이 장령림보다 75.5%더 피해를 입은 것으로 조사 되었다. 또한 임목고사율은 유령림은 73.8%, 장령림은 24.5%로 유령림의 임목고사율이 장령림보다 49.3% 더 피해를 받는 것으로 분석 되었다.

  • PDF

Extraction of Street Tree Information Using Airborne LIDAR Data (항공라이다 자료를 이용한 가로수 정보의 추출)

  • Cho, Du Young;Kim, Eui Myoung
    • Spatial Information Research
    • /
    • v.20 no.6
    • /
    • pp.45-57
    • /
    • 2012
  • The street trees in the urban areas provide an comfortable environment to the pedestrians and drivers and play important roles to absorb the carbons. Therefore, it is necessary to acquire and manage efficiently the location, height, and crown width of street trees. This study suggests a methodology to provide quantitative information of the street trees in urban areas including the quantity, location, height, and crown width of the trees. Therefore, it is more appropriate to add functionality of changing size of the crown width of the trees in the method. In addition, the positions of the street trees were selected using the fact that street trees are generally planted along the road in a straight line. An experiment on extracting street trees was conducted in parts of Osan-si, Gyeonggi-do and the suitability of the suggested methodology was evaluated by comparing the results to a 1/1,000 digital map. Through the experimental results, the minimum, maximum, and the root mean square errors of the position of street trees were 0.5m, 1.9m, and approximately ${\pm}0.4m$, respectively.

Changes of Concentration of Al, Mn and Ni in Throughfall, Stemflow and Rainfall (수관통과우, 수간류 및 임외우에서 Al, Mn 및 Ni의 농도 변화)

  • 이총규;김우룡;김종갑
    • The Korean Journal of Ecology
    • /
    • v.22 no.5
    • /
    • pp.295-298
    • /
    • 1999
  • This study was carried out to investigate the changes in concentration of heavy metals in throughfall, stemflow and rainfall at the survey area. The Al concentration of Pinus thunbergii forest was 1.3 times higher than those of Quercus acutissima forest at industrial area, and 2.1 times higher at urban area. The Al concentration of stemflow was 2.3 times and 113 times, 4.8 times and 55 times, respectively, higher than those of throughfall, and rainfall at both industrial and urban area. The Al concentration of rainfall was lower at industrial and urban area. The Mn concentration of Pinus thunbergii forest was 2.4 times higher than those of Quercus acutissima forest at urban area. Heavy metal concentrations in rain water were the higher in stemflow, and in the order of throughfall and rainfall. Seasonal changes of heavy metal concentration were the highest on December at industrial area, and were higher in the order of March>June>August. Seasonal changes were not remarkable at urban area. Heavy metal concentrations were higher in the order of Al>Mn>Ni at industrial area, and Mn>Al>Ni at urban area.

  • PDF