• Title/Summary/Keyword: 송풍량

Search Result 125, Processing Time 0.024 seconds

Thin Layer Drying and Quality Characteristics of Ainsliaea acerifolia Sch. Bip. Using Far Infrared Radiation (원적외선을 이용한 단풍취의 박층 건조 및 품질 특성)

  • Ning, Xiao Feng;Li, He;Kang, Tae Hwan;Lee, Jun Soo;Lee, Jeong Hyun;Ha, Chung Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.884-892
    • /
    • 2014
  • The purpose of this study was to investigate the drying characteristics and drying models of Ainsliaea acerifolia Sch. Bip. using far-infrared thin layer drying. Far-infrared thin layer drying test on Ainsliaea acerifolia Sch. Bip. was conducted at two air velocities of 0.6 and 0.8 m/sec, as well as three drying temperatures of 40, 45, and $50^{\circ}C$ respectively. The drying models were estimated using coefficient of determination and root mean square error. Drying characteristics were analyzed based on factors such as drying rate, leaf color changes, antioxidant activity, and contents of polyphenolics and flavonoids. The results revealed that increases in drying temperature and air velocity caused a reduction in drying time. The Thompson model was considered suitable for thin layer drying using far-infrared radiation for Ainsliaea accerifolia Sch. Bip. Greenness and yellowness values decreased and lightness values increased after far-infrared thin layer drying, and the color difference (${\Delta}E$) values at $40^{\circ}C$ were higher than those at $45^{\circ}C$ and $50^{\circ}C$. The antioxidant properties of Ainsliaea acerifolia Sch. Bip. decreased under all far-infrared thin layer drying conditions, and the highest polyphenolic content (37.9 mg/g), flavonoid content (22.7 mg/g), DPPH radical scavenging activity (32.5), and ABTS radical scavenging activity (31.1) were observed at a drying temperature of $40^{\circ}C$ with an air velocity of 0.8 m/sec.

Prediction of Maximum Fly Ash Conveying Capacity of Fly Ash System in a Power Plant (발전 보일러용 비회 이송설비에서 최대 비회 이송량 예측)

  • Jin, Kyung-Yong;Moon, Yoon-Jae;Lee, Jae-Heon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.11 no.1
    • /
    • pp.50-57
    • /
    • 2015
  • This study presents prediction of maximum fly ash conveying capacity of fly ash system in a power plant. The mixture ratio and pressure drop characteristics of air-fly ash flow in piping system are not well understood due to the complexity of particle motion mechanism. In this paper, the researcher investigated the optimum mixture ratio when the pressure drop of fly ash conveying system is equal to maximum static pressure of displacement fly ash transport blower and the capacity of fly ash transport according to the optimum mixture ratio by experimenting the fly ash conveying system of domestic D coal thermal power plants, which is currently in operation. The experiment results showed that the maximum fly ash conveying capacity of fly ash system were founded under the condition of maximum air volume 5,040 m3/h, static pressure of trip condition 1,163 mmH2O. In addition, it was predicted maximum mixture ratio of the air-fly ash was 8.66 and maximum capacity of fly ash conveying was 52,600 kg/h under these conditions.

  • PDF

Simulation of Rough Rice Drying by Natural Air(I) (자연공기(自然空氣)에 의한 벼건조(乾燥) 시뮤레이션(I))

  • Chang, D.I.;Chung, D.S.;Pfost, H.B.;Calderwood, D.L.
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.1
    • /
    • pp.118-128
    • /
    • 1983
  • Simulation model of natural air grain drying was discussed and modified to predict the changes of grain moisture content and dry matter loss of rough rice drying. The modified simulation model was then validated using actual test data. A series of simulated drying tests using official weather data for 15 years from Beaumont, Texas, was taken to make minimum airflow rate and maximum bed depth of rough rice drying by natural air, under different conditions of initial moisture content of rough rice, airflow rate and harvest date.

  • PDF

A Study of Fan Stall Warning System Motion Characteristics (축류형 송풍기 운전 특성에 관한 연구)

  • Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.191-194
    • /
    • 2006
  • 500MW급 대용량 보일러 통풍계통의 Fan Stall 감시 장치는 Fan 이상 발생시 Fan을 보호하기 위하여 정지시키는 기능을 한다. 그러나 Fan Stall 감시 장치의 빈번한 고장으로 신뢰성이 저하되고 운전에 영향을 미치므로 이것을 DCS Logic으로 구성하여 신뢰성을 향상시켰다.

  • PDF

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

A Study on the Smoldering hazard of Rice bran dust. (쌀겨 분진의 훈소 위험성에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.12-17
    • /
    • 1999
  • We intended to investigate combustion properties of rice bran dust. Combustion properties of h rice bran dust according to size distribution and amount were measured as temperature v variation with time using spontaneous ignition apparatus. Moreover, combustion properties w with blowing or without blowing condition were checked in order to investigate combustion p properties in spontaneous ignition apparatus according to flow condition of air. A As the mass and size of rice bran dust was increased, i띠ti외 smoldering temperature was l lowered. All of combustion forms were smoldering combustion. Initial smold얹ing temperature w was slightly lower with blowing condition than without blowing condition in spontaneous i ignition apparatus, which condition made heating value high.

  • PDF

Development of the Design Technology for the Pressurization Equipments of High Speed Train (고속전철용 압력완화장치 설계기술 개발)

  • Yeom, Han-Gil;Park, Seong-Je;Go, Deuk-Yong
    • 연구논문집
    • /
    • s.28
    • /
    • pp.21-37
    • /
    • 1998
  • Atmospheric pressure in a tunnel rises in proportion to the square of train’s speed as it enters a tunnel. This pressure difference propagates into the train and cause aural discomfort to the passengers. In order to alleviate the aural discomfort of them. a new ventilation system has been designed and tested. This system controls the charged and discharged by flow rate by detecting the air pressure generated outside and inside of the train. Test to confirm the fundamental performance of the system was carried out. Consequently, this system was found to be able to alleviate the aural discomfort effectively. Application of the system to TGV-K running in the speed range of 350km/h is considered to have good propospect.

  • PDF

The characteristics of deep slot outside rotor type IM (외측 회전형 심구형 유도전동기의 특성)

  • 안병원;박영산;노영오;배철오
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.547-552
    • /
    • 2000
  • This paper presents a developed squirrel cage induction motor for axial flow In. Nearly all of the induction motors for fan consists of two parts, rotor and stator, and the position of rotor is located inside of stator. This construction restricts the air flow rate, otherwise requires bending duct. But developed squirrel cage induction motor for axial flow fan exchanged the position each other. So, we can reduce the weight and size about 30%, and there are no bending duct to locate the fan motor.

  • PDF

Development of The System of Clearing Static Electricity with A Fan in the VLSI Device (초고밀도집적반도체 장비의 송풍형 정전기 제거 장치 개발)

  • Yi, Chong-Ho;Jun, Sung-Ho
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.26-32
    • /
    • 2009
  • The reason of the contamination in the VLSI industry is the electric charge of the wafer itself. We develop the corona discharged system of clearing static electricity with a fan. This system has automatic cleaner of discharging electrode, check the state of jot control a suitable mount of discharged ion, and monitor all state using Zigbee communication module.

Effect of Air Flow on Chemical Properties of Cured Leaves in Bulk Curing Process (황색종 Bulk건조과정의 송풍량과 건조엽의 화학성분 특성)

  • 이철환;진정의
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.2
    • /
    • pp.182-187
    • /
    • 1999
  • A bulk curing experiment was carried out to evaluate the effect of air flow reduction in the bulk barn from color fixing stage in the chemical properties of cured leaves, The air flow was controlled by reducing air velocity of a blower from 0.3m/sec to 0.2m/sec using a boltage regulator(Slidac). The bulk curing before color fixing stage was processed in the conventional curing method. Reduction of air circulation in bulk barn did not affected so much on change of the contents of the main chemical components in cured leaved, such as nicotine, total sugar, total nitrogen, petroleum ether extract, and organic acids. Only a slight increase in essential oil contents, such as solanone, damascenone, damascone, $\beta$-ionone, and megastigmatrienone isomer, could be observed in leaves cured in the reduced air flow.

  • PDF