• 제목/요약/키워드: 송일근

검색결과 153건 처리시간 0.023초

Insulation Diagnostics of Power Cables and Application to Real Distribution System (케이블 절연열화진단과 실 계통 적용)

  • Yi, Dong-Young;Kim, Ju-Yong;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1569-1571
    • /
    • 1999
  • In this work, we have performed the application experiment for real distribution line to diagnose the underground power cables using DC voltage decay measurement system. We have also performed the Isothermal Relaxation Current test for the same distribution line using KDA-l. We could confirmed possibility of grading the insulation aging state of underground power cables. Therefore, we conclude that it is possible to apply DC voltage decay method to the real distribution line.

  • PDF

A Basic Study on Detection of Internal Defects in Distribution Cable Splices (배전용 전력 케이블 접속재의 내부고장 검출에 관한 기초연구)

  • 박치영;진상범;곽희로;김상준;송일근;권동진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.122-124
    • /
    • 1996
  • This paper describes a diagnosis of distribution cable splices by analysis of ultrasonic signals which are generated by partial discharge. A method of ultrasonic signal was used to detect internal defects in distribution cable splices. It is possible that analysis of ultrasonic signal predicts failure by partial discharge generated in distribution cable splices.

  • PDF

Performance Test and Design of Distribution FRP Pole (배전용 FRP 전주 설계 및 성능시험)

  • 한동희;조한구;박기호;송일근;이웅선
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.295-298
    • /
    • 2001
  • This paper presents mechanical properties and weatherability of FRP pole used for a distribution line about high strength and good insulation properties. The experiment strength obtained in cantilever beam test are comparable to ES standards. The environmental factors, such as elevated temperatures, high humidity, and corrosive fluids, and ultraviolet(UV) rays, influence on the performance of Polymeric matrix composite.

  • PDF

Estimation of EPDM Insulator in Distribution Line Using PD Measurement (PD 측정을 이용한 배전용 EPDM애자의 성능평가)

  • 송일근;임장섭;이형구;천종욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 1998
  • Many researchers make efforts to develop an effective material with anti-degradation property. Specially, the porcelain type insulator is required exchanging to polymer insulator acceding to the environmental consideration In this paper, we have developed the estimation system using the PD testing. The approach of PD has been very successful applied to the various practical insulator.

  • PDF

Estimation of EPDM Insulator in Distribution Line Using PO and SO Measurement (PD 및 SD를 이용한 배전용 EPDM애자의 절연성평가)

  • Lim, Jang-Seob;Song, Il-Keun;Lee, Hyung-Gu;Cheon, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.973-975
    • /
    • 1998
  • Many researchers make efforts to develop an effective material with anti-degradation property. Specially, the porcelain type insulator is required exchanging to polymer insulator according to the environmental consideration. In this paper, we have developed the estimation system using the PD & SD testing. Those approach has been very successful applied to the various practical insulator.

  • PDF

Field Application of Recycled Aluminum Wires (재생 ACSR 전선의 실계통 적용)

  • Kim, Ju-Yong;Kim, Sang-Joon;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1396-1398
    • /
    • 1997
  • This paper presents experimental results on the recycling aluminum wires used in the actual field. Several testings were carried out with the recycled aluminum wires to prove that they are reusable. Mechanical, electrical and oxidation properties of recycled and new ACSR $160\;mm^2$ were campared after 7.5 year service aging at the salt comtaminated areas of Korean peninsular.

  • PDF

향후 우리나라의 2차 배전전압

  • 홍순학;장정태;송일근;김경화
    • 전기의세계
    • /
    • 제42권1호
    • /
    • pp.12-20
    • /
    • 1993
  • 본고에서는 언급한 바와 같이 각 나라의 전기방식은 단상 3선식과 4선식이 대부분임을 알 수 있으며, 우리나라의 경우 부하특성은 동력수용이 급증에 따른 부하의 고밀도화로 인한 3상 4선식 220/380-Y 공급이 증가 추세에 있다. 한편, 수요밀도가 높은 단상 2선식 공급지역도 부하가 증가됨에 따라 공급능력의 한계성 도달이 예상되고 단상 3선식 110/220V 지역 역시 공급능력의 한계성 도달이 예상되는 바, 단상3선식 220/440V(440V는 Floating) 승압의 필요성이 요구되고 있다.

  • PDF

Fractal Application of EPDM Insulator Using Surface Di (SD를 이용한 EPDM애자의 프랙탈 응용)

  • 임장섭;김상준;송일근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.410-413
    • /
    • 1999
  • Many researcher make efforts to develop an effective tracking method of accellatinn combined with the field simulation in actual system. Specially, the procelain type insulator is required exchanging to EPDM/SIR polymer insulator according to the recently environmental consideration. In this paper, we have developed the estimation system using the SD testing and the fractal mathematics. Those approach has been very successful to relative applied to the various parctical problem

  • PDF

배전용 폴리머 피뢰기의 장기 신뢰성 평가 기술

  • 권태호;송일근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제18권3호
    • /
    • pp.44-51
    • /
    • 2004
  • 오늘날 대부분의 에너지를 전기에 의존함에 따라 전력사용이 급증하고 부하가 대용량화되어 및 정적 전력공급이 중요한 문제로 대두되었다. 이러한 추세에 따라 송ㆍ배전 설비도 점차 대용량화 및 고전압화 되고 신뢰성을 요구하게 되며, 각종 배전 설비의 제조기술이 더욱 복합 다양하게 발전하고 있다. 그 중 전력계통에서 뇌 혹은 개폐서지 등의 과전압을 흡수ㆍ억제하여, 전력설비와 계통보호를 위해 설치하는 것이 피뢰기이다. 따라서 어떻게 과전압을 낮게 억제할 수 있을까 하는 것이 피뢰기의 가장 중요한 성능이라고 말할 수 있다. (중략)

  • PDF

A Study on the Dielectric Properties of Lightening Arrester used for Distribution Line (배전용 피뢰기의 유전특성에 관한 연구)

  • Kim, Chan-Young;Kim, Ju-Yong;Song, Il-Keun;Lee, Byoung-Sun;Han, Yong-Heui
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1642-1644
    • /
    • 1999
  • This paper provides the results of dielectric properties for aged or controlled lightening arresters. The aged lightening arresters were used for five years in distribution line. The leakage current of lightening arresters and elements was measured to confirm whether the lightening arrester was deteriorated or not. The microstructure was also investigated to determine the size of grain and grain boundary. The dielectric properties of aged lightening arresters were compared to those of controlled lightening arresters. The dielectric constant and the tan${\delta}$ of aged lightening arrester were larger than those of controlled one, resulting from accelerated aging due to the thin grain boundary.

  • PDF