• Title/Summary/Keyword: 손 선량

Search Result 65, Processing Time 0.023 seconds

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

말단선량계의 광자에 대한 선량환산인자의 이론적 계산

  • 김광표;이원근;이상윤;윤석철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.883-888
    • /
    • 1995
  • 본 연구에서 말단선량계에 대한 선량평가시 선량환산인자를 산출하기 위해 1995년의 ANSI N13.32 기준인 “말단선량계의 성능평가를 위한 기준”에서 제안된 기준 팬덤을 가지고 MCNP 전산코드를 이용하여 커마근사법에 의해 수행하였다. ANSI N13.32의 기준팬텀은 손·발 그리고 손가락을 대표하는 원통형으로서 특히 손·발 팬텀에 대해서는 뼈등가물질로 알루미늄을 삽입한 것을 제안함에 따라 본 계산 목적을 위하여 팬텀설계를 똑같이 모사하였으며 사용된 광자빔 에너지는 20keV에서부터 1.5MeV에 걸쳐 14개의 단일에너지를 선택하여 수행하였다. 본 연구에서 전산수행한 결과를 ANSI N13.32의 실험적 결과와 비교해 볼 때 50keV에서부터 1.5 MeV까지의 에너지 영역에서는 최대오차 6% 이내에서 거의 일치함을 보였다.

  • PDF

A Study of Radiation Dose Reduction using Bolus in Medical Radiation Exam (볼루스를 이용한 방사선영상검사 피폭선량저감 연구)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.1001-1007
    • /
    • 2023
  • Dose limits are not applied to medical radiation exposure therefore justification and optimization should be essential for protecting radiation. This study explores methods to reduce exposure dose undergoing general radiation exam by bolus(tissue equivalent material) with keeping image quality. Hand PA projection with 50 kVp, 5 mAs, SID 100 cm, and 8×10 inch is referred by covered bolus of thickness 0, 3, 5, 8, and 10 mm for evaluation entrance dose and SNR. The entrance dose (μGy) to the hand by bolus thickness was 125.41±0.288, 106.85±0.255, 104.97±0.221, 91.68±0.299, and 90.94±0.106 showing a significant reduction in radiation exposure depending on if the bolus was used and bolus thickness. The SNR of the image was 13.997, 13.906, 12.240, 12.538, and 12.548 at each bolus thickness, showing no significant difference. It was confirmed that if appropriate thickness and size of bolus is used depending on the type of radiological imaging exam and the body site, a significant radiation dose reduction effect can be achieved without deteriorating image quality.

Relationship between the Distribution of Space doses in X-ray Rooms and the "Inverse Square Law of Distance" (X선 촬영실 내 공간선량의 분포와 거리 역자승 법칙과의 관련성)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.301-307
    • /
    • 2013
  • In the present study, space doses generated during X-ray radiography of hand, head, and abdomen, etc. were examined and whether the intensity of space doses of scattering rays is attenuated by the "inverse square law of distance" was figured out. First, the space doses of X-ray with small amounts of generated scattering rays such as hand radiography were mostly attenuated by the "inverse square law of distance" and were not detected at all at a distance of 2m. Second, the space doses of X-ray with large amounts of generated scattering rays such as head or abdomen radiography attenuated in higher rates than the rates under the "inverse square law of distance" at distances ranging from 30cm to 1m from the center of the irradiation field and were attenuated by the "inverse square law of distance" at distances ranging from 1m to 2m. Therefore, in X-ray rooms, the subject should be at least 2m away from the center of the irradiation field in the case of hand radiography and X-ray exposure prevention actions using protective devices are required in the entire spaces of the X-ray rooms in the case of head or abdomen radiography.

A Dosimeter System using a short distance radio communication (근거리 무선 통신을 이용한 선량계 구현)

  • Seo, Yong-Chil;Son, Jong-Dae;Lee, Heung-Ho;Kim, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.571-573
    • /
    • 2004
  • 본 논문에서는 휴대용 선량계 시스템에 거리 무선 통신 방식중 Bluetooth를 이용하여 선량계를 구현한 것에 대해 논하였다. 휴대용 선량계란 감마선과 속중성자 및 열중성자를 현장에서 실시간으로 측정 할 수 있는 기기이다. 휴대용 선량계는 선랑계의 소형화를 위해 모듈별로 구성하여 공간의 최적화를 취하였다. 모듈의 구성은 시스템의 전반적인 제어를 하는 CPU부 센서로부터 측정한 데이터를 처리하는 신호처리부 방사선량을 측정하는 센서부로 구성되어졌다. 센서 모들의 PIN 다이오드와 MODFET 센서를 이용하여 감마선, 속중성자, 열중성자를 측정한다. 휴대용 선량계를 관리하고 측정한 데이터의 백업 및 분석을 위하여 PC용 관리프로그램과 근거리 무선 통신(Bluetooth)을 사용하여 통신하도록 만들어 사용하였다. 측정 지역의 방사선량을 휴대용 선량계로 측정하여 PC용 관리프로그램에서 실시간으로 방사선량을 확인 할 수 있다.

  • PDF

A Dosimeter System using Bluetooth (블루투스 통신을 이용한 선량계 시스템 구현)

  • Son, Jong-Dae;Lee, Nam-Ho;Kim, Seung-Ho;Lee, Hung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2616-2618
    • /
    • 2004
  • 본 논문에서는 휴대용 선량계 시스템에 대해 논하였다. 휴대용 선량계는 감마선과 속중성자 및 열중성자를 현장에서 실시간으로 측정 할 수 있는 휴대용 선량계이다. 선량계는 선량계의 소형화를 위해 모듈별로 구성하여 공간의 최적화를 취하였다. 모듈의 구성은 시스템의 전반적인 제어를 하는 CPU부 센서로부터 측정한 데이터를 처리하는 신호처리부 방사선량을 측정하는 센서부로 구성되어졌다. 센서 모듈의 PIN 다이오드와 MODFET 센서를 이용하여 감마선, 속중성자, 열중성자를 측정한다. 휴대용 선량계를 관리하고 측정한 데이터의 백업 및 분석을 위하여 PC용 관리프로그램과 블루투스 통신을 사용하여 통신하도록 만들어 사용하였다. 측정 지역의 방사선량을 휴대용 선량계로 측정하여 PC용 관리프로그램에서 방사선량을 확인 할 수 있다.

  • PDF

Development of Personal Dosimeter (개인 피폭선량 측정 시스템 개발)

  • Kwon, S.G.;Yi, U.K.;Lim, Hun;Sohn, C.H.;Kim, J.S.;Lee, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.724-726
    • /
    • 2000
  • 일반적으로 개인방사선감시에 열형광선량계와 필름배지가 공식 개인선량계로 이용되어 왔고 현재까지도 가장 보편적으로 사용되고 있다. 하지만 최근에는 Si 다이오드와 G-M관을 이용한 능동형 개인피폭선량계가 개발 보급되고 있다. 개인피폭선량계는 누적선량을 실시간으로 알 수 있다는 장점을 가지고 있을 뿐만 아니라 선량률에 관한 정보도 제공하므로 높은 비용부담에도 불구하고 피폭관리의 용이함으로 인해 주목을 받고 있다. 따라서 본 연구는 수입에 의존해 온 개인피폭선량계를 대체하기 위해 반도체형 방사선 검출기를 설계하여 다양한 서비스를 부가할 수 있는 개인피폭선량계를 자체개발고, 선량계의 운영 및 판독을 위한 장치를 개발하였다.

  • PDF

청국장과 된장의 생리활성효과에 미치는 감마선의 영향

  • 손준호
    • Food Industry
    • /
    • s.168
    • /
    • pp.28-31
    • /
    • 2002
  • 한국산 콩 발효식품인 청국장과 된장의 생리활성효과에 대한 감마선의 영향을 살펴보았다. 청국장과 된장은 시중에서 구입하였으며 5,10,20 kGy의 선량으로 조사하였다. 생리활성효과로 angiotensin converting enzyme inhibition, xanthine oxidase inhibition, tyrosinase inhibition과 전자공여능을 살펴본 결과 10 kGy 보다 낮은 조사선량에서는 어떠한 영향도 끼치지 않는 것으로 나타났다.

  • PDF