• Title/Summary/Keyword: 손 고정장치

Search Result 23, Processing Time 0.028 seconds

CRANIUM-ORIENTED MAXILA AND CONDYLE POSITIONING DEVICE (두개골에 기준을 둔 상악 및 과두 고정용 장치)

  • Lee, Won-Hak;Hong, Kwang-Jin;Lee, Jeong-Gu;Sohn, Hong-Bum;Cho, Yun-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1999
  • Special attention should be directed toward the preservation of preoperative condylar position during orthognathic surgery because their positional change may leads to postoperative skeletal relapse as well as TM joint problem. Various condylar positioning devices, therefore, have been introduced and utilized in orthognathic surgery. Even though most of them provided us with improvement of surgical results, we also found some problems including limited indication, etc. For more accurately repositioning the maxilla and the mandible and its wide versatility, a newly designed maxilla and condylar positioning device based on the fixed part of cranium is introduced.

  • PDF

Semi-Fixed Lip Bumper in Lesch-Nyhan Syndrome: An Interim Treatment Modality (반 고정식 립 범퍼를 이용한 Lesch-Nyhan 증후군 환아의 자해습관 차단)

  • Lee, Junhee;Lee, Eungyung;Shin, Jonghyun;Kim, Shin;Jeong, Taesung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.93-98
    • /
    • 2020
  • Lesch-Nyhan syndrome is a rare X-linked, recessively inherited disorder of purine metabolism, caused by complete absence of the enzyme hypoxanthine-guanine phosphoribosyl transferase. This syndrome is characterized by 3 major features: neurological dysfunction, hyperuricemia, and cognitive and behavioral disturbances (e.g., self-mutilation, which begins at 2 to 3 years of age). Uncontrollable self-mutilation begins with biting of the perioral tissues and extends into patterns such as finger biting and head hitting. This report describes the case of a 31-month-old boy who was diagnosed with Lesch-Nyhan syndrome with severe lip injuries caused by self-mutilative behaviors. The behaviors were blocked with a semi-fixed lip bumper for a short period. The device was applied to the patient on the day of the visit without the requirement for an oral impression. It was easy to manage oral hygiene and adjust the device because it was detachable by clinicians and guardians. Therefore, a semi-fixed lip bumper may be useful as an interim appliance to block selfmutilative behaviors in children with Lesch-Nyhan syndrome.

Precise Control of Nutrient Solution and Analysis of Ionic Contribution to EC Reading (양액의 정밀 제어 및 이온의 EC 기여도 분석)

  • Son, Jung-Eek
    • Horticultural Science & Technology
    • /
    • v.16 no.3
    • /
    • pp.352-354
    • /
    • 1998
  • A soilless culture system with the precise control of nutrient solution was developed and the time changes of ionic contribution to EC reading was analyzed. The measuring device designed was able to wash electrodes cleanly and to measure the pH and EC of nutrient solution stably in the box. The nutrient supply system using metering device was also able to control the EC and pH within ${\pm}0.05mS/cm$ and ${\pm}0.05$, respectively. Under the EC control, activity coefficients of all ions decreased with time as ionic concentrations of $SO_4$, Mg and Ca increased due to the selective nutrient absorption by plants. Time changes of ionic contribution to EC reading could be calculated using equivalent ionic conductivities and activity coefficients obtained by numerical analysis.

  • PDF

Development of Inspection System for Transparent Pattern of the Electromagnetic Resonance Pen (전자펜 입력용 투명패턴 검사장치 개발)

  • Ryu, Young Kee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.640-645
    • /
    • 2020
  • To produce an input device stably using the transparent electromagnetic pattern of an electromagnetic induction method, pattern inspection is required in advance in the production process. Various methods of inspecting the capacitive pattern for hand-touch have been proposed, but it is difficult to find the related technical data for the pattern inspection method of the transparent electromagnetic induction method. In this study, to develop an inspection system for a fused electromagnetic resonance pen sensor with a copper-etched metal mesh pattern, an inspection algorithm and method for measuring the antenna impedance inside the sensor was proposed by measuring only the exposed FPCB connector. The proposed method was configured as a control board consisting of a microprocessor that forms a loop between specific channels according to the command of a computer, a computer-controlled by the Windows program, an LCR meter measuring the impedance between specific channels, and transmitting the measurement results back to the computer. An evaluation of the proposed system and measurements of nine specimens showed that it could detect the defects of the sensor used in the actual product.

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF

A Study on Detoxication of Coal Briquette by Additives (첨가제에 의한 연탄제독에 관한 연구)

  • Chang Tuwon;Young Sun Uh;Youn Soo Sohn
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.118-125
    • /
    • 1986
  • A small scale combustion unit was built to evaluate the CO suppression effects by various chemical additives added to coal briquettes. Among the additives tested comprising various transition metal compounds with catalytic activities, natural minerals and oxidizing agents, the copper component has shown the best CO suppression effect, and in particular, copper oxide dispersed on porous supports such as ${\gamma}-Al_2O_3$ was most effective. For instance, 0.5% of copper added to coal briquettes in this way bas exhibited 1.4 % CO in the combustion gas at the ignition and beginning stage of combustion and 0.3 % CO at the final stage. The effects of calcium compounds on the fixation of sulfur in coal were also evaluated to reduce the contents of sulfur compounds in the combustion gases.

  • PDF

Design of kitchen cabinet using complex link mechanism (복합 링크기구를 이용한 주방 상부장 설계)

  • Geon-Hyeok Lim;Kibum Shim;Hoon Shim;Jiwon Jang;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.429-434
    • /
    • 2023
  • Kitchen cabinets are essential furniture for storing the kitchen tools, but their high installed location makes it difficult for users to access the upper of the cabinets. Therefore, in this paper, we propose a new type of kitchen cabinet that allows users to easily take out or store items by adding new height adjustment features while maintaining the function of the existing cabinet. For convenience and safety, an appropriate complex link mechanism is designed so that the selected floor, not the entire cabinet, can come down to a desired height with one operation. Moreover, the optimal descent path is set to prevent the floor tilting or interfloor interference during descent, and appropriate link shapes, lengths, and joint types are selected to implement it. FEA analysis is performed to ensure that the stretched complex linkage can support the load of the stored items and the feasibility of the height adjustable kitchen cabinet is verified through fabrication.

LESCH-NYHAN SYNDROME: A CASE REPORT (Lesch-Nyhan syndrome: 증례보고)

  • Kim, Myoung-Gook;Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.284-289
    • /
    • 2011
  • Lesch-Nyhan syndrome is a disease caused by metabolic disorder of purine. General muscle stiffness and hyposomia are shown from infancy and symptoms can include involuntary or irregular movements of arms and legs, mental retardation, and compulsive self-mutilating behaviors. Self-mutilating behaviors begin at approximately the first year or sometimes at late teens. The patients bite their lips, especially lower lip, tongue, buccal mucosa, hands and fingers. Tongue and lips can be injured or mutilated in severe cases. As the patient gets older, self-mutilating behaviors become more serious and extensive and secondary infection of injured areas is possible. Periodic soft tissue damage due to self-mutilating may evolve to cancer. Medical treatment, appliance treatment, extraction of tooth and surgical operation was attempted to control self-mutilaing behaviors. We hereby report the case of child Lesch-Nyhan syndrome patient who has self-inflicted labial damage as chief complaint. When patient was treated with conservate therapy, such as removable or fixed appliance, the frequency of labial damage could be subdued and yielded favorable results.

THE STDUY OF THE RELAPSE OF HARD AND SOFT TISSUE AFTER MAXILLARY PROTRACTION (상악골 전방견인 후 경조직과 연조직의 재발에 관한 연구)

  • Yang, Jun-Ho;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.373-389
    • /
    • 1997
  • The purpose of this stdudy was to evaluate the effect of maxillary protraction and the relapse of hard and soft tissue after maxillary protraction. For this study 29 patients who were treated with maxillary protractor and labiolingual archwire were selected. Their mean age was 9 years 4 months and mean treatment period was 8.5 months. Lateral cephalograms were taken at pretreatment, immediately after treatment and one to three months after removal of the maxillary protractor. They were traced on skeletodental and soft tissue structures based on Burstone's analysis and analyzed by Quick-Ceph Image Digitizing System(ORTHODONTIC PROCESSING). The mean and standard deviation between pretreatment and posttreatment and between posttreatment and retention period for each cephalometric variable were calculated. Student t-test was used to determine the statistical significance of the changes in each variable. Correlation coefficients between hard tissue and soft tissue were used to determine interrelationship. The results were as follows. 1. After maxillayy protraction, the maxilla and maxillary dentition moved antero-inferiorly, the mandibld and mandibular dentition moved postero-interiorly and palatal plane rotated antero-superiorly by $0.59^{\circ}$. 2. After maxillary protraction, the soft tissue of upper lip moved antero-interiorly with the movement of hard tissue but the antero-posterior position of lower lip was stable in spite of the change of hard tissue. The thickness of upper lip was decreased and that of lower lip was increased after maxillary Protraction. 3. During the retention period, the position of jaws was relatively stable but upper and lower anterior teeth and antero-superiorly rotated palatal plane relapsed to original position. 4. During the retention period, the soft tissue of lips was stable antero-posteriorly and moved mote inferiorly than posttreatment. 5. The correlation coefficients between the postion of upper and lower incisal edge and that position of lips were high, especially in horizontal change.

  • PDF

Oral rehabilitation with magnetic overdentures for an old patient with complex systemic diseases (복합적인 전신질환이 있는 안면마비 환자의 양악 자성 피개의치 수복 증례)

  • Ko, Eunjin;Ahn, Sujin;Lee, Sukwon;Park, Sujung;Lee, Richard Sungbok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.150-156
    • /
    • 2015
  • As dental implant treatment becomes popular for both partial and complete edentulous patients, old people with complex systemic diseases also tend to prefer implant-assisted-overdenture or implant-supported-fixed prostheses to conventional complete denture. In this case, 77-year-old female who was on medication for hypertension and osteoporosis and paralyzed on right side due to stroke visited for implant-assisted-overdenture on lower jaw. After oral and radiographic examination, root-assisted magnet overdenture on upper jaw and implant-assisted magnet overdenture on lower jaw are planned. Consequently, overdentures using self-adjusting magnetic attachment(SA) system on both jaws resulted in recovering satisfying function and retention, which is enable to insert and remove with only one hand.