• 제목/요약/키워드: 손목보조기

Search Result 7, Processing Time 0.033 seconds

Finite Element Analysis of Wrist Orthosis with 3D Printing (3D 프린트를 통해 제작된 손목 보조기의 유한요소해석)

  • Choi, Hyeun-Woo;Kang, Inyeong;Noh, Gunwoo;Seo, Anna;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this study was to manufacture a wrist brace using a computerized tomography system, clinical design software (MediACE 3D Program), and 3D printer. After acquiring the Dicom file of the upper limb with a computed tomography, the wrist brace was designed using the MediACE 3D Program to create a "stereolithography" file. The designed wrist brace was printed using a 3D printer. To verify the effectiveness of wrist assistive device manufactured by 3D printing technology, the stress distribution of the pressure and orthosis applied to bone and skin is represented by finite element analysis. It is expected that the wrist brace can be manufactured by reinforcing the part where the damage caused by pressure and breakage of the brace frequently occurs with the result of finite element analysis when producing the wrist brace.

Finite Element Analysis(fem) of The Fixed Position of the Velcro Band for the 3D Print Wrist Brace made using the Dicom File (CT Dicom 파일을 이용하여 제작한 3D Print 손목보호대용 Velcro band 고정위치의 유한요소해석(FEM))

  • Choi, Hyeun-Woo;Seo, An-Na;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.585-590
    • /
    • 2021
  • Wrist braces are being used for patients with wrist trauma. Recently, many studies have been conducted to manufacture custom wrist braces using 3D printing technology. Such 3D printing customized orthosis has the advantage of reflecting various factors such as reflecting different shapes for each individual and securing breathability. In this paper, the stress on the orthosis by the number and position of Velcro bands that should be considered when manufacturing a 3D printing custom wrist brace was analyzed. For customized orthosis, 3D modeling of the bone and skin regions was performed using an automatic design software (Reconeasy 3D, Seeann Solution) based on CT images. Based on the 3D skin area, a wrist orthosis design was applied to suit each treatment purpose. And, for the elasticity of the brace, a wrist brace was manufactured with an FDM-type 3D printer using TPU material. To evaluate the effectiveness according to the number and position of the Velcro band of the custom 3D printed wrist brace, the stress distribution of the brace was analyzed by the finite element method (FEM). Through the finite element analysis of the wrist orthosis performed in this study, the stress distribution of the orthosis was confirmed, and the number and position of the orthosis production and Velcro bands could be confirmed. These experimental results will help provide quality treatment to patients.

Design of Upper-limb Rehabilitation Device with Power-assist Function for Stroke Survivals (뇌졸중 환자용 동력보조형 상지재활훈련기의 설계)

  • Bae, J.H.;Moon, I.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 2011
  • In this paper, we proposed a design of upper-limb rehabilitation device with power-assist function for stroke survivals. The designed upper-limb rehabilitation device has three degrees of freedom; it is possible to perform flexion and extension motions of wrist, index finger and the other fingers except the thumb independently. The power-assist for wrist motion is performed by a pneumatic double-acting cylinder, but the fingers are actuated by electrical linear actuators to assist motions. A prototype upper-limb rehabilitation device and its controller were implemented. The position controller showed 0.8 mm errors in the steady-state. Experimental results showed that the proposed upper-limb rehabilitation device with power-assist function is feasible.

Stress analysis of plastic hand sprint (플라스틱 손목보조기의 응력 해석 연구)

  • 장대진;이한림;김명회;양현석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.899-902
    • /
    • 2003
  • This study was tested for the bending stress analysis of hand spl int for Hemiplegic Patients. Hemiplegia was represented the stroke and the cerebral palsy. Hand splints of four materials was an Orthoplast hand splint, a Polypropylene hand splint, a Yogips hand splint and an Aluminum hand splint. The Stress Analysis system was made by the electronic oscilloscope, strain gage sensors, amplifier, A/D converter, PC with C program. It will be able to using the important data in spl int design. The results of analysis were obtained various different graphes and maximum data in an Orthoplast hand splint, a Polypropylene hand splint, a Yogips hand splint and an Aluminum hand spl int.

  • PDF

Supplemental Value of the Wrist-Worn Actigraphy in Diagnosing the Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 진단에서 손목부착형 활동기록기의 보조적 진단가치)

  • Im, Mee-Hyang;Shin, Hong-Beom;Lee, Yu-Jin;Lee, Seung-Hi;Won, Chang-Yeon;Lee, Myung-Hee;Lee, Soo-Young;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.1
    • /
    • pp.32-38
    • /
    • 2005
  • Objectives: Obstructive sleep apnea syndrome (OSAS) has drawn increasing attention as medical community has become to be aware of its co-morbidities and complications, especially cardiovascular complications and excessive daytime sleepiness with accident proneness. As of now, polysomnography is the standard tool to diagnose sleep apnea and estimate the treatment validity. However, its being rather expensive and inconvenient, alternate diagnostic tools have been proposed including wrist actigraphy. So far, actigraphies have been adopted usefully to field-survey sleep apnea prevalence. In this study, we attempted in a sleep laboratory setting to assess the supplemental value of actigraphy in diagnosing OSAS. Methods: This study was done at the Division of Sleep Studies, the Seoul National University Hospital. Thirty-seven clinically suspected cases of OSAS underwent the one-night polysomnography, simultaneously wearing an actigraphy on non-dominant wrist. We analyzed the data of 27 polysomnographically-proven OSAS patients (male:female 20: 7;age $47.6{\pm}12.9$ years old;age range 23 to 72 years) with no other sleep disorders. We calculated RDI (respiratory disturbance index) from the polysomnography data and FI (fragmentation index) from the actigraphy data. Pearson correlation was calculated in order to compare FI with RDI and to evaluate the supplemental diagnostic value of the actigraphy. Results: Mean total sleep time on polysomnography was $401.4{\pm}57.8\;min$ (range of 274.0 to 514.1 min). Mean RDI was $21.7{\pm}20.4/hour$. Mean FI was $21.9{\pm}13.0/hour$. RDI and FI showed significant correlation (r=0.55, p<0.01). Conclusions: Wrist actigraphy in OSAS patients generates a comparable outcome to polysomnography, in measuring the nocturnal sleep fragmentation. The actigraphy could be used supplementally in inpatients, outpatients, and field survey subjects, if polysomnography is unavailable or impossible. In follow-ups related with nasal CPAP (continuous positive airway pressure), upper airway surgery, and oral appliance in OSAS patients, the actigraphy might play a more dominant role in the future.

  • PDF

The Effect of Cock-up Splinting on Upper Extremity Muscle Fatigue During Keyboard Typing (손목보조기가 키보드 타이핑작업 시 상지근육 피로도에 미치는 영향)

  • Kim, Min;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jang-Hwan
    • Physical Therapy Korea
    • /
    • v.15 no.2
    • /
    • pp.73-80
    • /
    • 2008
  • With the introduction of the video display terminal (VDT), the efficiency and productivity of work has improved. However, VDT syndrome is threatening the health of workers as a side effect of prolonged use of a VDT. Among various VDT syndromes, the musculoskeletal disorder, especially, the cumulative trauma disorder (CTD) is the common research topic related with upper extremities function. The aim of this study was to investigate the effect of the wrist-hand orthosis (WHO) on fatigue in middle deltoid, anterior deltoid, serratus anterior, and upper trapezius during one-hour computer keyboard typing. Twelve healthy subjects participated in this study. Surface electromyography was used to assess the localized muscle fatigue (LMF), and the LMF was calculated at 10 minutes, 20 minutes, 40 minutes, and 60 minutes in each muscle, with and without the WHO. Data were analyzed by paired t-test with a level of significance of .05. The results of this study are as follows: 1) At 10 minutes, the LMF decreased significantly with applied WHO in the middle deltoid, anterior deltoid, and upper trapezius (p=.001, p=.026, p=.019, respectively). 2) As the computer keyboard typing period increased, there were no significant LMF differences, except for the upper trapezius. Therefore, it can be concluded that the WHO can be applied to decrease the LMF for the initial 10 minute period in the middle deltoid, anterior deltoid, and upper trapezius' but that the long term effect of WHO in reducing the LMF was proven only in upper trapezius during continued computer keyboard typing.

  • PDF

Relationship between Depressive Symptoms and Sleep Parameters in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 환자의 우울증상 정도에 따른 수면 양상)

  • Won, Chang-Yeon;Lee, Seung-Hee;So, Min-Ah;Lee, Jin-Sung;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Objectives: Obstructive sleep apnea syndrome (OSAS) is the most common form of sleep-disordered breathing and often presents with comorbid depressive symptoms. In this study, we evaluated the relationship between depressive symptoms and sleep parameters as measured by nocturnal polysomnography (NPSG) and simultaneous wrist actigraphy. Methods: Two hundred sixty-four subjects with clinically suspected cases of OSAS underwent one-night polysomnography, while simultaneously wearing a wrist actigraphy device. They also completed two questionnaires;the Epworth Sleepiness Scale-Korean version (ESS-K) and the Beck Depression Inventory (BDI). Of the cases studied, 105 subjects were proven by NSPG to have OSAS without other sleep disorders. NPSG and wrist actigraphy data from the subjects were analyzed. Pearson correlation and paired t-test were used in order to evaluate the relationship between depressive symptoms and sleep-parameters. Results: Mean age of the subjects was $46.1{\pm}13.1$ years. Means of the ESS-K score and BDI scores were $10.9{\pm}4.7$ and $12.8{\pm}8.1$, respectively. NPSG sleep parameters significantly differed from those of wrist actigraphy. There was no correlation found between subjects' respiratory disturbance index (RDI) and BDI scores. When directly comparing sleep parameters between subjects who were more depressed versus subjects who were less depressed, both total sleep time and sleep efficiency were decreased in the more depressed. A correlation between RDI and ESS-K scores was also found in the more depressed group. Conclusions: Although our findings suggest that there is no relationship between RDI and depressive symptoms, there are other significant differences in the sleep parameters between subjects who are more depressed versus those without depression. We recommend that patients with depression should also be evaluated for clinical symptoms of OSAS.

  • PDF