• Title/Summary/Keyword: 속응성

Search Result 38, Processing Time 0.022 seconds

A Study of Improvement on the Quickness of Current controller for Permanent Magnet Synchronous Motor (PMSM 전류제어기의 속응성 향상에 관한 연구)

  • Cho, Su-Eog;Lee, Jeong-Hwan;Kim, Cheul-U
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.136-143
    • /
    • 2007
  • A improved current controller with reference modification part that has both fast transient response in transient state and high accuracy in steady state is proposed. In this scheme, a improved reference modification part is used to synchronous frame PI controller for the fast transient state. The transient response of current controller is seriously deteriorated in high back e.m.f.(electromotive force) due to the lack of DC link control voltage. This paper is proposed that the improved reference modification part is compared with voltage limit and reference voltage.

Speed Control of AC Servo Motor with Loads Using Neuro-Fuzzy Controller (뉴로-퍼지 제어기를 이용한 부하를 갖는 교류 서보 전동기의 속도제어)

  • Gang, Yeong-Ho;Kim, Nak-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.8
    • /
    • pp.352-359
    • /
    • 2002
  • A neuro-fuzzy controller has some problems that he difficulty of tuning up the membership function and fuzzy rules, long time of inferencing and defuzzifying compare to PID. Also, the fuzzy controller's own defect as a PD controller has. In this study, it is proposed two methods to solve these problems. The first method is that inner fuzzy rules are tuned up automatically by the back propagation learning according to error patterns. And the second method is a new type defuzzification method that shorten the calculation time of an inferencing and a defuzzifying. In this study, it is designed the new type neuro-fuzzy controller that improves the fast response and the stability of a system by using the proposed methods. And, the designed controller is named EPLNFC(Error pattern Learning Neuro-Fuzzy Controller). To evaluate the fast response and the stability of EPLNFC designed in this study, EPLNFC is applied to a speed control of a DC motor and AC motor.

Design of Continuous-Time System Using Bilinear Transformation (쌍선형 변환에 의한 연속 시간계의 설계)

  • Kim, Sang-Bong;An, Hwi-Ung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.3
    • /
    • pp.137-142
    • /
    • 1989
  • A pole assignment problem in a specified region is solved using a bilinear transformation method. It is well known that the problem designing discrete-time system or vice versa is called redesign problem, But there is not so much study that is cyclic type of design, i.e. from continuous system to discrete system and from the latter to the former system. In this paper, the cyclic type of design for the continuous-time system is proposed using the bilinear transformation. In the view of a pole assignment method with poles in a specified region, it will be possible to design a regulator or a servo system considering damping ratio, stability degree and band with which are resulted to the characteristics of the closed-loop system.

  • PDF

Design of Digital PWM Controller for Voltage Source Inverter (전압형 인버터를 위한 디지털 PWM 제어기 설계)

  • 이성백;이종규;정구철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.3
    • /
    • pp.27-33
    • /
    • 1993
  • This paper presents the &tal controller for driving high frequency voltage fed PWM inverter that carrier frequency is over 2OkHz.We analyzed the conventional PWM to select a proper PWM pattern. as the result, obtained PWM pattern of the controller in which asynchronus staircase sinusoidal waveform is used as reference signal, and variable carrier ratio method was used for PWM control. The PWM controller is designed by fully digital method. Especially, Thk proposed controller is consisted of 8 bit one-chip microprocessor and digital logic. the former is for arithmetic and data processing, and the latter is for PWM pattern synthesis. Therefore, The responsibility and controllability is improved. Also, Data processing capability is improved using proper program to output modulation index with 9 bits. Circuits configuration of digital controller are made up of one chip 8051 and EPLD, and its controllability is tested by operating voltage fed inverter. Harmonics and current waveform is evaluated and analyzed for the voltage fed inverter system.

  • PDF

A Study on Optimal Size Evaluation Model for Large Scale SMES System (저장용 초전도 에너지 저장장치의 최적규모 산정을 위한 투자모형 수립에 관한 연구)

  • 김정훈;김주락;장승찬;임재윤
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.215-222
    • /
    • 1999
  • Integrating energy storage into electlic power system has long been recognized as a way to maximize a utility's g generation and transmission capacity, Electlic power can be stored during off-peak periods and then recovered during p peak conditions to offset the need for larger generation and transmission capacity, Currently large-scale SMES for the p purpose of energystorage which can be also se$\pi$ed by battery storage or flywheel system has been developed, and near f future it will be integrated into power grids, This paper presents an investment analysis on large-scale SMES which c can determine its optimal size in power systems, In operation model. least generation cost for energy storage in SMES a and its mar밍nal capacity cost can be calculated using the discreteness of probability distribution for power availability I Investment decisions are made by the maximum p디nciple and the case study shows the optimal operation and realistic i information on the proper size of large-scale SMES in power systems.

  • PDF

A study on the development of digital AVR for ship and offshore (선박 및 해양플랜트용 디지털 자동전압조정기 개발에 대한 연구)

  • Lee, Jun-Soo;Yun, Kyung-Guk;Kim, Jong-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.39-44
    • /
    • 2016
  • Automated voltage regulators (AVRs) are used on ships and offshore to automatically adjust the voltage based on real-time output voltage readings of the generator engine. Analog-type AVR was previously more commonly used, but is slowly being replaced with digital-type AVR because of increased demands of response time. This study presents a new digital AVR system that contains appropriate features of the AVR with respect to offshore unstable load conditions and poor operating conditions. Furthermore, experiments of load and voltage change prove the excellence of stability and response of the proposed system compared to previous AVR systems. Additionally, an integrated control system for a monitoring the output voltage and field current was developed to easily set the gain value.

A Study on Excitation System for Synchronous Generator Using Two State Three Phase PWM AC/DC Converter (2단 3상 PWM AC/DC 컨버터를 이용한 동기발전기 여자제어시스템)

  • Lee, Sang-Hun;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.96-106
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system. Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system. In the case of diode rectifier system of phase controlled converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, two stage three phase PWM AC/DC converter is studied to solve these problems. The characteristics of a proposed converter reduces the harmonics and reactive power of the distribution line and has fast dynamic response in transient period using boost converter and current control mode buck converts. The proposed method is verified by the computer simulation and experimental results in prototype generation system.

A Study of Improvement on the responsiveness of Digital AVR System (Digital 자동전압조정장치(AVR)의 속응성 향상에 관한 연구)

  • Kim, Song-hyun;Lee, Hyung-ki;Choe, Wook-yeon;An, Young-joo;Kim, Hyun-soo;Kim, Gi-Ryang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.246-247
    • /
    • 2015
  • Type of Automatic Voltage Regulator (AVR) can be divided into Analog and Digital Type. Automatic Voltage Regulator (AVR) of the synchronous generators of the brushless type are to be reduced to the voltage fluctuation on the basis of the total load. The PID control method is a general control technique is commonly widely used. In this study, the control target parameter iPID does not reset the parameters of the controller for the variable (Intelligent PID) using the controller synchronous generator Digital automatic voltage to you like all applied to the adjusting device (AVR) the voltage change is small, improved responsiveness was studied in this controller.

  • PDF